• Title/Summary/Keyword: Relative contrast ratio

Search Result 75, Processing Time 0.024 seconds

Retrospective Evaluation of Discrepancies between Radiological and Pathological Size of Hepatocellular Carcinoma Masses

  • Tian, Fei;Wu, Jian-Xiong;Rong, Wei-Qi;Wang, Li-Ming;Wu, Fan;Yu, Wei-Bo;An, Song-Lin;Liu, Fa-Qiang;Feng, Li;Liu, Yun-He
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9487-9494
    • /
    • 2014
  • Background: The size of a hepatic neoplasm is critical for staging, prognosis and selection of appropriate treatment. Our study aimed to compare the radiological size of solid hepatocellular carcinoma (HCC) masses on magnetic resonance imaging (MRI) with the pathological size in a Chinese population, and to elucidate discrepancies. Materials and Methods: A total of 178 consecutive patients diagnosed with HCC who underwent curative hepatic resection after enhanced MRI between July 2010 and October 2013 were retrospectively identified and analyzed. Pathological data of the whole removed tumors wereassessed and differences between radiological and pathological tumor size were identified. All patients were restaged using a modified Tumor-Node-Metastasis (TNM) staging system postoperatively according to the maximum diameter alteration. The lesions were classified as hypo-staged, iso-staged or hyper-staged for qualitative assessment. In the quantitative analysis, the relative pre and postoperative tumor size contrast ratio ($%{\Delta}size$) was also computed according to size intervals. In addition, the relationship between radiological and pathological tumor diameter variation and histologic grade was analyzed. Results: Pathological examination showed 85 (47.8%) patients were overestimated, 82 (46.1%) patients underestimated, while accurate measurement by MRI was found in 11 (6.2%) patients. Among the total subjects, 14 (7.9%) patients were hypo-staged and 15 (8.4%) were hyper-staged post-operatively. Accuracy of MRI for calculation and characterized staging was related to the lesion size, ranging from 83.1% to 87.4% (<2cm to ${\geq}5cm$, p=0.328) and from 62.5% to 89.1% (cT1 to cT4, p=0.006), respectively. Overall, MRI misjudged pathological size by 6.0 mm (p=0.588 ), and the greatest difference was observed in tumors <2cm (3.6 mm, $%{\Delta}size=16.9%$, p=0.028). No statistically significant difference was observed for moderately differentiated HCC (5.5mm, p=0.781). However, for well differentiated and poorly differentiated cases, radiographic tumor maximum diameter was significantly larger than the pathological maximum diameter by 3.15 mm and underestimated by 4.51 mm, respectively (p=0.034 and 0.020). Conclusions: A preoperative HCC tumor size measurement using MRI can provide relatively acceptable accuracy but may give rise to discrepancy in tumors in a certain size range or histologic grade. In pathological well differentiated subjects, the pathological tumor size was significantly overestimated, but underestimated in poorly differentiated HCC. The difference between radiological and pathological tumor size was greatest for tumors <2 cm. For some HCC patients, the size difference may have implications for the decision of resection, transplantation, ablation, or arterially directed therapy, and should be considered in staging or selecting the appropriate treatment tactics.

Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breath-hold Imaging Sequences (간의 3T 자기공명영상에서 초상자성산화철 조영증강 급속호흡정지영상기법들간의 양적 및 질적 비교평가)

  • Cho, Kyung-Eun;Yu, Jeong-Sik;Chung, Jae-Joon;Kim, Joo-Hee;Kim, Ki-Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.31-40
    • /
    • 2010
  • Purpose : To compare the relative values of various fast breath-hold imaging sequences for superparamagnetic iron-oxide (SPIO)-enhanced hepatic MRI for the assessment of solid focal lesions with a 3T MRI unit. Materials and Methods : 102 consecutive patients with one or more solid malignant hepatic lesions were evaluated by spoiled gradient echo (GRE) sequences with three different echo times (2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10]) for $T2^*$-weighted imaging in addition to T2-weighted turbo spin echo (TSE) sequence following intravenous SPIO injection. Image qualities of the hepatic contour, vascular landmarks and artifacts were rated by two independent readers using a four-point scale. For quantitative analysis, contrast-to-noise ratio (CNR) was measured in 170 solid focal lesions larger than 1 cm (107 hepatocellular carcinomas, nine cholangiocarcinomas and 54 metastases). Results : GRE_5.8 showed the highest mean points for hepatic contour, vascular anatomy and imaging artifact presence among all of the subjected sequences (p<0.001) and was comparable (p=0.414) with GRE_10 with regard to lesion conspicuity. The mean CNRs were significantly higher (p<0.001) in the following order: GRE_10 ($24.4{\pm}14.5$), GRE_5.8 ($14.8{\pm}9.4$), TSE ($9.7{\pm}6.3$), and GRE_2.4 ($7.9{\pm}6.4$). The mean CNRs of CCCs and metastases were higher than those of HCCs for all imaging sequences (p<0.05). Conclusion : Regarding overall performances, GRE using a moderate echo time of 5.8 msec can provide the most reliable data among the various fast breath-hold SPIO-enhanced hepatic MRI sequences at 3T unit despite the lower CNR of GRE_5.8 compared to that of GRE_10.

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

Evaluation for Rock Cleavage Using Distribution of Microcrack Spacings (III) (미세균열의 간격 분포를 이용한 결의 평가 (III))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.311-324
    • /
    • 2016
  • The characteristics of the rock cleavage in Jurassic granite from Geochang were analysed. The evaluation for three quarrying planes and three rock cleavages was performed using the parameters such as (1) reduction ratio between the value of spacing and the value of length, (2) microcrack spacing frequency(N), (3) total spacing($1mm{\geq}$), (4) exponential constant(a), (5) magnitude of exponent(${\lambda}$), (6) mean spacing($S_{mean}$), (7) difference value($S_{mean}-S_{median}$) between mean spacing and median spacing($S_{median}$) and (8) density of spacing. Especially the close dependence between the above spacing parameters and the parameters from the spacing-cumulative frequency diagrams was derived. The discrimination factors representing three quarrying planes and three rock cleavages were acquired through these mutual contrast. The analysis results of the research are summarized as follows. First, the reduction ratios of frequency(N), mean value, median value, the above difference value($S_{mean}-S_{median}$) and density for three rock cleavages are in orders of G(grain, (G1 + G2)/2) < H(hardway, (H1 + H2)/2) < R(rift, (R1 + R2)/2), H < G $\ll$ R, H < G $\ll$ R, H < G < R and H < G $\ll$ R. The values of the above five parameters for three planes show the various orders of R'(rift plane) $\ll$ H'(hardway plane) < G'(grain plane), R' $\ll$ G' < H', R' < H' < G', R' < G' < H' and R' $\ll$ H' < G', respectively. Second, the values of (I) parameters(2, 3, 4 and 5) and (II) parameters(6, 7 and 8) are in orders of (I) H < G < R and (II) R < G < H. On the contrary, the values of the above two groups(I~II) of parameters for three planes show reverse orders. Third, to review the overall characteristics of the arrangement among the six diagrams, these diagrams show an order of R2 < R1 < G2 < G1 < H2 < H1 from the related chart. In other words, above six diagrams can be summarized in order of rift(R1 + R2) < grain(G1 + G2) < hardway(H1 + H2). These results indicate a relative magnitude of rock cleavage related to microcrack spacing. Especially, two parameters for each diagram, the above difference value($S_{mean}-S_{median}$) and mean spacing, could provide advanced information for prediction the order of arrangement among the diagrams. Finally, the general chart for three planes and three rock cleavages were made. From the related chart, three exponential straight lines for three rock cleavages show an order of R(R1 + R2) < G(G1 + G2) < H(H1 + H2). On the contrary, three lines for three planes show an order of H'(R2 + G2) < G'(R1 + H2) < R'(G1 + H1). Consequently, correlation of the mutually reverse order between three planes and three rock cleavages can be drawn from the related chart.

Feed Value of the Different Plant Parts of Main Forage Rice Varieties (사료용 벼 주요 품종의 수확부위 별 사료가치)

  • Ahn, Eok-Keun;Won, Yong-Jae;Kang, Kyung-Ho;Park, Hyang-Mi;Jung, Kuk-Hyun;Hyun, Ung-Jo;Lee, Yoon-Sung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In order to manufacture feed suitable for consumer use and provide feed value information, we analyzed the feed components of the four main forage rice varieties by plant parts harvested 30 days after heading. The contents of the six feed ingredients were significantly different (p<0.05) among harvested parts. In the panicle, the crude protein (CP) (6.97%) and lignin (3.11%) were the highest, while the crude ash (CA) and neutral detergent fiber (NDF) contents were significantly lower, resulting in a total digestible nutrient (TDN) content of 77.29%, which is higher than that of the stem (64.82%) and leaf blade and sheath (LBS) (63.57%) (p<0.05). In contrast, the content of crude fat (CF) did not differ significantly among parts (p<0.05). In panicles from 'Jonong', 'Nokyang' and 'Yeongwoo', the TDN content of each cultivar was 78.48-79.07%, with no significant difference among the varieties. In 'Mogwoo' (Mw), the CP content was 8.70%, which was much higher than that of other varieties (p<0.05). In particular, the Mw TDN content was slightly lower in the panicle (72.95%) but higher in the stem (75.37%) and LBS (66.49%) than in the other varieties. The CA, NDF, acid detergent fiber (ADF), and lignin contents were also very low compared to other varieties; therefore, the feed value of the stem and LBS was excellent. In addition, the total dry matter weight (DMW) was 123 g per hill, which was much higher than 82-105 g per hill for other varieties. The distribution of DMW by part was LBS (56.9 g), stem (36.8 g), and panicle (29.3 g), and because the parts, except the panicles, were much higher than the 43-57% of other varieties (grain straw ratio: 76%), rice straw is advantageous in terms of quantity and feed value when used as forage on farms. The relative feed value (RFV) of the four cultivars ranged from 86.79-403.74 across all parts, and hay of grade 3 or higher with an RFV of 100 or more increased with delayed heading in both stems and LBS. This is due to the accumulation of starch into grains during ripening, which supports the observation that the RFV of the early flowering 'Jonong' and 'Nokyang' panicles increased.