• Title/Summary/Keyword: Relative quantification

Search Result 302, Processing Time 0.021 seconds

Simultaneous Quantification of Three Marker Compounds in Samultang by HPLC/DAD (HPLC-DAD를 이용한 사물탕 중 3종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Ma, Jin-Yeul;Lee, Jae-Hoon;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.4
    • /
    • pp.298-302
    • /
    • 2009
  • Samultang is one of traditional medicine composed of Paeonia lactiflora, Angelica gigas, Rehmannia glutinosa and Cnidium officinale. To develop simultaneous determination of paeoniflorin, decursin and 5-HMF in Samultang, a high performance liquid chromatography with diode array detector was used. To separate three marker components, Dionex $C_{18}$ column (5 ${\mu}m$, 120 ${\AA}$, 4.6 mm${\times}$150 mm) was used with a gradient elution system of water and methanol. UV wavelength of detector set at 230 nm and 280 nm. This method was validated by linearity, precision test and recovery test. Calibration curves of three standard components were showed good linear regression ($R^2$>0.9973). LOD and LOQ ranged from 0.08 ${\mu}g$/ml to 0.38 ${\mu}g$/ml and 0.25 ${\mu}g$/ml to 1.16 ${\mu}g$/ml, respectively. The relative standard deviations (RSDs) of data of the inter-day and intra-day experiments were less than 0.54% and 0.89%, respectively. The measured results of recovery test were varied from 93.36 to 107.79 with RSD values 0.01~1.45%. The established method was applied for separation of bio-conversion Samultang sample and compared with control sample.

Determination of the Minimum Instream Flows for the Landscape of Riverside (하천의 경관 유지 수량의 결정)

  • 홍형순;이주헌;정상만
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.6
    • /
    • pp.17-25
    • /
    • 2003
  • The physical components of a river, such as water surface width/river width ratio, water level, and flow velocity vary according to different flowrates. Moreover, the riverside landscapes are greatly affected by the change of physical components of the stream or river. This paper provides an analysis of the influence of changing physical components of a river on the riverside landscape using a survey-based quantification method. The questionnaire was developed based on current literature, and was submitted to 326 people who each visited a representative station along the riverside.This survey was implemented three times at each representative station during periods of different flowrates. The results of this analysis and survey have Produced an understanding of the relationship between the variation of physical components and riverside landscapes. Survey results about the flow comparison are summarized as follows. Viewing riverside landscapes, most respondents are sensitive to the change of the flow velocity and prefer high water levels to low water levels. As a whole, respondents prefer abundant stream flows and moderate flow velocity in which they can perceive the flow of water. The minimum instream flows for riverside landscapes is estimated at each representative station by using a survey-based quantification method, and the estimated results of some representative stations were greater than the mean monthly flow at each station. The result of this analysis shows that establishing minimum instream flows for riverside landscapes is not only a technical problem, but also a legal problem. Therefore, in the to establish the instream flows in a river, the estimated results have to be considered as a relative standard. Regarding the survey results, respondents' satisfaction level didn't show any clear inclination according to the variation of various hydraulic properties. In determining the minimum instream flow using such an inquiry method, the structure of riverside scenery may vary according to the change of seasons or months. Therefore, to determine a consistent general inclination about the flow rate, it is necessary to have more detailed flow rates for each season or month combined with more inquiries.

Evaluation of the Immune-Stimulating Activity of Samul-tang, a Traditional Korean Herbal Medicine, Standardized by HPLC-PDA

  • Seo, Chang-Seob;Ha, Hye-Kyung;Jung, Da-Young;Lee, Ho-Young;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.25-34
    • /
    • 2011
  • Objectives: We performed simultaneous determination of five constituents by HPLC in Samul-tang (SMT). Additionally, we investigated the immune-stimulatory potential of SMT on specific cellular and humoral immune responses in ovalbumin (OVA)-immunized mice. Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 190-400 nm, were used for quantification of the five components of SMT. Mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. C57BL/6 mice were immunized intraperitoneally with OVA/alum ($100{\mu}g/200{\mu}g$) on days 1, 8, and 15. The extract of SMT (1000 mg/kg) was given to mice orally for 21 days (from day 1 to day 21). At day 22, OVA-, lipopolysaccharide (LPS)- and concanavalin A (Con A)-stimulated splenocyte proliferation and OVA-specific and total antibodies were measured in plasma. Results: Calibration curves were acquired with $r^2$>0.9999, and the relative standard deviation (RSD, %) for intra- and inter-day precision were both less than 3.5%. The recovery was in the range of 95.69-115.12%, with an RSD less than 6.0%. The contents of five components in SMT were 1.08-15.30 mg/g. SMT significantly enhanced Con A-induced splenocyte proliferation in OVA-immunized mice (p<0.01). Also, SMT significantly enhanced OVAspecific IgG, IgG1 and total IgM levels in plasma compared with the OVA-immunized group. Conclusions: The established method will be applied for the quantification of major components and immunestimulating activity in OVA-immunized mouse model of SMT.

ESTIMATION OF THE MINIMUM INSTREAM FLOWS FOR THE RIVERLINE AESTHETICS ON THE KEUM RIVER

  • Lee, Joo-Heon;Jeong, Sang-Man;Hong, Il-Pyo;Lee, Eun-Tae
    • Water Engineering Research
    • /
    • v.1 no.4
    • /
    • pp.299-307
    • /
    • 2000
  • The method for estimating the minimum instream flows required for the riverline aesthetics, proposed by the Kim et al.(1996), has been applied to the main channel reach of the Keum river basin in Korea. To determine the minimum instream flows for eight main reaches at Keum river basin, six representative stations have been selected. This paper provides an analysis of influence on the riverline aesthetics, which is affected by change of physical components of river, by using the survey-based quantification method. The developed questionnaire based on the literature, and submitted to the 326 people who visited an each representative station. This surveying had been implemented in three times at each representative station and we had been selected a different flowrate at each implementation. The results of this analysis and survey have produced the relationship between the variation of physical components and riverline aesthetics. Survey results bout the flow comparison are summarized as follows. At the view of riverline aesthetics, most of the respondents re sensitive at the change of the flow velocity and they prefer high water level to low water level. Moreover whole respondents prefer to abundant stream flows and moderate flow velocity. The minimum flows for riverline aesthetics is estimated at each representative station by using the survey-based quantification method and the estimated results of some representative station are greater than mean monthly flow at each station. The result of the analysis appears that establishing minimum instream flows for riverline aesthetics is not only a technical problem but a legal problem. Therefore in the case of establishing the instream flows in the river, the estimated results have to be considered as relative standard.

  • PDF

A Study on Quality evaluation Methodology Establishment of Anti-Virus Software based on the Real Test Environment (리얼 테스트 환경 기반의 안티바이러스 소프트웨어의 품질평가 방법론 정립에 관한 연구)

  • Maeng, Doo-Iyel;Park, Jong-Kae;Kim, Sung-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.3B
    • /
    • pp.440-452
    • /
    • 2010
  • For an evaluation of the software product, the national/international organizations and labs have been studying various methodologies for the quality on the basis of ISO/IEC Quality Assurance System, but they still have many issues in evaluation of the anti-virus software that has special characteristics of complexity. In this paper, to establish a methodology of the quality evaluation for the anti-virus software, fulfilling the requirements more than reasonable level, a process to draw the evaluation items and quantification was established. And the information of weight was objectified by analyzing the relative magnitude between each factors. Based on the defined information (evaluation item, weight), conducting the quality evaluations for 70 kinds of open anti-virus software collected from the portal sites in the real test environment, and as a result of the positive analysis with user's long-term experience, this paper justifies the evaluation item and the weight.

Impact of High-Level Expression of Heterologous Protein on Lactococcus lactis Host

  • Kim, Mina;Jin, Yerin;An, Hyun-Joo;Kim, Jaehan
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.7
    • /
    • pp.1345-1358
    • /
    • 2017
  • The impact of overproduction of a heterologous protein on the metabolic system of host Lactococcus lactis was investigated. The protein expression profiles of L. lactis IL1403 containing two near-identical plasmids that expressed high- and low-level of the green fluorescent protein (GFP) were examined via shotgun proteomics. Analysis of the two strains via high-throughput LC-MS/MS proteomics identified the expression of 294 proteins. The relative amount of each protein in the proteome of both strains was determined by label-free quantification using the spectral counting method. Although expression level of most proteins were similar, several significant alterations in metabolic network were identified in the high GFP-producing strain. These changes include alterations in the pyruvate fermentation pathway, oxidative pentose phosphate pathway, and de novo synthesis pathway for pyrimidine RNA. Expression of enzymes for the synthesis of dTDP-rhamnose and N-acetylglucosamine from glucose was suppressed in the high GFP strain. In addition, enzymes involved in the amino acid synthesis or interconversion pathway were downregulated. The most noticeable changes in the high GFP-producing strain were a 3.4-fold increase in the expression of stress response and chaperone proteins and increase of caseinolytic peptidase family proteins. Characterization of these host expression changes witnessed during overexpression of GFP was might suggested the metabolic requirements and networks that may limit protein expression, and will aid in the future development of lactococcal hosts to produce more heterologous protein.

Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation

  • Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1077-1088
    • /
    • 2018
  • Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.

Body Pressure Distribution and Textile Surface Deformation Measurement for Quantification of Automotive Seat Design Attributes (운전자의 체압 분포 및 시트변형에 대한 정량화 측정시스템)

  • Kwon, Yeong-Eun;Kim, Yun-Young;Lee, Yong-Goo;Lee, Dongkyu;Kwon, Ohwon;Kang, Shin-Won;Lee, Kang-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.397-402
    • /
    • 2018
  • Proper seat design is critical to the safety, comfort, and ergonomics of automotive driver's seats. To ensure effective seat design, quantitative methods should be used to evaluate the characteristics of automotive seats. This paper presents a system that is capable of simultaneously monitoring body pressure distribution and surface deformation in a textile material. In this study, a textile-based capacitive sensor was used to detect the body pressure distribution in an automotive seat. In addition, a strain gauge sensor was used to detect the degree of curvature deformation due to high-pressure points. The textile-based capacitive sensor was fabricated from the conductive fabric and a polyurethane insulator with a high signal-to-noise ratio. The strain gauge sensor was attached on the guiding film to maximize the effect of its deformation due to bending. Ten pressure sensors were placed symmetrically in the hip area and six strain gauge sensors were distributed on both sides of the seat cushion. A readout circuit monitored the absolute and relative values from the sensors in realtime, and the results were displayed as a color map. Moreover, we verified the proposed system for quantifying the body pressure and fabric deformation by studying 18 participants who performed three predefined postures. The proposed system showed desirable results and is expected to improve seat safety and comfort when applied to the design of various seat types. Moreover, the proposed system will provide analytical criteria in the design and durability testing of automotive seats.

Development of an analytical method for the determination of dl-methylephedrine hydrochloride in porcine muscle using liquid chromatography-tandem mass spectrometry (LC-MS/MS를 이용한 돼지 근육조직 중 dl-methylephedrine hydrochloride의 잔류 분석법 개발)

  • Chae, Won-Seok;Kim, Suk;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.4
    • /
    • pp.209-213
    • /
    • 2020
  • This study examined the residue of dl-methylephedrine hydrochloride (MEP) on the muscle of pigs administered orally with MEP 12 g/ton feed for seven consecutive days. Twenty healthy cross swine were administered MEP. Four treated animals were selected arbitrarily to be sacrificed at 1, 2, 3, 4, and 5 days after treatment. MEP residue concentrations in the muscle were determined by liquid chromatography coupled with tandem mass spectrometry. The drug was extracted from muscle samples using 10 mM ammonium formate in acetonitrile followed by clean-up with n-hexane. The analyte was separated on an XBridgeTM hydrophilic interaction liquid chromatography column using 10 mM ammonium formate in deionized distilled water and acetonitrile. The correlation coefficient (R2) of the calibration curve was 0.9974, and the limits of detection and quantification were 0.05 and 0.15 ㎍/kg, respectively. The recoveries at three spiking levels were 94.5-101.2%, and the relative Standard Deviations was less than 4.06%. In the MEP-treated group, MEP residues on one day post-treatment were below the maximum residue limit in the muscle. The developed method is sensitive and reliable for the detection of MEP in porcine muscle tissues. Furthermore, it exhibits low quantification limits for animal-derived food products destined for human consumption.

Comparison of microbial molecular diagnosis efficiency within unstable template metagenomic DNA samples between qRT-PCR and chip-based digital PCR platforms

  • Dongwan Kim;Junhyeon Jeon;Minseo Kim;Jinuk Jeong;Young Mok Heo;Dong-Geol Lee;Dong Keon Yon;Kyudong Han
    • Genomics & Informatics
    • /
    • v.21 no.4
    • /
    • pp.52.1-52.10
    • /
    • 2023
  • Accurate and efficient microbial diagnosis is crucial for effective molecular diagnostics, especially in the field of human healthcare. The gold standard equipment widely employed for detecting specific microorganisms in molecular diagnosis is quantitative real-time polymerase chain reaction (qRT-PCR). However, its limitations in low metagenomic DNA yield samples necessitate exploring alternative approaches. Digital PCR, by quantifying the number of copies of the target sequence, provides absolute quantification results for the bacterial strain. In this study, we compared the diagnostic efficiency of qRT-PCR and digital PCR in detecting a particular bacterial strain (Staphylococcus aureus), focusing on skin-derived DNA samples. Experimentally, specific primer for S. aureus were designed at transcription elongation factor (greA) gene and the target amplicon were cloned and sequenced to validate efficiency of specificity to the greA gene of S. aureus. To quantify the absolute amount of microorganisms present on the skin, the variable region 5 (V5) of the 16S rRNA gene was used, and primers for S. aureus identification were used to relative their amount in the subject's skin. The findings demonstrate the absolute convenience and efficiency of digital PCR in microbial diagnostics. We suggest that the high sensitivity and precise quantification provided by digital PCR could be a promising tool for detecting specific microorganisms, especially in skin-derived DNA samples with low metagenomic DNA yields, and that further research and implementation is needed to improve medical practice and diagnosis.