• Title/Summary/Keyword: Relative Thermal Control

Search Result 90, Processing Time 0.03 seconds

Effect of Canopy Covering on Thermal Insulation and Freezing Tolerence of 'Shiranui' Hybrid Mandarin Cultivated in Field During Winter Season (수관 피복이 노지재배 '부지화' 감귤나무의 보온과 내한성에 미치는 영향)

  • Joa, Jae-Ho;Kang, Seok-Beom;Moon, Young-Eel;Lee, Hae-Jin
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.441-447
    • /
    • 2021
  • It were investigated changes in internal and external temperature, relative humidity using tyvek, weedstop, and 35% shading net as covering material to reduce the freezing damage of 'Shiranui' hybrid mandarin grown in open field. It were also evaluated canopy covering effect and LT50 of leaves by covering material when it was cold at -2℃. In tyvek, temperature difference between inside and outside was low at the height of 1.5m and was high at 0.4m. The relative humidity differed greatly between day and night, and was high at 6-8 a.m. At -2℃, Sum of temperature at the height of 1.5m of canopy for 24-hour after covering were at 3.4℃ higher in tyvek than in control. The LT50 of leaves was at 1.51℃ in tyvek, 1.33℃ in withstop, and 1.61℃ in 35% shading net lower than in control. Considering thermal insulation and relative humidity in canopy, tyvek is expected to reduce low temperature damage when covering after making a fine hole for ventilation.

Analysis of Thermal Performance of Ardisia Species Used for Improvement of Indoor Environment (실내환경 개선을 위한 Ardisia속 식물의 열 성능 평가)

  • Lee, Na Young;Han, Seung Won;Joo, Na Ri;Lee, Jong Suk
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • This study investigated the changes of indoor thermal environment by Ardisia species planted in indoor space. Three Ardisia species (Ardisia japonica, Ardisia crenata and Ardisia pusilla) were used in this study and differences of temperature and relative humidity were ascertained in an empty chamber with and without plants. In high temperatures over $24^{\circ}C$, Ardisia species cooled down chamber more as compared to the control without plants, but there were no significant differences among Ardisia species. Ardisia crenata showed high relative humidity of $57.3{\pm}3.1%$ during most of the day time and $60.8{\pm}2.5%$ at low temperatures. However, Ardisia japonica and Ardisia pusilla showed $54.7{\pm}1.18%$ and $52.5{\pm}2.4%$, respectively, on the average, and they maintained comfortable relative humidity during most of the day time. When the setting temperature was decreased from 28 to $26^{\circ}C$, Ardisia species showed 7.5~13.6 times greater cooling efficiency as compared to the control without plants, and at low temperatures the chamber without plants showed higher themal energy than the chamber with plants. Ardisia species were effective on cooling down the temperature at high temperatures and they showed a tendency to maintain proper temperatures at low temperatures.

Effect of in ovo feeding of γ-aminobutyric acid combined with embryonic thermal manipulation on hatchability, growth, and hepatic gene expression in broilers

  • Chris Major, Ncho;Akshat, Goel;Vaishali, Gupta;Chae-Mi, Jeong;Yang-Ho, Choi
    • Animal Bioscience
    • /
    • v.36 no.2
    • /
    • pp.284-294
    • /
    • 2023
  • Objective: This study investigated the effects of in ovo feeding of γ-aminobutyric acid (GABA) and embryonic thermal manipulation (ETM) on growth performance, organ indices, plasma biochemical parameters, hepatic antioxidant levels, and expression of lipid metabolism-related genes in broilers. Methods: Two hundred and fifty eggs were assigned to one of four treatments: control eggs incubated under standard conditions (CON); eggs that received an in ovo injection of 10% GABA on day 17.5 of incubation (G10); thermally manipulated eggs between days 10 and 18 of incubation at 39.6°C for 6 h daily (TM); and eggs that received both treatments during incubation (G10+TM). After 28 days of rearing, five birds per treatment were selected for blood and organ sampling. Results: No differences were found in hatchability or growth parameters among different treatment groups. Hepatic gene expression of catalase (CAT) and glutathione peroxidase 1 (GPx1) was upregulated (p = 0.046 and p = 0.006, respectively) in the G10+TM group, while that of nuclear factor erythroid 2-related factor 2 (NRF2) was upregulated (p = 0.039) in the G10 group. In addition, the relative gene expression of NADPH oxidase 1 (NOX1) was significantly lower (p = 0.007) in all treatment groups than that in the CON group. Hepatic fatty acid synthase (FAS) levels and average daily feed intake (ADFI) of last week showed a positive correlation (r = 0.50, p = 0.038). In contrast, the relative gene expression of the extracellular fatty acid-binding protein (EXFAB) and peroxisome proliferator-activated receptor-γ (PPAR-γ) were positively correlated (r = 0.48, p = 0.042 and r = 0.50, p = 0.031) with the overall ADFI of birds. Conclusion: Taken together, the results of this study suggest that the combination of in ovo feeding of GABA and ETM can enhance hepatic antioxidant function in broilers.

Effect of Vanes on Flow Distribution in a Diffuser Type Recuperator Header (디퓨저 타입 레큐퍼레이터 헤더에서 유동분배에 미치는 베인의 영향)

  • Jeong Young-Jun;Kim Seo-Young;Kim Kwang-Ho;Kwak Jae-Su;Kang Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.819-825
    • /
    • 2006
  • In a SOFC/GT (solid oxide fuel cell/gas turbine) hybrid power generation system, the recuperator is an indispensible component to enhance system performance. Since the expansion ratio to the recuperator core is very large, generally, the effective header design to distribute the flow uniformly before entering the core is crucial to guarantee the required performance. In the present study, we focus on the design of a diffuser type recuperator header with a 90 degree turn inlet port. To reduce the flow separation and recirculation flows, multiple horizontal vanes are used. The number of horizontal vanes is varied from 0 to 24. The air flow velocity is measured at 40 points just behind the core outlet by using a hot wire anemometer. Then, the flow non-uniformity is evaluated from the measured flow velocity. The experimental results showed that inlet air velocity did not effect on relative flow non-uniformity. According to increasing the number of horizontal vanes, flow non-uniformity reduced about $40{\sim}50%$ than without using horizontal vanes.

Development of Fuel Cell/Battery Hybrid Vehicle (연료전지/배터리 하이브리드 차량 개발)

  • Son Yeong Jun;Park Gu Gon;Im Seong Dae;Eom Seok Gi;Yang Tae Hyeon;Yun Yeong Gi;Lee Won Yong;Kim Chang Su
    • 한국전기화학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.103-110
    • /
    • 2005
  • Fuel cell systems are consisted of various parts, for example fuel cell stack, fuel supplier, electrical converters, controllers and so on. Each components of system should have appropriate specification for their applications as well as simplicity. Because thermal load can be managed simply by using fans without any water cooling system, the air-cooled PEMFC is widely used in sub kW and around 1kW systems. The performance of an air-cooled system is highly dependent on ambient temperature and humidity. In this paper, the air-cooled PEMFC systems are developed and investigated to study the operating characteristics in the aspect of the thermal and water coupled management by the control of the axial fans and compressors. Various experiments were also conducted to get the cell voltage distribution, the relative humidity of the reactant gas and the thermal management by axial cooling fans, which cannot be observed in single cell experiment. After then, as practical applications, portable fuel cell system and a hybrid electric cart were successfully integrated and operated by using this air-cooled stack.

  • PDF

Performance and Microbial Characteristics of Bio-hydrogen Production from Food Waste with Thermal Pre-treatment (음식물류 폐기물의 혐기성 수소 발효 시 열처리에 따른 성능 및 미생물 특성 평가)

  • Lee, Chaeyoung;Choi, Jaemin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • This study was conducted to investigate the effect of thermal pre-treatment on bio-hydrogen from food waste. Two continuous reactors operated and VFAs(volatile fatty acids) production and microbial communities were analyzed. The average hydrogen yield was 0.50 and 0.33mol $H_2/mol$ $hexose_{added}$ in thermally treated food added reactor(R1) and control(R2), respectively. Butyrate concentration was similarly 7,500mg/L in both reactors, but two times higher lactate concentration was observed in R2(3,800mg/L). The results of FISH(fluorescence in situ hybridization) showed that the relative microorganism to hydrogen producing bacteria was 78 and 27% in R1 and R2, respectively.

An Experimental Study of the Variation of the Moisture Content of Plywood and the Change of Thermal Conductivity of Plywood According to its Moisture Content (습도 조건에 따른 합판의 함수율 변화와 함수율에 따른 합판의 열전도율 변화에 대한 실험적 연구)

  • Lee, Jin-Sung;Kim, Kyung-Su;Kang, Jung-Kyoo;Yoo, Chang-hyuck
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.367-371
    • /
    • 2018
  • Plywood is one of the important materials in LNG cargo containment systems, and, due to the characteristics of the wood, its properties vary greatly depending on the humidity conditions in the storage facility. Due to the distribution environment of plywood, there is a high probability of long-term exposure to the domestic seasonal environment. Considering an environment in which the humidity changes greatly according to the seasons in Korea and the characteristics of the wood, it is necessary to acquire data on changes in the characteristics of the plywood for accurate quality control. In this study, the moisture content of plywood was determined experimentally to reflect the seasonal environmental conditions of shipyards in Korea. A noticeable change in the thermal conductivity was confirmed experimentally.

A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season (흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구)

  • Chan, Kook;Jeon, Ji-Hyeon;Shin, Yong-Gyu
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.

An Investigation of ESS(Environmental Stress Screening) Test of the DCS to be used for a thermal power plant. (발전소용 분산제어시스템의 스크리닝 시험에 관한 고찰)

  • Lee, J.H.;Ma, B.R.;Oh, Y.I.;Jung, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.871-873
    • /
    • 1999
  • According to the reports about the failure mode analysis of modules and systems, It is said that there are many early failure of system. To remove latent defects which causes early failures like that, It is necessary that screening test is performed. ESS is often used fur screening electronic equipments, and is proposed by the most powerful tool for removing latent defects of electronic equipments. [1][2] In this report, the procedure of the environmental stress screening which uses the temperature cycling stress is proposed. It is considered about environmental conditions of distributed control system(DCS) to be tested, design specifications of the system, recommended conditions of relative IEC-STD and applied conditions of similar company. ESS test was applied at the DCS to be installed in power plant. As the results of analyzing discovered problems. It was found that almost latent defects of electronic control systems was discovered early.

  • PDF

지지부 위치와 벽면 두께변화에 따른 구형 인공위성 추진제 탱크의 강도해석

  • 한근조;전언찬;김중완;안성찬;심재준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.528-532
    • /
    • 1997
  • The structure of satellite was of six parts of control system, power system, thermal control system, remote measurement command system, propellant system and thrust system. In these parts, propellant system consists of propellant tank and thrust device. What we want to perform is optimum design to minimaize the weight of propellant tank. In order to design optimal propellant tank, several parameters should be adopted form the tank geometry like the relative location of the lug and variation of the wall thickness. So the analysis was executed by finite element analysis for finding optimal design parameters. The structure was devided into 3 parts, the initial thickness zone, the transitional zone, and the weak zone,whose effects on the pressure vessel strength was investigated. Finally the optimal lug location and the three zone thickness were obtained and the weight was compared with the uniform thickness vessel.

  • PDF