• 제목/요약/키워드: Relative positions

검색결과 376건 처리시간 0.03초

단일재 알루미늄과 알루미늄/유리섬유 적층재의 결함 위치에 따른 응력분포 및 균열발생 거동 (Stress Distribution and Crack Initiation Behavior due to the Defect Locations in Monolithic Aluminum and Al/Glass Fiber Laminates)

  • 송삼홍;김종성;오동준;윤광준;김철웅
    • 대한기계학회논문집A
    • /
    • 제29권2호
    • /
    • pp.284-292
    • /
    • 2005
  • Material flaws in the from of pre-existing defects can severely affect the crack initiation. Stress distribution and crack initiation life of engineering materials such as monolithic aluminum alloy and Al/Glass fiber laminate may be different according to the defect location. The aim of this study is to evaluate effects of relative location of defects around the circular hole in monolithic aluminum and Al/Glass fiber laminates under cyclic bending moment. Stress distribution and crack initiation behavior near a circular hole are considered. Results of Finite Element (FE) model indicated the features of different stress field due to the relative defects positions. Especially, the defects positions at ${\theta}=0^{\circ}\;and\;{\theta}=30^{\circ}$ was strongly effective in stress concentration factor ($K_t$) and crack initiation behavior.

A NUMERICAL METHOD TO ANALYZE GEOMETRIC FACTORS OF A SPACE PARTICLE DETECTOR RELATIVE TO OMNIDIRECTIONAL PROTON AND ELECTRON FLUXES

  • Pak, Sungmin;Shin, Yuchul;Woo, Ju;Seon, Jongho
    • 천문학회지
    • /
    • 제51권4호
    • /
    • pp.111-117
    • /
    • 2018
  • A numerical method is proposed to calculate the response of detectors measuring particle energies from incident isotropic fluxes of electrons and positive ions. The isotropic flux is generated by injecting particles moving radially inward on a hypothetical, spherical surface encompassing the detectors. A geometric projection of the field-of-view from the detectors onto the spherical surface allows for the identification of initial positions and momenta corresponding to the clear field-of-view of the detectors. The contamination of detector responses by particles penetrating through, or scattering off, the structure is also similarly identified by tracing the initial positions and momenta of the detected particles. The relative contribution from the contaminating particles is calculated using GEANT4 to obtain the geometric factor of the instrument as a function of the energy. This calculation clearly shows that the geometric factor is a strong function of incident particle energies. The current investigation provides a simple and decisive method to analyze the instrument geometric factor, which is a complicated function of contributions from the anticipated field-of-view particles, together with penetrating or scattered particles.

Multi-band imaging of the H2O and SiO masers around the late-type stars using KVN

  • Yun, Youngjoo;Cho, Se-Hyung;Dodson, Richard;Rioja, Maria J.
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.35.2-35.2
    • /
    • 2015
  • We present the results of simultaneous observations of the H2O and SiO masers emitted from the circumstellar envelopes (CSEs) of the late-type stars. These observations have been carried out at the four frequency bands (K, Q, W and D bands) using KVN to apply the source frequency phase referencing (SFPR) analysis to the maser lines. We obtain the relative positions between the H2O and the SiO maser spots by using the SFPR method, which are very important to study the physical links between the inner and the outer parts of the CSEs of the late-type stars. The relative positions between the SiO maser spots of the different transitions are also obtained very accurately, which are very crucial to investigate the pumping mechanism of the SiO maser lines. From our results, the capability of the simultaneous multi-band observation of KVN is proved to be powerful to study the complicated physical environments of the CSEs and the stellar evolution of the late-type stars.

  • PDF

빈도분석에 의한 저수지 유입량 산정 (Estimation of Reservoir Inflow Using Frequency Analysis)

  • 맹승진;황주하;시강
    • 한국농공학회논문집
    • /
    • 제51권3호
    • /
    • pp.53-62
    • /
    • 2009
  • This study was carried out to select optimal probability distribution based on design accumulated monthly mean inflow from the viewpoint of drought by Gamma (GAM), Generalized extreme value (GEV), Generalized logistic (GLO), Generalized normal (GNO), Generalized pareto (GPA), Gumbel (GUM), Normal (NOR), Pearson type 3 (PT3), Wakeby (WAK) and Kappa (KAP) distributions for the observed accumulative monthly mean inflow of Chungjudam. L-moment ratio was calculated using observed accumulative monthly mean inflow. Parameters of 10 probability distributions were estimated by the method of L-moments with the observed accumulated monthly mean inflow. Design accumulated monthly mean inflows obtained by the method of L-moments using different methods for plotting positions formulas in the 10 probability distributions were compared by relative mean error (RME) and relative absolute error (RAE) respectively. It has shown that the design accumulative monthly mean inflow derived by the method of L-moments using Weibull plotting position formula in WAK and KAP distributions were much closer to those of the observed accumulative monthly mean inflow in comparison with those obtained by the method of L-moment with the different formulas for plotting positions in other distributions from the viewpoint of RME and RAE.

Phrase positional effects on F0 peak timing in Tokyo Japanese

  • 조혜선
    • 말소리와 음성과학
    • /
    • 제3권3호
    • /
    • pp.69-75
    • /
    • 2011
  • This paper investigates phrase positional effects on the timing of F0 (pitch) peaks in Tokyo Japanese disyllabic words with varying accent type (HL or LH) and phrase position (final or non final). The F0 peak timing was normalized by the total word duration ('normalized H timing'). The normalized H timing was significantly affected by accent type and phrase position. The H timing was later in the LH accent type than in the HL accent type, and in non final positions than in final positions. In addition, to examine the validity of the quantitative results, different models of phrase position effects were compared by measuring H timing in two approaches: normalization versus relative distance measures. For the normalization measures, the H timing was measured as the time of the F0 peak divided by the total word duration or by the duration of the tone bearing syllable. For the relative distance measures, the H timing was measured as the distance in milliseconds from the end of the word or from the end of the associated syllable. The best model was the normalization by the total word duration, rather than by the duration of the tone bearing syllable. This means that phrase positional effects on the timing of F0 peaks in Japanese disyllabic words are best modeled in terms of proportion of the total word duration.

  • PDF

Gamma 및 Generalized Gamma 분포 모형에 의한 적정 설계홍수량의 유도 (I) -Gamma 분포 모형을 중심으로- (Derivation of Optimal Design Flood by Gamma and Generalized Gamma Distribution Models(I) - On the Gamma Distribution Models -)

  • 이순혁;박명근;정연수;맹승진;류경식
    • 한국농공학회지
    • /
    • 제39권3호
    • /
    • pp.83-95
    • /
    • 1997
  • This study was conducted to derive optimal design floods by Gamma distribution models of the annual maximum series at eight watersheds along Geum , Yeong San and Seom Jin river Systems, Design floods obtained by different methods for evaluation of parameters and for plotting positions in the Gamma distribution models were compared by the relative mean errors and graphical fit along with 95% confidence interval plotted on Gamma probability paper. The results were analyzed and summarized as follows. 1.Adequacy for the analysis of flood flow data used in this study was confirmed by the tests of Independence, Homogeneity and detection of Outliers. 2.Basic statistics and parameters were calculated by Gamma distribution models using Methods of Moments and Maximum Likelihood. 3.It was found that design floods derived by the method of maximum likelihood and Hazen plotting position formular of two parameter Gamma distribution are much closer to those of the observed data in comparison with those obtained by other methods for parameters and for plotting positions from the viewpoint of relative mean errors. 4.Reliability of derived design floods by both maximum likelihood and method of moments with two parameter Gamma distribution was acknowledged within 95% confidence interval.

  • PDF

정상인에서 요천추 코르셋 착용이 엉덩관절을 펼 때 배곧은근과 엉덩관절 폄근의 수축 개시시간에 미치는 영향 (The Effect of a Lumbosacral Corset on the Onset of Rectus Abdominis and Hip Extensor Activity During Hip Extension in Healthy Subjects)

  • 박철홍;권오윤;조상현
    • 한국전문물리치료학회지
    • /
    • 제9권3호
    • /
    • pp.23-37
    • /
    • 2002
  • This study examined the muscle recruitment order during extension of the hip joint in normal subjects, and evaluated whether the external support obtained from wearing a lumbosacral corset had an effect on muscle recruitment leading to increased lumbar stability. The subjects were 40 normal adults (32 male, 8 female) with no history of low back pain and no pathological findings in the nervous or musculoskeletal systems. All subjects extended their hip joints under 3 positions (prone, sidelying, standing). During extension, the onsets of contraction of the rectus abdominis, gluteus maximus, and semitendinosus muscles were measured. Electromyographic activity was measured using a surface electrode, and the muscle contraction onset time was designated as the point exceeding a threshold of 25 ms, using a mean plus twice of the standard deviation. To compare the average order of muscle contraction onset time, a Freedman two-way analysis of variance by ranks was used. The relative difference between muscle contraction onset time wearing and not wearing a lumbosacral corset was measured using a paired t-test. A difference in the average muscle contraction onset order for the rectus abdominis, gluteus maximus, and semitendinosus muscles was observed (p<.05) among three positions. However, wearing a lumbosacral corset did not. change the contraction order. In addition, wearing a lumbosacral corset produced a significant difference (p<.05) in the relative onset time between the rectus abdominis and gluteus maximus in the standing position, but no difference was observed for the other muscles or positions. In the future, patients suffering from low back pain should be compared with normal subjects to determine the effectiveness of a lumbosacral corset in changing muscle recruitment order.

  • PDF

상륙정 입·출거시 안전성을 위한 Well Dock의 형상 및 상대운동 평가 (Well Dock Design and Assessment of Relative Motions During the Operation of the Landing Crafts Within Well Dock)

  • 윤상현;서관희
    • 대한조선학회논문집
    • /
    • 제49권2호
    • /
    • pp.164-173
    • /
    • 2012
  • Landing ship tank with well dock has the important mission transferring troops or landing equipments from sea to shore. Such transfers are usually carried out using landing crafts, which are loaded or unloaded in flooded well dock. In this situation, as relative motions are occur between well dock and landing craft, safety verifications are demanded. In this paper, seakeeping and safety performances are investigated through model test. First of all, well dock dimensions are reviewed and model tests are performed with sea state 3&4 in 180degree wave direction. Model tests are conducted for three relative positions and seakeeping performances are investigated each position.

뮤지컬 전공 남학생에서 후두 높이에 따른 음향학적 측정치에 대한 예비 연구 (A preliminary study of acoustic measures in male musical theater students by laryngeal height)

  • 이광용;이승진
    • 말소리와 음성과학
    • /
    • 제14권2호
    • /
    • pp.55-65
    • /
    • 2022
  • 본 연구에서는 남성 뮤지컬 전공 학생의 발성 시 고, 중, 저의 후두 높이 조건에 따른 음향학적 측정치를 비교하고자 하였다. 또한 휴식 시 후두 융기의 높이를 기준으로 후두의 상대적 높이와 음향학적 측정치 간의 상관관계를 알아보고, 후두의 상대적 높이에 대한 예측 가능성을 확인하고자 하였다. 연구대상은 남성 뮤지컬 가창 전공 남학생 5명이었으며, 고, 중, 저의 후두 위치에서 발성한 /아/ 모음을 각각 10회씩 발성하도록 하여 음향학적 분석을 시행하였다. 발성 시, 휴식 시를 기준으로 고, 중, 저 위치에서의 후두 융기의 상대적 수직 위치를 측정하였다. 연구 결과, 후두의 상대적 위치는 휴식 시를 기준으로 유의한 차이가 있었다. 후두가 하강함에 따라 포먼트 주파수는 감소한 반면, 해당 주파수에서의 스펙트럼 에너지는 증가하였다. 포먼트 주파수는 후두의 상대적 높이와 약함-중간 수준의 정적 상관관계를, 스펙트럼 에너지는 중간 수준의 부적 상관관계를 보였다. 후두의 상대적 높이는 8개의 음향학적 측정치에 의해 예측되었다(수정된 R2=.829). 이를 통하여 비침습적인 방법으로 후두의 상대적 높이를 예측할 수 있는 가능성을 일부 확인하였다.

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.