• Title/Summary/Keyword: Relay System

Search Result 1,267, Processing Time 0.026 seconds

Transceiver Design Using Local Channel State Information at Relays for A Multi-Relay Multi-User MIMO Network

  • Cho, Young-Min;Yang, Janghoon;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.11
    • /
    • pp.2616-2635
    • /
    • 2013
  • In this paper, we propose an iterative transceiver design in a multi-relay multi-user multiple-input multiple-output (MIMO) system. The design criterion is to minimize sum mean squared error (SMSE) under relay sum power constraint (RSPC) where only local channel state information (CSI)s are available at relays. Local CSI at a relay is defined as the CSI of the channel between BS and the relay in the $1^{st}$ hop link, and the CSI of the channel between the relay and all users in the $2^{nd}$ hop link. Exploiting BS transmitter structure which is concatenated with block diagonalization (BD) precoder, each relay's precoder can be determined using local CSI at the relay. The proposed scheme is based on sequential iteration of two stages; stage 1 determines BS transmitter and relay precoders jointly with SMSE duality, and stage 2 determines user receivers. We verify that the proposed scheme outperforms simple amplify-and-forward (SAF), minimum mean squared error (MMSE) relay, and an existing good scheme of [13] in terms of both SMSE and sum-rate performances.

Network-Coding Based Two-way Relay Communication Using Adaptive Modulation Sheme (적응형 변조 기법을 이용한 네트워크 부호화 기반 양방향 중계 통신)

  • Lee, Jin-Hee;Kong, Hyung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.147-151
    • /
    • 2010
  • In this paper, we propose network-coding based two-way relay communication using adaptive modulation scheme for satisfying relay QoS(Quality of Service) according to channel environment between user and relay. Two-way relay communication is bidirectional cooperative communication that users exchange own signal with help of relay. Network-coding based two-way relay communication can achieve high throughput compared to conventional scheme through reducing time slots. we propose adaptive M-QAM modulation scheme in network-coding based two-way relay communication for satisfying QoS of relay. Simulation result shows that the proposed scheme satisfies goal QoS of system.

Performance Analysis of Adaptive RS Coverage Extension Scheme for the MMR systems (MMR 시스템을 위한 적응적인 RS 커버리지 확장 기법의 성능 분석)

  • Kim, Seung-Yeon;Kim, Se-Jin;Lee, Hyong-Woo;Ryu, Seung-Wan;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4B
    • /
    • pp.584-591
    • /
    • 2010
  • In this paper, we propose an adaptive Relay Station (RS) coverage extension scheme for the Mobile Multi-hop Relay (MMR) systems. The MMR system with a non-transparent mode RS can be used to extend BS coverage using the remaining capacity of the Base Station(BS). Thus, the call blocking may occur in RSs when calls arrive very often in Multi-hop Relay Base Station (MR-BS). In the proposed scheme, RSs can be connected to the neighbor MMR system as the 2ndtier RSs if the neighbor MMR system services low traffic load when calls are frequently arrived in MR-BS or RSs. By doing so, the MMR system can accept a new call without call blocking. Through numerical results, we demonstrate that the proposed scheme outperforms the conventional MMR system in terms of the throughput and call blocking probability of MMR systems.

Power-limited Cooperative Diversity with Selection Combining in Rayleigh Fading for Wireless Ad-hoc Networks (레일레이 페이딩하에서 무선 ad-hoc 네트워크를 위한 전력제한된 선택결합 협동다이버시티)

  • Kim Nam-Soo;Lee Ye-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.8A
    • /
    • pp.769-774
    • /
    • 2006
  • Based on the performance of a cooperative diversity with selection combining in Rayleigh fading, the power control range of a relay node is investigated. Also the effect of the power-limited relay node to the system performance is investigated. If the average signal-to-noise ratio(SNR) of each signal path is equal, the single relay cooperative diversity is obtained 13.5dB gain at the outage probability of $1{\times}10^{-3}$ in Rayleigh fading. We noticed that the limited power of a relay node severely degrades the system performance. Therefore the node with limited power in ad-hoc network is not recommended as a relay node in cooperative diversity system.

Performance of Downlink with Dual-Hop Communication Systems in Railway Environments (철도환경에서 듀얼홉 통신시스템을 적용한 하향링크 성능)

  • Cho, Woong;Kim, Bum-Gon;Cho, Han-Byeog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • Due to the advantage of communication coverage extension and removement of shadowing area, relay can be applied in various wireless communication systems. In this paper, we analyze performance of downlink with dual-hop communication systems which use a relay in railway environments. We adopted asymmetric communication system which use coherent modulation scheme in base station-relay link and differential modulation scheme in relay-destination link. The performance of communication system is analyzed using symbol error rate, and performance comparison with the systems which adopts fully coherent scheme is studied. We also investigate the performance of system depending on relay distance and energy allocation.

Development of Delta-I ground fault Protective Relaying Scheme for DC Traction Power Supply System (비접지 DC 급전시스템에서의 Delta-I 지락보호계전 시스템)

  • Chung, Sang-Gi;Kwon, Sam-Young;Jung, Ho-Sung;Kim, Ju-Rak
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.529-535
    • /
    • 2006
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot identify the faulted region which causes long traffic delays and safety problem to passengers. A new ground fault protective relay scheme, ${\Delta}I$ ground fault protective relay, that can identify the faulted region is presented in this paper. In ${\Delta}I$ ground fault protective relaying scheme, ground fault is detected by 59, overvoltage relay, which operates ground switch installed between the negative bus and the ground. It preliminarily chooses the faulted feeder after comparing the current increases among feeders and trips the corresponding feeder breaker. After some time delay, it then recloses the breaker if it finds the preselected feeder is not the actual faulted feeder. Whether or not the preselected feeder is the actual faulted feeder is determined by checking the breaker trip status in the neighboring substation in the direction of the tripped breaker. If the corresponding breaker in the neighboring substation is also tripped, it finally judges the preselected feeder is actually a faulted feeder. Otherwise it recloses the tripped breaker. Its algorithms is presented and verified by EMTP simulation.

An Algorithm of Predicting the Zone 3 Trip Time of Distance Relay by using PMU Data when Power Systems Face Cascaded Event on Transmission System (송전 계통의 광역정전 징후 시 PMU 취득 데이터를 이용한 거리계전기 Zone3 동작시간 예측 알고리증)

  • Kim, Jin-Hwan;Lim, Il-Hyung;Lee, Seung-Jae;Choi, Myeon-Song;Kim, Tae-Wan;Lim, Seong-Il;Kim, Sang-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2303-2310
    • /
    • 2009
  • Defense systems are needed to prevent catastrophic failures of a power grid due to cascaded events. Cascaded events can be attributed to improper operations of protective relays. Especially, it is the most dangerous problem that trips of backup relays by overload. In this paper, a new algorithm of predicting Zone 3 acting time of distance relay is proposed using the real time synchronized data from PMUs on the transmission system when the power system is danger. In the proposed, some part of the power system are outage when some unexpected fault in the power system, the algorithm will monitor the impedance locus of distance relay. At this time, if there is a big change of Impedance locus, the algorithm will calculate the Zone 3 acting time of the distance relay by the over load. In the case studies, the estimation and simulation network have been testified and analysed in Matlab Simulink.

Impedance Calculation of an Underground Transmission Cable System Installed with a Sheath Current Reduction Device

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Wang, Xin Heng;Song, Yong Hua
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.236-242
    • /
    • 2004
  • Previous research results indicated that the designed current reduction device could effectively reduce the sheath circulating current and that its RDP protection device could shield it against both fault and lightning strokes. In this paper, cable impedance is analyzed using wavelet analysis and distance relay algorithm following the installation of these devices so that the operation of distance relay can be estimated. The test results confirm that in these devices, the fault inception angle and SVL bonding types have no impact on the change of cable impedance. In other words, the conventional distance relay can be used without a new relay setting. Thus we can finally assert that the designed current reduction device and its protection device are effective and can be safely installed on the cable transmission system without disturbance.

A Simple If In-Phase Combiner and Its Performance for Point-to-Point Radio Relay System with Space Diversity

  • Suh Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The implementation of a simple analog in-phase combiner is presented for a high capacity radio relay system with space diversity. It provides good performance in terms of simple hardware and easy control, and measured results are in good agreement with simulated ones. To suggest practical applications, signatures with/without diversity are measured for STM-1 signal of 64-QAM radio relay system combined with a 13-tap equalizer, and they provided more than 25 dB fade depth at 10$^{-3}$ BER under the frequency selective fading condition.

A Study on the Fault Diagnoais of Protected Facility using Relay Information (보호계전기 정보를 이용한 피보호 설비의 고장진단에 관한 연구)

  • Lee, Tae-Young;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.151-153
    • /
    • 2002
  • This paper proposes a concept for fault diagnosis system based on the relay coordination to deal with unavoidable uncertainties imposed on fault dignosis of substation. This system uses information on the relay setting values and tripped data to identify the faulted element of power system. The proposed concept will be very useful and efficient for substation and control center operator.

  • PDF