• Title/Summary/Keyword: Relative precision

Search Result 698, Processing Time 0.024 seconds

Simultaneous Analysis of three Marker Components in Hwangryunhaedok-tang by HPLC-DAD (황련해독탕 중 3종 생리활성 물질의 HPLC-DAD 동시 정량분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • YAKHAK HOEJI
    • /
    • v.55 no.1
    • /
    • pp.64-68
    • /
    • 2011
  • In this study, a high performance liquid chromatography-diode array detector method was established, for simultaneous determination of three compounds, berberine, palmatine and geniposide in Hwangryunhaedok-tang, To develop and validate method, $C_{18}$ column (5 ${\mu}M$, 4.6 mm${\times}$250 mm) was used with gradient mobile phase, water containing 0.1% trifluoroacetic acid (TFA) and MeOH at the column temperature of $30^{\circ}C$. UV wavelength was set at 230 and 280 nm. Validation of the chromatography method was evaluated by linearity, precision and accuracy test. Calibration curve of standard components showed good linearity ($R^2$ > 0.9999). The limits of detection (LOD) and limits of quantification (LOQ) varied from 0.05 to 0.17 ${\mu}g/ml$ and 0.15 to 0.53 ${\mu}g/ml$, respectively. The relative standard deviations (RSDs) data of intra-day and inter-day test were in less than 2.99% and 1.90%, respectively. The results of the accuracy test were in the range of 98.36 to 102.52% with RSDs values 0.32 to 1.98%. The results of validation indicated that this method was a very accurate and sensitive assay.

Simultaneous Determination of Baicalein, Baicalin, Wogonin, and Wogonoside in Rat Plasma by LC-MS/MS for Studying the Pharmacokinetics of the Standardized Extract of Scutellariae Radix

  • Chung, Hye-Jin;Lim, Sun-Young;Kim, In-Sook;Bu, Young-Min;Kim, Ho-Cheol;Kim, Dong-Hyun;Yoo, Hye-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.177-182
    • /
    • 2012
  • A new composition of standardized Scutellariae Radix extract (HPO12) was developed for treatment of Alzheimer's disease. For the preclinical pharmacokinetic study of HPO12, a rapid, sensitive, and selective LCMS/MS method was developed and validated for the simultaneous determination of 4 bioactive compounds, baicalein, baicalin, wogonin, and wogonoside. After extraction with ethylacetate, chromatographic analysis was performed on a Thermo $C_{18}$ column ($150mm{\times}2.1mm$, $3{\mu}m$) with a mobile phase consisting of 0.1% formic acid (A) and 0.1% formic acid in 95% acetonitrile (B) by using gradient elution at a flow rate of $250{\mu}L/min$. Analytes introduced to a mass spectrometer were monitored by multiple reaction monitoring (MRM) in positive ion mode. Using $25{\mu}L$ of plasma sample, the method was validated over the following concentration ranges: 25-5000 ng/mL for baicalein, 20-40000 ng/mL for baicalin, 1-1000 ng/mL for wogonin, and 5-10000 ng/mL for wogonoside. The intra- and inter-day precision and accuracy of the quality control samples at the 4 concentrations showed $\leq$ 13.7% relative standard deviation (RSD) and 86.6-105.5% accuracy. The method was successfully applied to determine the concentrations of baicalein, baicalin, wogonin, and wogonoside in rat plasma after intraperitoneal and oral administrations of HPO12.

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

A Study on the Evaluation Methods of Residual Flux Cleaning Ability by Alternative Semi-Aqueous Cleaners Using Metal Test Tools After Soldering with Solder Paste (솔더페이스트로 솔더링 후 잔류 플럭스 오염물에 대한 준수계 세정제의 금속치구를 이용한 세정성능 평가방법 연구)

  • Lee, Dong-Kee
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.103-109
    • /
    • 2008
  • In this study, in order to develop evaluation method of the cleaning efficiency of residual flux which remains on the surface after soldering with solder paste, a specially designed metal tool is used to reduce spread uncertainty of flux while soldering. Using this tool, the measurement of cleaning efficiency of flux after soldering for some typical alternative semi-aqueous cleaners and 1,1,1-TCE by weighing method was conducted. As the test result of cleaning efficiency for each cleaner at several different cleaning times, the precision of the data is confirmed to within about 4% relative standard deviation (RSD) range. So, it is considered that this would be a good evaluation method for evaluating the cleaning efficiency of the residual flux which remains after solder paste soldering in the alternative cleaning. The results of this test method shows that the cleaning efficiency of ST 100SX and Neozal 750H in the cleaning of residual flux was better than other semi-aqueous cleaners, but its cleaning efficiency was clearly inferior to 1,1,1-TCE.

  • PDF

Simultaneous Determination of Doxifluridine and 5-FU in Liver and Intestine Tissue Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 및 비글견의 간 및 장관 조직에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Jeong, Eun-Ju;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.93-100
    • /
    • 2008
  • A liquid chromatographic method with tandom spectrometric detection (LC/MS/MS) for the simultaneous determination of doxifluridine and its active metabolite, 5-fluorouracil (5-FU) was developed over the concentration range of $5{\sim}2000$ ng/ml, respectively. Doxifluridine, 5-FU and internal standard, 5-chlorouracil (5-CU), were extracted from liver and intestine tissue via protein precipitation. Acetonitrile was used as the extraction solvent and the supernatant was evaporated and reconstructed in mobile phase. Optimum chromatographic separation was achieved on a Agilent Zorbax $C_{18}$ ($100\;mm{\times}2.1\;mm$, $3.5\;{\mu}m$) column with mobile phase run in isocratic with methanol : water (20 : 80, v/v). The flow rate was 0.2 ml/min with total cycle time of 5 min. The lower limit of quantification was validated at 5.0 ng/ml of liver and intestine tissue, for both doxifluridine and 5-FU, respectively. The intra-day and inter-day precision and accuracy of quality control (QC) samples were <11% coefficient of variation and <7% relative error from theoretical concentration for both analytes. In addition, the special designed stability study was performed, because the metabolism of doxifluridine occurs spontaneously even in ice bath for monkey liver. The stability of doxifluridine in liver and intestine of monkey and beagle dog was compared. It was found that bioanalytical validation could not be performed for the monkey liver; however, beagle dog's liver has relatively low speed of metabolism compared to monkey liver and instead of monkey liver, beagle dog's liver could be used for the validation. Bioanalytical validation could be performed in monkey intestine. Eventually, this developed method for liver and intestine will be useful in support of the toxicokinetic and pharmacokinetic studies of doxifluridine and 5-FU.

Coulometric Determination of Plutonium in PWR Spent Fuels (PWR 사용후핵연료내 플루토늄의 전기량적 정량)

  • Sohn, Se Chul;Suh, Moo Yul;Kim, Jung Suk;Song, Byung Chul;Jee, Kwang Yong;Choi,In Kyu;Kim, Won Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.581-586
    • /
    • 2000
  • Separation and coulometric titration method were applied for the determination of plutonium content in samples of PWR spent fuel. Plutonium was separated on an anion exchange(AG MP-1) column and determined by the controlled-potential coulometric titration. In this study, we discussed some experimental conditions related to the separation and determination of plutonium in PWR spent fuel samples. Average accuracy(recovery of plutonium) for the determination of 0.230∼3.02 mg plutonium standard was 99.36%. Average precision(relative standard deviation, RSD) for the determination of 0.250∼0.450 mg plutonium in PWR spent fuel samples was 0.38%.

  • PDF

Studies on the Elution Behavior and the Simultaneous Analysis of Some Metal-Dithiocarbamate Chelates by Reversed-Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇가지 금속-Dithiocarbamate 킬레이트의 용리거동 및 동시분석에 관한 연구)

  • Dai Woon Lee;Yun Je Kim;Hyun Chul Kim;Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.211-226
    • /
    • 1988
  • Liquid chromatographic behavior of several metal ions in dithiocarbamate(DTC) chelates were investigated by reversed phase high performance liquid chromatography on Novapak $C_{18}$ and ${\mu}$-Bondapak $C_{18}$ columns. The optimum conditions for the separation of DTC-metal chelate were examined with respect to the pH, shaking time, flow rate, extraction solvent, and mobile phase strength. The metal ions in mixtures at trace level, chelated with some dithiocarbamate derivatives were separated successfully on Novapak $C_{18}$ column using acetonitrile/methanol/water or acetonitril/water mixtures as mobile phases. It was found that all DTC metal chelates studied were eluted in an acceptable range of capacity factor values ($0{\leqq}log\;k'{\leqq}1$). Although several foreign metal ions were coexisted, high recovery and good precision were attained ; 97.0-106.7 % for the recovery and 0.98-3.41% for the coefficient of variation. Under the optimum analytical conditions, trace metal ions in the composite water samples were determined sucessfully with in relative error of about {\pm}$6.7 %.

  • PDF

LC-MS Determination and Bioavailability Study of Imidapril Hydrochloride after the Oral Administration of Imidapril Tablets in Human Volunteers

  • Yun Ji Hye;Myung Ja Hye;Kim Hye Jin;Lee Sibeum;Park Jong-Sei;Kim Won;Lee Eun-Hee;Moon Cheol Jin;Hwang Sung-Joo
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.463-468
    • /
    • 2005
  • The purpose of the present study was to develop a standard protocol for imidapril hydrochloride bioequivalence testing. For this reason, a specific LC-MS method was developed and validated for the determination of imidapril in human plasma. A solid-phase extraction cartridge, $Sep-pak^{R}$ C18, was used to extract imidapril and ramipril (an internal standard) from deproteinized plasma. The compounds were separated using a XTerra $MS^{R}$?C18 column ($3.5 {\mu}m, 2.1\times150 mm$) and $acetonitrile-0.1\%$ formic acid (67:33, v/v) adjusted to pH 2.4 by 2 mmol/L ammonium formic acid, as mobile phase at 0.3 mL/min. Imidapril was detected as m/z 406 at a retention time of ca. 2.3 min, and ramipril as m/z 417 at ca. 3.6 min. The described method showed acceptable specificity, linearity from 0.5 to 100 ng/mL, precision (expressed as a relative standard deviation of less than $15\%$), accuracy, and stability. The plasma concentration-versus-time curves of eight healthy male volunteers administered a single dose of imidapril (10 mg), gave an $AUC_{12hr}$ of imidapril of $121.48\pm35.81 ng mL^{-1} h$, and $C_{max} and T_{max}$ values of $32.59\pm9.76 ng/mL and 1.75\pm0.27 h$. The developed method should be useful for the determination of imidapril in plasma with sufficient sensitivity and specificity in bioequivalence study.

Simultaneous Separation Analysis of Some Metal Ions in Piperidinedothiocarbamate Chelates by Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇가지 금속 이온들의 Piperidinedithiocarbamate 킬레이트 동시분리분석)

  • Lee, Won;Bahng, Seung-Hoon;Kim, Mi-Kyoung
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Simultaneous separation and analysis of Ni(II), Pd(II), Co(II), Cu(II) and Hg(II) in peperidinedithiocarbamate (PDTC) chelates were investigated by reversed phase liquid chromatography. The optimum conditions for the separation of PDTC metal chelates were examined with respect to the pH, extraction solvent, and mobile phase strength on Novapak $C_{18}$ column using methanol/water mixture as mobile phase. All metal PDTC chelates were eluted in an acceptable range of capacity factor value ($0{\leq}log\;k^{\prime}{\leq}1$). The linear calibration curves were obtained in the concentration range of $0{\sim}1.2{\mu}g/mL$ for five metal ions, and also good precision in the range of 1.96~3.41% RSD was obseved. Under the optimum conditions, trace metat ions in the composite water sample were successfully separated and determined with relative error of ${\pm}2.0%$.

  • PDF

Guidance Filter Design Based on Strapdown Seeker and MEMS Sensors (스트랩다운 탐색기 및 MEMS 센서를 이용한 유도필터 설계)

  • Yun, Joong-Sup;Ryoo, Chang-Kyung;Song, Taek-Lyul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1002-1009
    • /
    • 2009
  • Precision guidance filter design for a tactical missile with a strapdown seeker aided by low-cost strapdown sensors has been addressed in this paper. The low-cost strapdown sensors consist of an IMU with 3-axis accelerometers and gyroscopes, 3-axis magnetometers, and a barometer. Missile's position, velocity, attitude, and bias error of the barometer are considered as state variables. Since the state and measurement equations are highly nonlinear, we adopt UKF(Unscented Kalman Filter). The proposed guidance filter has a function of a navigation filter if target position error is not considered. In the case that the target position error is introduced, the proposed filter can effectively estimate the relative states of the missile to the true target. For specific engagement scenarios, we can observe that observability problems occur.