• Title/Summary/Keyword: Relative Standard Deviation

Search Result 607, Processing Time 0.028 seconds

Analysis of Residual Solvents in Food Packaging Materials Using Solid Phase Microextraction Method (Solid Phase Microextraction법을 이용한 식품포장재 중의 잔류용제 분석)

  • 서택교;박상현;이윤수;김정한;권익부
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Solid phase microextraction (SPME) was used for the determination of 6 standard solvents (methanol, isopropanol, methyl ethyl ketone, ethyl acetate, cyclohexane, toluene) in food packaging materials. SPME method is a solvent-free sample preparation technique in which a fused silica fiber coated with polymeric organic liquid is introduced into the headspace above the sample. SPME method using fiber coated polydimethylisiloxane (PDMS) was compared with static headspace (SHS) method used as a reference. It was found that the optimal adsorption condition using PDMS-SPME method was 2$0^{\circ}C$ for 15 minutes for the standard solvents. Detection limits, linearity, reproducibility and recovery of both SHS and PDMS-SPME methods have been determined using 6 standard solvents. Both methods were characterized by high reproducibility and good linearity. Using SHS methods, the mean recovery of the 6 standard solvents was ranged from 75.5% to 105.8% with a mean relative standard deviation (RSD) of 0.3% to 4.8%. With PDMS-SPME method, the mean recovery of the 6 standard solvents was ranged from 86.7% to 108.3% with a mean RSD of 0.4% to 2.5%. The detection limits of both methods were the same for toluene, cyclohexane and methyl ethyl ketone; those of PDMS-SPME method were higher than those of SHS method for methanol, isopropanol and ethyl acetate. PDMS-SPME fiber shoed excellent adsorption for non-polar solvents such as toluene, while it showed relatively low adsorption for polar solvents such as methanol.

  • PDF

The Effect of Soft Handoff Techniques on Cell Coverage for CDMA Cellular System (소프트 핸드오프가 CDMA 셀룰러 시스템의 셀 영역에 미치는 영향)

  • Oh, Hyon-Kyu;Kim, Hang-Rae;Kim, Nam
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.125-128
    • /
    • 2000
  • In this paper, the handoff margins are analyzed using the propagation attenuation which is modeled as a product of the fourth power of the distant and a log-normal random variable whose standard deviation is 8 ㏈. The effect of handoff techniques on cell coverage for CDMA system are shown that soft handoff increases cell coverage relative to hard handoff. When the cell radius extends 5-10 % and the outage probability is 10 %, the relative cell coverage area is extended 3.22 ㏈-3.99 ㏈ and 2.55 ㏈-2.85 ㏈ with power control and without power control, respectively.

  • PDF

Armouring Effect on Local Scour around Bridge Piers (교각의 세굴에 미치는 Armouring 효과)

  • 이종규
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.107-115
    • /
    • 1993
  • The results of laboratory experiments on the clear-water local scour of cohesionless bed sediment at three types of the pier shape are presented. Based on the experimental data, the relative equilibrium depth of local scour is related to the pier shape, the geometric standard deviation of the bed material, the velocity ratio and the pier Froude number. The relative local scour depths were smallest ant the round-nosed pier and remarkably reduced at the non-uniform bed sediment, comparing with those at the uniform bed material. The effect of sediment grading on the local scour reduction was discussed and compared with Raudkivi and Ettema's experiments.

  • PDF

Determining the Relative Weights of Bias and Variance in Dual Response Surface Optimization (쌍대반응표면 최적화에서 편차와 분산의 가중치 결정에 관한 연구)

  • Jeong, In-Jun;Kim, Gwang-Jae;Jang, Su-Yeong;Lin, Dennis K.J.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.05a
    • /
    • pp.294-297
    • /
    • 2004
  • Mean squared error (MSE) is an effective criterion to combine the mean and the standard deviation responses in dual response surface optimization. The bias and variance components of MSE need to be weighted properly in the given problem situation. This paper proposes a systematic method to determine the relative weights of bias and variance in accordance with a decision maker's prior and posterior preference structure.

  • PDF

A Humidity Sensor Using an Electrochemically Prepared Poly(1,5-Diaminonaphthalene)Film

  • Park, Deong-Su;Shim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.241-248
    • /
    • 2003
  • An electrochemical humidity sensor was fabricated with poly(1,5-diaminonaphthalene) film coated on a gap of two splitted gold electrodes, which were made by vacuum deposition. Response currents according to humidity were measured by the potential sweep method and chronoamperometry. The stability of the polymer film was improved by double step chronoamperometry using the applied voltage of ${\pm}0.5$ Vdc. The response time determined by the pulse technique was about ${\sim}50$ msec and the relative standard deviation of current response was within ${\pm}5.0%$. The response current of the film was intrinsically humidity dependent. The film exhibited a non-linear but reproducible response in ordinary range of relative humidity. The linear equations were $I(nA)=0.28{\times}%RH-1.01$ between 10 to 70 %RH and $I(nA)=6.05{\times}%RH-403.21$ between 70 to 90 %RH.

A Study on Life Management Strategy and Variables of Unmarried Men and Women (미혼남녀의 생활관리전략과 관련변인 연구)

  • 이정숙
    • The Korean Journal of Community Living Science
    • /
    • v.14 no.1
    • /
    • pp.37-53
    • /
    • 2003
  • The purpose of this study was to empirically verify influence of objective variables and subjective variables of life management strategy of unmarried man and women and provide a basis for the development of time management. The subject of this study were 355 unmarried men and women and interviewed with a questionnaire. The data were analyzed by SPSS program for the frequency, mean, standard deviation, t-test and regression analysis. The major results of this study were as follows: 1. The score of time management strategy of unmarried man and women was the highest. The score of leisure management strategy of unmarried man and women was the lowest. 2. Variables that affect overall life management strategy were academic career, degree of information using, fate control orientation and perception level of living relative to others. 3. The relative contribution of subjective variables on life management strategy were higher than objective variables.

  • PDF

Temporal and Spatial correlation of Meteorological Data in Sumjin River and Yongsan River Basins (섬진강 및 영산강 유역 기상자료의 시.공간적 상관성)

  • 김기성
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.6
    • /
    • pp.44-53
    • /
    • 1999
  • The statistical characteristics of the factors related to the daily rainfall prediction model are analyzed . Records of daily precipitation, mean air temperature, relative humidity , dew-point temperature and air pressure from 1973∼1998 at 8 meteorological sttions in south-western part of Korea were used. 1. Serial correlatino of daily precipitaiton was significant with the lag less than 1 day. But , that of other variables were large enough until 10 day lag. 2. Crosscorrelation of air temperature, relative humidity , dew-point temperature showed similar distribution wiht the basin contrours and the others were different. 3. There were significant correlation between the meteorological variables and precipitation preceded more than 2 days. 4. Daily preciption of each station were treated as a truncated continuous random variable and the annual periodic components, mean and standard deviation were estimated for each day. 5. All of the results could be considered to select the input variables of regression model or neural network model for the prediction of daily precipitation and to construct the stochastic model of daily precipitation.

  • PDF

Magnetic Sector SIMS의 Sample Holder 위치에 따르는 RSF (Relative Sensitivity Factor) 변화 검증

  • 홍성윤;이종필;홍태은;윤명노;민경열;이순영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.192-192
    • /
    • 1999
  • SIMS(Secondary Ion Mass Spectrometry)는 다른 표면 분석장비와 비교하여^g , pp m,^g , pp b 단위의 미량분석이 가능한 장비로서, 특히 depth Profiling을 위한 dynamic SIMS는 Mass Spectrometer의 종류에 따라 Quadrupole SIMS (Q-SIMS)와, Magnetic Sector SIMS (M-SIMS)로 분류된다. 한편, Q-SIMS와 달리 M-SIMS의 경우, Transmission을 높여 주기 위해 Sample Holder에 수 keV의 bias를 걸어 주는데, 이로 인하여 분석 원소에 대한 Sensitivity가 향상되어 지는 반면, RSF의 변화와 같은 분석상의 Artifact가 발생하게 된다. 일반적으로 Q-SIMS의 경우에는 RSF의 RSD(Relative Standard Deviation)가 1%이내에서 보고되고 있지만 M-SIMS에 있어서는 이러한 Deviation이 M-SIMS보다 크게 나타난다. 이 차이는 주로 Sample Holder와 Immersion Lens 사이에 형성되는 Magnetic Field의 왜곡과 Spectrometer의 문제로부터 발생한다. 본 논문에서는 Sample Holder의 종류 및 holder so window 위치에 따라 RSF의 차이를 측정하고 그 data를 RS/1 통계 Package를 이용하여 계량적으로 검증하였으며, 그 차이의 원인과 대책을 제시하고자 한다. 실험에 사용된 Sample은 Si(100) p-type Wafer에 Boron을 이온 주입하여 제작하였다. 이온 주입 장비는 Varian E-500HP이며, 5.0E13 ions/cm2의 dose양을 80keV의 Energy로 각각 7도와 22도의 Tilt와 Twist Angle로 이온 주입을 하였다. SIMS분석에 사용된 Sample Holder는 각각 3 Hole, 9 Hole Type HOlder이며, 분석은 Cameca IMS-6f를 사용하여 B에 대한 Matrix Peak으로 28Si++를 얻었다. 실험 결과 3 Hole Type Sample Holder의 경우 RSF의 RSD는 5.84%, 9Hle Type Sample Holder의 경우는 14.3%로 나타났으나 분석 Window의 위치에 따르는 Grouping을 실시한 결과, 3 Hole Type Sample Holder의 경우 1.2%, 9Hole Type Sample Holder의 경우 9.8%로 RSF의 변화가 감소하였다. 이러한 Deviation은 Sample Holder를 Mount시킬 때 세 개의 Screw를 이용하여 Immersion Lens와의 평형을 잡아주기 때문에 발생하며, 이 Munting을 정확히 해줌으로써 RSF의 변화를 줄일 수 있으나, 실제로 완벽한 Mounting이 불가능하기 때문에 RSF를 일정하게 하기 위해서는 Sample Holder so Window의 취치를 일정하게 설정한 후 분석을 실시해야 한다고 판단된다.

  • PDF

Detection of voluminous gamma-ray source with a collimation beam geometry and comparison with peak efficiency calculations of EXVol

  • Kang, M.Y.;Sun, G.M.;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2601-2606
    • /
    • 2020
  • In this study, we expanded the performance of the existing EXVol code and performed empirical experiments and calculations. A high-resolution gamma spectroscopy system was constructed, and a standard point source and a standard volume source were measured with an HPGe detector with 43.1% relative efficiency. EXVol was verified by quantitative comparison of the detection efficiencies determined by measurements and calculations. To introduce the concept of the detector scanning that occurs in the actual measurement into the EXVol code, a collimator was placed between the source and detector. The detection efficiency was determined in the asymmetric arrangement of the source and detector with a collimator. A collimator made of lead with a diameter of 15 mm and a thickness of 50 mm was installed between the source and the detector to determine the detection efficiency at a specific location. The calculation result was contour plotted so that the distribution of detection efficiency could be visually confirmed. The relative deviation between the measurements and calculations for the coaxial and asymmetric structures was 10%, and that for the collimation structure was 20%. The results of this study can be applied to research using γ-ray measurements.

Determination of Trace Elements in Airborne Particulates by Instrumental Neutron Activation Analysis (중성자 방사화분석법을 이용한 대기분진시료의 정량)

  • Chung, Yong-Sam;Chung, Young-Ju;Jeong, Eui-Sik;Cho, Seung-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.234-247
    • /
    • 1995
  • Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis (INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux 1$\times$10$^{13}$ n/$\textrm{cm}^2$.s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 ore chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different counties. In the analytical result of two or both of standard reference materials, relative standard deviation wes within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at too different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources.

  • PDF