• Title/Summary/Keyword: Relative depth

Search Result 880, Processing Time 0.031 seconds

Stereoscopic Millimeter-wave Image Processing for Depth Information

  • Park, Min-Chul;Son, Jung-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1022-1024
    • /
    • 2009
  • Stereoscopic Images provide depth information with the relative distances between the objects in the images. There are many different ways to extract disparity maps from the visible spectral images. For the infrared spectral range, the same approach cannot be utilized for the innate low resolution and colorless features because typical methods require corresponding features between the images. The authors suggest a new approach that makes use of image segmentation to obtain depth information for stereoscopic millimeter-wave images. For image segmentation a selective visual attention model based on the theory of a feature-integration of attention is used. Experimental results show the proposed method provides reasonable depth information for object shape recognition and display.

  • PDF

Non-destructive assessment of carbonation in concrete using the ultrasonic test: Influenced parameters

  • Javad Royaei;Fatemeh Nouban;Kabir Sadeghi
    • Structural Engineering and Mechanics
    • /
    • v.89 no.3
    • /
    • pp.301-308
    • /
    • 2024
  • Concrete carbonation is a continuous and slow process from the outside to the inside, in which its penetration slows down with the increased depth of carbonation. In this paper, the results of the evaluation of the measurement of concrete carbonation depth using a non-destructive ultrasonic testing method are presented. According to the results, the relative nonlinear parameter caused more sensitivity in carbonation changes compared to Rayleigh's fuzzy velocity. Thus, the acoustic nonlinear parameter is expected to be applied as a quantitative index to recognize carbonation effects. In this research, combo diagrams were developed based on the results of ultrasonic testing and the experiment to determine carbonation depth using a phenolphthalein solution, which could be considered as instructions in the projects involving non-destructive ultrasonic test methods. The minimum and maximum accuracy of this method were 89% and 97%, respectively, which is a reasonable range for operational projects. From the analysis performed, some useful expressions are found by applying the regression analysis for the nonlinearity index and the carbonation penetration depth values as a guideline.

Bathymetric mapping in Dong-Sha Atoll using SPOT data

  • Huang, Shih-Jen;Wen, Yao-Chung
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.525-528
    • /
    • 2006
  • The remote sensing data can be used to calculate the water depth especially in the clear and shallow water area. In this study, the SPOT data was used for bathymetric mapping in Dong-Sha atoll, located in northern South China Sea. The in situ sea depth was collected by echo sounder as well. A global positioning system was employed to locate the accurate sampling points for sea depth. An empirical model between measurement sea depth and band digital count was determined and based on least squares regression analysis. Both non-classification and unsupervised classification were used in this study. The results show that the standard error is less than 0.9m for non-classification. Besides, the 10% error related to the measurement water depth can be satisfied for more than 85% in situ data points. Otherwise, the 10% relative error can reach more than 97%, 69%, and 51% data points at class 4, 5, and 6 respectively if supervised classification is applied. Meanwhile, we also find that the unsupervised classification can get more accuracy to estimate water depth with standard error less than 0.63, 0.93, and 0.68m at class 4, 5, and 6 respectively.

  • PDF

Decision of Interface and Depth Scale Calibration of Multilayer Films by SIMS Depth Profiling

  • Hwang, Hye-Hyun;Jang, Jong-Shik;Kang, Hee-Jae;Kim, Kyung-Joong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.274-274
    • /
    • 2012
  • In-depth analysis by secondary ion mass spectrometry (SIMS) is very important for the development of electronic devices using multilayered structures, because the quantity and depth distribution of some elements are critical for the electronic properties. Correct determination of the interface locations is critical for the calibration of the depth scale in SIMS depth profiling analysis of multilayer films. However, the interface locations are distorted from real ones by the several effects due to sputtering with energetic ions. In this study, the determination of interface locations in SIMS depth profiling of multilayer films was investigated by Si/Ge and Ti/Si multilayer systems. The original SIMS depth profiles were converted into compositional depth profiles by the relative sensitivity factors (RSF) derived from the atomic compositions of Si-Ge and Si-Ti alloy reference films determined by Rutherford backscattering spectroscopy. The thicknesses of the Si/Ge and Ti/Si multilayer films measured by SIMS depth profiling with various impact energy ion beam were compared with those measured by TEM. There are two methods to determine the interface locations. The one is the feasibility of 50 atomic % definition in SIMS composition depth profiling. And another one is using a distribution of SiGe and SiTi dimer ions. This study showed that the layer thicknesses measured with low energy oxygen and Cs ion beam and, by extension, with method of 50 atomic % definition were well correlated with the real thicknesses determined by TEM.

  • PDF

The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.

Stereoscopic Effect of 3D images according to the Quality of the Depth Map and the Change in the Depth of a Subject (깊이맵의 상세도와 주피사체의 깊이 변화에 따른 3D 이미지의 입체효과)

  • Lee, Won-Jae;Choi, Yoo-Joo;Lee, Ju-Hwan
    • Science of Emotion and Sensibility
    • /
    • v.16 no.1
    • /
    • pp.29-42
    • /
    • 2013
  • In this paper, we analyze the effect of the depth perception, volume perception and visual discomfort according to the change of the quality of the depth image and the depth of the major object. For the analysis, a 2D image was converted to eighteen 3D images using depth images generated based on the different depth position of a major object and background, which were represented in three detail levels. The subjective test was carried out using eighteen 3D images so that the degrees of the depth perception, volume perception and visual discomfort recognized by the subjects were investigated according to the change in the depth position of the major object and the quality of depth map. The absolute depth position of a major object and the relative depth difference between background and the major object were adjusted in three levels, respectively. The details of the depth map was also represented in three levels. Experimental results showed that the quality of the depth image differently affected the depth perception, volume perception and visual discomfort according to the absolute and relative depth position of the major object. In the case of the cardboard depth image, it severely damaged the volume perception regardless of the depth position of the major object. Especially, the depth perception was also more severely deteriorated by the cardboard depth image as the major object was located inside the screen than outside the screen. Furthermore, the subjects did not felt the difference of the depth perception, volume perception and visual comport from the 3D images generated by the detail depth map and by the rough depth map. As a result, it was analyzed that the excessively detail depth map was not necessary for enhancement of the stereoscopic perception in the 2D-to-3D conversion.

  • PDF

Performance Analysis of Landing Point Designation Technique Based on Relative Distance to Hazard for Lunar Lander (달 착륙선의 위험 상대거리 기반 착륙지 선정기법 성능 분석)

  • Lee, Choong-Min;Park, Young-Bum;Park, Chan-Gook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.12-22
    • /
    • 2016
  • Lidar-based hazard avoidance landing system for lunar lander calculates hazard cost with respect to the desired local landing area in order to identify hazard and designate safe landing point where the cost is minimum basically using slope and roughness of the landing area. In this case, if the parameters are only considered, chosen landing target can be designated near hazard threatening the lander. In order to solve this problem and select optimal safe landing point, hazard cost based on relative distance to hazard should not be considered as well as cost based on terrain parameters. In this paper, the effect of hazard cost based on relative distance to hazard on safe landing performance was analyzed and it was confirmed that landing site designation with two relative distances to hazard results in the best safe landing performance by an experiment using three-dimensional depth camera.

Feasibility Study of a Verification Tool for the Treatment of Cervical Intraepithelial Neoplasia Using Relative Electrical Property Change Before and After Laser Irradiation (레이저 조사 전후 자궁경부조직의 상대적 전기물성 스펙트럼 변화를 이용한 자궁경부 이형성증 치료검증도구의 가능성 평가)

  • Jun Beom, Heo;Tingting, Zhang;Tong In, Oh;Dong Choon, Park
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.409-416
    • /
    • 2022
  • Since the detection of cervical intraepithelial neoplasia (CIN) is increasing due to regular cervical cancer screening, there is a high demand for simpler tools to diagnose and treat CIN in the clinic. In this study, we proposed an electric property of cervical tissue to verify treatment using a laser. At first, we observed the depth and width of ablated cervical tissues for 29 samples according to four different pulse energy of the fractional CO2 laser to find enough pulse energy to reach the basement layer for initiated CIN. And then, the relative frequency differences in impedance spectrum before and after laser irradiation for ten non-CIN samples were collected using bioimpedance spectroscopy with a multi-electrode probe. As a result, the laser ablated the cervical tissues with a depth of more than 300 ㎛ at 100 mJ pulse energy. Also, we confirmed that the relative changes of electrical property for cervical tissue increased as the pulse energy of laser output increased, and the variation between samples decreased. Since the relative change in electrical properties of cervical tissue can be easily and quickly measured, the proposed technique paves the way for further verification and follow-up study of laser treatment for CIN.

A Study on the Effect of Delta-V Based on Vehicle Damages and Injuries Subjected by Rear-End Collisions (후미추돌사고의 유효충돌속도가 차량손상 및 승차자 상해에 미치는 영향에 관한 연구)

  • Kang, Sung-Mo;Ahn, Byung-Joon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.72-80
    • /
    • 2008
  • In a case of an automobile collision, vehicle damage and injury of the driver and the passenger occur. The scale of the collision which is effected by the extent of vehicle damage and the injury of the passenger, depends on the delta-V. Based on the photograph interpretation o the actual case of accidents in the Seoul and the Incheon area, this study measured the depth of crush and calculated the delta-V. Through verifying the correlation of the depth of crush and the change of velocity, relative equation was evaluated and compared with the prior study results to prove that they are almost identical. Thus, the depth of crush can be used as an index of the degree of impact, which can be utilized as the change of velocity to evaluate the level of injury done to the passengers. However, the period of hospitalization and diagnostics claimed by the injured proves to have no correlation with the delta-V and the extent of vehicle damage, this is due to the non-objective way of diagnosis and the anamnesis of the injured. This study established the absolute limit harmlessness and the choosing limit harmlessness, allowing the appraisal for Yes or No of the injury or the harmlessness based on the prior studies. Moreover, utilizing the relative equation formed between the depth of crush and the delta-V, each case of collision was compared and evaluated in comparison to the limit harmlessness to prove that the 90.4% of the so-called 'claiming-to-be-injured' were exaggerating or fabricating.

Mono-Vision Based Satellite Relative Navigation Using Active Contour Method (능동 윤곽 기법을 적용한 단일 영상 기반 인공위성 상대항법)

  • Kim, Sang-Hyeon;Choi, Han-Lim;Shim, Hyunchul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.902-909
    • /
    • 2015
  • In this paper, monovision based relative navigation for a satellite proximity operation is studied. The chaser satellite only uses one camera sensor to observe the target satellite and conducts image tracking to obtain the target pose information. However, by using only mono-vision, it is hard to get the depth information which is related to the relative distance to the target. In order to resolve the well-known difficulty in computing the depth information with the use of a single camera, the active contour method is adopted for the image tracking process. The active contour method provides the size of target image, which can be utilized to indirectly calculate the relative distance between the chaser and the target. 3D virtual reality is used in order to model the space environment where two satellites make relative motion and produce the virtual camera images. The unscented Kalman filter is used for the chaser satellite to estimate the relative position of the target in the process of glideslope approaching. Closed-loop simulations are conducted to analyze the performance of the relative navigation with the active contour method.