• Title/Summary/Keyword: Rehabilitation robot

Search Result 190, Processing Time 0.027 seconds

A Study on the Multi-Joint Rehabilitation System of an Industrial Robot

  • Lee, Yong-Seok;Jang, Jae-Ho;Sim, Hyung-Joon;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.92-95
    • /
    • 2004
  • This study proposes an industrial rehabilitation robot system which can exercise two joints in 3 dimensional spaces. The robot kinematics analysis and the results of studies on each joint for the rehabilitation robot could verify possibility of rehabilitation motion to exercise a joint. The force and torques sensor not only measures a rehabilitation performance of subjects between the abnormal limb and the manipulator, but also carries out an important function of safety device to prevent accidents. Also, limit sensors and emergency stop switch are used for high safety in this system. In this real test, the possibility of rehabilitation robot system is evaluated by C&R ARM I which is similar to upper-limb.

  • PDF

Development of a Rehabilitation Robot for Mckenzie Cervical Exercise (경부 맥킨지 운동용 재활로봇의 개발)

  • Shin, Sang-Hyo;Moon, Inhyuk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.73-79
    • /
    • 2016
  • In this paper a cervical rehabilitation robot for Mckenzie exercises to be effective to neck pain relief is proposed. The robot has two degrees of freedom (DOF) for Lateral flexion and extension, Dorsal and Vental flexion which enable user to perform cervical stretching and isometric exercises for neck muscles. The mechanical parts of the cervical rehabilitation robot can be mounted on a back- or head-rest of chair, and user can perform the Mckenzie exercise with seated. In experiments we measured the range of motion of cervical part, EMG signals from neck muscles and the contact forces of a head bracket fixing the head part of user, and then evaluated their performances. From the experimental results, we showed a feasibility of the cervical rehabilitation robot proposed in this study.

A Study on the Multi-Purpose Rehabilitation System for the Upper Limb Using a Robot Manipulator (로봇을 이용한 다기능 상지 재활 시스템에 관한 연구)

  • 원주연;심형준;박범석;한창수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.171-179
    • /
    • 2003
  • This paper presents a rehabilitation exercise system which utilizes a 6 DOF robot as a motion generator. This system was proposed for a stroke patient or a patient who has hemiplegia. A master-slave system was designed to exercise either paralysis or abnormal limb by using normal limb motion. The study on the human body was applied to calculate the motion range of elbows and shoulders. In addition, a force-torque sensor was applied to the slave robot to estimate the rehabilitation extent of the patient. Therefore, the stability of the rehabilitation robot could be improved. By using the rehabilitation robot. the patients could exercise by themselves without assistance. In conclusion, the proposed system was verified by computer simulations and system experiment.

Development of a 3-D Rehabilitation Robot System for Upper Extremities (상지 재활을 위한 3-D 로봇 시스템의 개발)

  • Shin, Kyu-Hyeon;Lee, Soo-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.64-71
    • /
    • 2009
  • A 3-D rehabilitation robot system is developed in this paper. The robot system is for the rehabilitation of upper extremities, especially the shoulder and elbow joints, and has 3-D workspace for enabling occupational therapy to recover physical functions in activities of daily living(ADL). The rehabilitation robot system, which is driven by actuators, has 1 DOF in horizontal rotational motion and 2 DOF in vertical rotational motion, where all actuators are set on the ground. Parallelogram linkage mechanisms lower the equivalent inertia of the control elements as well as control forces. Also the mechanisms have high mechanical rigidity for the end effector and the handle. Passive motion mode experiments have been performed to evaluate the proposed robot system. The results of the experiments show and excellent performance in simulating spasticity of patients.

Challenges in neuro-machine interaction based active robotic rehabilitation of stroke patients

  • Song, Aiguo;Yang, Renhuan;Xu, Baoguo;Pan, Lizheng;Li, Huijun
    • Advances in robotics research
    • /
    • v.1 no.2
    • /
    • pp.155-169
    • /
    • 2014
  • Study results in the last decades show that amount and quality of physical exercises, then the active participation, and now the cognitive involvement of patient in rehabilitation training are known of crux to enhance recovery outcome of motor dysfunction patients after stroke. Rehabilitation robots mainly have been developing along this direction to satisfy requirements of recovery therapy, or focusing on one or more of the above three points. Therefore, neuro-machine interaction based active rehabilitation robot has been proposed for assisting paralyzed limb performing designed tasks, which utilizes motor related EEG, UCSDI (Ultrasound Current Source Density Imaging), EMG for rehabilitation robot control and feeds back the multi-sensory interaction information such as visual, auditory, force, haptic sensation to the patient simultaneously. This neuro-controlled and perceptual rehabilitation robot will bring great benefits to post-stroke patients. In order to develop such kind of robot, some key technologies such as noninvasive precise detection of neural signal and realistic sensation feedback need to be solved. There are still some grand challenges in solving the fundamental questions to develop and optimize such kind of neuro-machine interaction based active rehabilitation robot.

Development of the Pipe Construction Robot for Rehabilitation Work Process of the Water Pipe Lines (상수도 배관의 갱생 공정을 위한 배관 건설 로봇 개발)

  • Jeong, Myeong-Su;Lee, Jaeyoul;Hong, Sung-Ho;Jang, Minwoo;Shin, Dongho;Hahm, Jehun;Seo, Kap-Ho;Seo, Jin-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.3
    • /
    • pp.223-231
    • /
    • 2021
  • In this paper describes the research and development of a pipe robot for pipe rehabilitation construction of old water pipes. After the water supply pipe construction, the pipe is leaking, damaged, and aging due to corrosion. Eventually, resistance to the flow of water in lower supply efficiency and contaminated water such as rusty water, finally in various consumer complaints. In order to solve this problem, rehabilitation construction robot technology is required to secure the construction quality of pipe rehabilitation construction and restore the function of the initial construction period. The developed pipe rehabilitation construction robot required a hydraulic actuator for high traction and was equipped with a small hydraulic supply device. In addition, we have developed a hydraulic cylinder and a link system that supports the pipe inner diameter to develop a single pipe robot corresponding to 500 to 800mm pipe diameter. The analysis and experimental verification of the driving performance and unit function of the developed pipe reconstruction robot are explained, and the result of the integrated performance test of the pipe reconstruction robot at the water supply pipe network site is explained.

Design of Six-Axis Force/Moment Sensor for Ankle-Rehabilitation Robot (발목재활로봇을 위한 6축 힘/모멘트센서 설계)

  • Kim, Yong-Gook;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.357-363
    • /
    • 2013
  • Most serious patients who have the paralysis of their ankles can't use of their feet freely. But their ankles can be recovered by an ankle bending rehabilitation exercise and a ankle rotating rehabilitation exercise. Recently, the professional rehabilitation therapeutists are much less than stroke patients in number. Therefore, the ankle-rehabilitation robot should be developed. The developed robot can be dangerous because it can't measure the applied bending force and twisting moment of the patients' ankles. In this paper, the six-axis force/moment sensor for the ankle-rehabilitation robot was specially designed the weight of foot and the applied force to foot in rehabilitation exercise. As a test results, the interference error of the six-axis force/moment sensor was less than 2.51%. It is thought that the sensor can be used to measure the bending force and twisting moment of the patients' ankles in rehabilitation exercise.

Comfort Evaluation by Wearing a Gait-Assistive Rehabilitation Robot (보행보조 재활 로봇 착용에 따른 쾌적성 평가)

  • Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1107-1119
    • /
    • 2020
  • This study analyzed a subject's body reaction and subjective sensation when wearing a gait-assistive rehabilitation robot. The research method measured skin and clothing surface temperatures for 'seating-standing' and 'walking in place' exercises after wearing a gait-assistive rehabilitation robot. In addition, subjective sensation and satisfaction were evaluated on a 7-point Likert scale. The study results showed that the average skin temperature during exercise while wearing the gait-assistive rehabilitation robot was within a comfortable range. However, during the 'seating-standing' exercise, the skin temperature was slightly lowered. Additionally, the clothing surface temperature tended to be lower than the pre-exercise temperature after all exercises. The subjective sensation evaluation results showed that the wear comfort of the waist part was low during mobility/activity. In addition, an overall improvement in the wear comfort of the robot is necessary. The short-time movement of wearing and walking in the gait-assistive rehabilitation robot did not interfere with the thermal comfort of the body. However, the robot needs to be ergonomically improved in consideration of the long wearing time along with improved material that to satisfy overall wearing comfort.

Control and VR Navigation of a Gait Rehabilitation Robot with Upper and Lower Limbs Connections (상하지가 연동된 보행재활 로봇의 제어 및 VR 네비게이션)

  • Novandy, Bondhan;Yoon, Jung-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.315-322
    • /
    • 2009
  • This paper explains a control and navigation algorithm of a 6-DOF gait rehabilitation robot, which can allow a patient to navigate in virtual reality (VR) by upper and lower limbs interactions. In gait rehabilitation robots, one of the important concerns is not only to follow the robot motions passively, but also to allow the patient to walk by his/her intention. Thus, this robot allows automatic walking velocity update by estimating interaction torques between the human and the upper limb device, and synchronizing the upper limb device to the lower limb device. In addition, the upper limb device acts as a user-friendly input device for navigating in virtual reality. By pushing the switches located at the right and left handles of the upper limb device, a patient is able to do turning motions during navigation in virtual reality. Through experimental results of a healthy subject, we showed that rehabilitation training can be more effectively combined to virtual environments with upper and lower limb connections. The suggested navigation scheme for gait rehabilitation robot will allow various and effective rehabilitation training modes.

NREH: Upper Extremity Rehabilitation Robot for Various Exercises and Data Collection at Home (NREH: 다양한 운동과 데이터 수집이 가능한 가정용 상지재활로봇)

  • Jun-Yong Song;Seong-Hoon Lee;Won-Kyung Song
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.376-384
    • /
    • 2023
  • In this paper, we introduce an upper extremity rehabilitation robot, NREH (NRC End-effector based Rehabilitation arm at Home). Through NREH, stroke survivors could continuously exercise their upper extremities at home. NREH allows a user to hold the handle of the end-effector of the robot arm. NREH is a end-effector-based robot that moves the arm on a two-dimensional plane, but the tilt angle can be adjusted to mimic a movement similar to that in a three-dimensional space. Depending on the tilting angle, it is possible to perform customized exercises that can adjust the difficulty for each user. The user can sit down facing the robot and perform exercises such as arm reaching. When the user sits 90 degrees sideways, the user can also exercise their arms on a plane parallel to the sagittal plane. NREH was designed to be as simple as possible considering its use at home. By applying error augmentation, the exercise effect can be increased, and assistance force or resistance force can be applied as needed. Using an encoder on two actuators and a force/torque sensor on the end-effector, NREH can continuously collect and analyze the user's movement data.