• 제목/요약/키워드: Relative energy

검색결과 2,021건 처리시간 0.029초

DEA를 활용한 R&D 프로젝트의 효율성 비교 : 산업기술사업을 중심으로 (Comparing Efficiencies of R&D Projects Using DEA : Focused on Industrial Technology Program)

  • 김흥규;강원진;배진희
    • 산업경영시스템학회지
    • /
    • 제38권3호
    • /
    • pp.29-38
    • /
    • 2015
  • In this paper, scale efficiencies and relative efficiencies of R&D projects in Industrial Technology Program, sponsored by Ministry of Trade, Industry and Energy, Korea, are calculated and compared. For the process, various DEA (Data Envelopment Analysis) models are adopted as major techniques. For DEA, two stage input oriented models are utilized for calculating the efficiencies. Next, the calculated efficiencies are grouped according to their subprograms (Industrial Material, IT Fusion, Nano Fusion, Energy Resources, and Resources Technology) and recipient types (Public Enterprise, Large Enterprise, Medium Enterprise, Small Enterprise, Lab., Univ., and etc.) respectively. Then various subprograms and recipient types are compared in terms of scale efficiencies (CCR models) and relative efficiencies (BCC models). In addition, the correlation between the 1st stage relative efficiencies and the 2nd stage relative efficiencies is calculated, from which the causal relationship between them can be inferred. Statistical analysis shows that the amount of input, in general, should increase in order to be scale efficient (CCR models) regardless of the subprograms and recipient types, that the 1st and 2nd stage relative efficiencies are different in terms of the programs and recipient types (BCC models), and that there is no significant correlation between the 1st stage relative efficiencies and the 2nd stage relative efficiencies. However, the results should be used only as reference because the goal each and every subprogram has is different and the situation each and every recipient type faces is different. In addition, the causal link between the 1st stage relative efficiencies and the 2nd relative efficiencies is not considered, which, in turn, is the limitation of this paper.

A Study on Partial Discharge Diagnostic System for Power Cable using RLCR

  • Park, Keeyoung;Choi, Hyungkee;Lee, Chulhee;Hong, Soomi
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.43-47
    • /
    • 2016
  • This system is a diagnosis system that checks whether it causes a partial discharge of a power cable or not. It is to classify normal from abnormal-normal, PD (Partial Discharge) sound through analysis of RLCR (Relative Level Crossing Rate) and spectrogram energy algorithm. Partial discharge diagnostic system has a function that stores PD sound and analyzes the data. The wave shape of PD sound is similar to noise and is systematically generated by partial discharge. Therefore, in this paper, we could discreminate between normal and abnormal case using relative level crossing rate (RLCR) and spectrogram of frequency energy rate.

Effect of Improving Accuracy for Effective Atomic number (EAN) and Relative Electron Density (RED) extracted with Polynomial-based Calibration in Dual-energy CT

  • Daehong Kim;Il-Hoon Cho;Mi-jo Lee
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1017-1023
    • /
    • 2023
  • The purpose of this study was to improve the accuracy of effective atomic number (EAN) and relative electron density (RED) using a polynomial-based calibration method using dual-energy CT images. A phantom composed of 11 tissue-equivalent materials was acquired with dual-energy CT to obtain low- and high-energy images. Using the acquired dual-energy images, the ratio of attenuation of low- and high-energy images for EAN was calibrated based on Stoichiometric, Quadratic, Cubic, Quartic polynomials. EAN and RED were extracted using each calibration method. As a result of the experiment, the average error of EAN using Cubic polynomial-based calibration was minimum. Even in the RED image extracted using EAN, the error of the Cubic polynomial-based RED was minimum. Cubic polynomial-based calibration contributes to improving the accuracy of EAN and RED, and would like to contribute to accurate diagnosis of lesions in CT examinations or quantification of various materials in the human body.

Molecular Dynamics Free Energy Simulation Study to Rationalize the Relative Activities of PPAR δ Agonists

  • Lee, Woo-Jin;Park, Hwang-Seo;Lee, Sangyoub
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권2호
    • /
    • pp.363-371
    • /
    • 2008
  • As a computational method for the discovery of the effective agonists for PPARd, we address the usefulness of molecular dynamics free energy (MDFE) simulation with explicit solvent in terms of the accuracy and the computing cost. For this purpose, we establish an efficient computational protocol of thermodynamic integration (TI) that is superior to free energy perturbation (FEP) method in parallel computing environment. Using this protocol, the relative binding affinities of GW501516 and its derivatives for PPARd are calculated. The accuracy of our protocol was evaluated in two steps. First, we devise a thermodynamic cycle to calculate the absolute and relative hydration free energies of test molecules. This allows a self-consistent check for the accuracy of the calculation protocol. Second, the calculated relative binding affinities of the selected ligands are compared with experimental IC50 values. The average deviation of the calculated binding free energies from the experimental results amounts at the most to 1 kcal/mol. The computational efficiency of current protocol is also assessed by comparing its execution times with those of the sequential version of the TI protocol. The results show that the calculation can be accelerated by 4 times when compared to the sequential run. Based on the calculations with the parallel computational protocol, a new potential agonist of GW501516 derivative is proposed.

Thermodynamics of Small Electron-Bound Water Clusters

  • Lee, Sik;Lee, Han-Myoung
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권6호
    • /
    • pp.802-804
    • /
    • 2003
  • The relative stabilities of weak binding clusters are sensitive to temperature due to the entropy effect. Thus, here we report significant changes in relative stabilities between two low-energy electron-water trimer structures and those between three low-energy electron-water pentamer structures, as the temperature increases. The trimer and pentamer show structural changes around 200 K.

Energy-based design base shear for RC frames considering global failure mechanism and reduced hysteretic behavior

  • Merter, Onur;Ucar, Taner
    • Structural Engineering and Mechanics
    • /
    • 제63권1호
    • /
    • pp.23-35
    • /
    • 2017
  • A nonlinear static procedure considering work-energy principle and global failure mechanism to estimate base shears of reinforced concrete (RC) frame-type structures is presented. The relative energy equation comprising of elastic vibrational energy, plastic strain energy and seismic input energy is obtained. The input energy is modified with a factor depending on damping ratio and ductility, and the energy that contributes to damage is obtained. The plastic energy is decreased with a factor to consider the reduced hysteretic behavior of RC members. Given the pre-selected failure mechanism, the modified energy balance equality is written using various approximations for modification factors of input energy and plastic energy in scientific literature. External work done by the design lateral forces distributed to story levels in accordance with Turkish Seismic Design Code is calculated considering the target plastic drift. Equating the plastic energy obtained from energy balance to external work done by the equivalent inertia forces considering, a total of 16 energy-based base shears for each frame are derived considering different combinations of modification factors. Ductility related parameters of modification factors are determined from pushover analysis. Relative input energy of multi degree of freedom (MDOF) system is approximated by using the modal-energy-decomposition approach. Energy-based design base shears are compared with those obtained from nonlinear time history (NLTH) analysis using recorded accelerograms. It is found that some of the energy-based base shears are in reasonable agreement with the mean base shear obtained from NLTH analysis.

플라이휠 에너지 저장장치 자기부상 안정성 시뮬레이션 및 실험분석 (Simulation and Experimental Analysis of Magnetic Levitation Relative Stability for the Flywheel Energy Storage)

  • 박병철;정세용;한상철;이정필;한영희;박병준
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1605-1610
    • /
    • 2010
  • In this paper, the relative stability of magnetic bearing system for the flywheel energy storage is evaluated using both simulation and experimental analysis. We make the simulation model for the magnetic bearing flywheel system using the rigid body shaft model. According to international standard ISO 14839-3, We experimentally analyzed the relative stability of magnetic bearing system. Additionally using both the simulation model and experimental tests, Phase margin and Gain margin is acquired through Nyquist plot.

QFPR Analysis for Selectivity of between Na+ and Li+ Ions to 12-Crown-4: by a Monte Carlo Simulation Study

  • Kim, Hag-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권10호
    • /
    • pp.2823-2829
    • /
    • 2010
  • We investigated the solvent effects on the relative free energies of binding of $Na^+$ and $Li^+$ ions to 12-crown-4 and ${\Delta}log\;K_s$ (the difference of stability constant of binding) by a Monte Carlo simulation of statistical perturbation theory (SPT) in several solvents. Comparing the relative free energies of binding of $Na^+$ and $Li^+$ ions to 12-crown-4, in $CH_3OH$ of this study with experimental works, there is a good agreement among the studies. We have reported the quantitative free energy polarity (of solvent) relationships (QFPR) of the relationship between the relative free energies and solvent polarity studied on the solvent effects on the relative free energies of binding of $Na^+$ and $Li^+$ ions to 12-crown-4.

Solvent Effect on Relative Gibbs Free Energy and Structural Property of $Eu^{3+}\;to\;Yb^{3+}$ Ion Mutation: A Monte Carlo Simulation Study

  • 김학성
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.877-882
    • /
    • 2001
  • The solvent effects on the relative free energies of Eu3+ to Yb3+ ion mutation in solution have been investigated using a Monte Carlo simulation of statistical perturbation theory (SPT). Our results agree well with available data that were obtained by others. Particularly, the results of water (SPC/E) solvent are almost identical with experimental data. For the present Eu3+ and Yb3+ ions, the relative free energies of solvation vs. Born’s function of bulk solvents decrease with increasing Born’s function of bulk solvents. There is also good agreement between the calculated structural properties in this study and the published works obtained by computer simulation and experimental work.

개방회로 상태 PEMFC 내부 온도와 습도 측정을 통한 수분투과 분석 (Analysis of Water Transport through Measurement of Temperature and Relative Humidity in PEMFC at OCV)

  • 김태형;한재수;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.353-362
    • /
    • 2022
  • In this study, water diffusion in proton exchange membrane fuel cell at open circuit voltage (OCV) was analyzed through experiment. First, the reliability of the micro-sensor (SHT31) was verified. It was concluded the micro-sensor has an excellent reliability at 60℃ and 70℃. After the sensor reliability test, the temperature and relative humidity measurement in bipolar-plate was conducted at OCV. To analyze water distribution and water flux, the temperature and relative humidity was converted into dew point. To the end, it was found water concentration affects water diffusion.