• Title/Summary/Keyword: Relationship values

Search Result 3,642, Processing Time 0.023 seconds

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

The Standing Crops and Soil-borne Microfungal Flora of Phyllostachys reticulata in Korea (한국산(韓國産) 왕대나무의 현존량(現存量)과 토양(土壤) 미세균류상(微細菌類相))

  • Kim, Kwan-Soo
    • The Korean Journal of Mycology
    • /
    • v.7 no.2
    • /
    • pp.91-116
    • /
    • 1979
  • This paper is to investigate the standing crops and microfungal flora in soil in Phyllostachys reticulata forests in both the Yesan area (A) and the Kwangsan area (B). The stand density of the bamboo revealed 17,250 shoots per ha in area A, and in area B 14,780 shoots which were 16.1% less in number than area A. In respect to the environmental factors between the two areas, the mean temperature during the growth period was $1.5{\sim}2^{\circ}C$ higher in area B than in area A, soil tempeature also was $1{\sim}2^{\circ}C$ higher in area B, and the total quantities of nitrogen, phosphoric acid and organic compounds contained in the soil of area B were also slightly higher than those of area A. In area B the quantities of dried leaf matter, humus, and vegetation in the bamboo forest were also larger than in area A. In addition, five more species of microfungi which playa role in the decomposition of the various organic materials in the bamboo forests were identified in area B: Mortierella elongata, Mucor circinelloides, Aspergillus japonicus, Penicillium waksmani and Trichoderma lignorum. The atmospheric temperature in the inner portions of the bamboo forests was lower than the outside temperature, but the humidity was higher. The rates of relative illuminance were measured in area A at 4.19%, and in area B at 2.7%. These values revealed that the photosynthetic acitivity in the lower part of the bamboo was lost but it was considered that lower illuminance increased the microfungal activities in the vicinity of the surface soil. Since the productive structure of the bamboo showed that the maximum amount of photosynthesis was located in the upper portion of the bamboo in area B, it was considered to be an effective structure in maintaining the high productivity of the bamboo. The allometric relation between $D^2H$ and dry weight of stems(Ws), branches(Wb) and leaves(Wl) of the bamboo in area A were appoximated by log Ws=0.5262 log $D^2H$+1.9546; log Wb=0.6288 log $D^2H$+1.5723; log Wl=0.5181 log $D^2H$+1.8732, and those of the bamboo in area B were approximated by log Ws=0.5433 log $D^2H$+1.8610; log Wb=0.1630 log $D^2H$+2.3475; log Wl=0.4509 log $D^2H$+2.0041. From the above, the standing crops in area A were measured thus: Ws was 1,128. 83kg; Wb, 689.05kg; Wl, 926.69kg and Wl, 2,744.57kg per 10a. In area B, Ws was 1,206. 66kg; Wb, 679.92kg; Wl, 1,112.51kg and Wt, 2.999kg per l0a. Significant differences from the result of t-test were for $D^2H$ Ws, Wl and Wt between areas A and B. But no significant difference was found for Wb. In order to record as completely as possible the microfungal flora of the areas, every possible means was tried, and 158 strains of fungi were isolated, and of these, the microfungi of 55 species were identified. The dominant species were Trichoderma viride, Penicillium janthinellum, P. commune, Aspergillus oryzae, A. niger, A. gigantus, A. fumigatus, Mortierella ramaniana, var. anguliFPora, Mucor hiemalis and Zygorhynchus moelleri. According to the above results, it was revealed that optimum soil, the increases of soil materials, more species of soil microfungi, and the atmospheric temperature during the growth period have made the bamboo flourish and bring more species and larger quantities of vegetation in the bamboo forests. The correlation between the standing crops and environmental factors in the bamboo forest is considered to be a complicated relationship of all the factors, but the stand density is thought to be the most important factor involved.

  • PDF