• Title/Summary/Keyword: Registration Correction

Search Result 65, Processing Time 0.028 seconds

A NEW METHOD OF MASKING CLOUD-AFFECTED PIXELS IN OCEAN COLOR IMAGERY BASED ON SPECTRAL SHAPE OF WATER REFLECTANCE

  • Fukushima, Hajime;Tamura, Jin;Toratani, Mitsuhiro;Murakami, Hiroshi
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.25-28
    • /
    • 2006
  • We propose a new method of masking cloud-affected pixels in satellite ocean color imageries such as of GLI. Those pixels, mostly found around cloud pixels or in scattered cloud area, have anomalous features in either in chlorophyll-a estimate or in water reflectance. This artifact is most likely caused by residual error of inter-band registration correction. Our method is to check the pixel-wise 'soundness' of the spectral water reflectance Rw retrieved after the atmospheric correction. First, we define two spectral ratio between water reflectance, IRR1 and IRR2, each defined as RW(B1)/RW (B3) RW (B3) and as RW (B2)/RW(B4) respectively, where $B1{\sim}B4$ stand for 4 consecutive visible bands. We show that an almost linear relation holds over log-scaled IRR1 and IRR2 for shipmeasured RW data of SeaBAM in situ data set and for GLI cloud-free Level 2 sub-scenes. The method we propose is to utilize this nature, identifying those pixels that show significant discrepancy from that relationship. We apply this method to ADEOS-II/GLI ocean color data to evaluate the performance over Level-2 data, which includes different water types such as case 1, turbid case 2 and coccolithophore bloom waters.

  • PDF

Development and Performance Analysis of a Near Real-Time Sensor Model Correction System for Frame Motion Imagery (프레임동영상의 근실시간 센서모델 보정시스템 개발 및 성능분석)

  • Kwon, Hyuk Tae;Koh, Jin-Woo;Kim, Sanghee;Park, Se Hyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.315-322
    • /
    • 2018
  • Due to the increasing demand for more rapid, precise and accurate geolocation of the targets on video frames from UAVs, an efficient and timely method for correcting sensor models of motion imagery is required. In this paper, we propose a method to adjust or correct sensor models of motion imagery frames using space resection via image matching with reference data. The proposed method adopts image matching between the motion imagery frames and the reference frames which are synthesized from reference data. Ground or reference control points are generated or selected through the matching process in near real time, and are used for space resection to get adjusted sensor models. Finally, more precise and accurate geolocation of the targets can possibly be done on the fly, and we have got the promising result on performance analysis in terms of the geolocation quality.

The Research for the Wide-Angle Lens Distortion Correction by Photogrammetry Techniques (사진측량 기법을 사용한 광각렌즈 왜곡보정에 관한 연구)

  • Kang, Jin-A;Park, Jae-Min;Kim, Byung-Guk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.2
    • /
    • pp.103-110
    • /
    • 2008
  • General lens, widely using in Photogrammetry, has narrow view, and have to adjust "Image-Registration Method" after obtain images and it need cost; economic, period of time. Recent days, there is various study that use wide-angle lens, usually for robotics field, put to practical use in photogrammetry instead of general lens. In this studies, distortion tendency of wide-angle lens and utilize the correction techniques suitable to wide-angle lens by the existing photographic survey methods. After carrying out the calibration of the wide-angle lens, we calculated the correction parameters, and then developed the method that convert the original image-point to new image-point correcting distortion. For authorization the developed algorithm, we had inspection about shape and position; there are approximately 2D RMSE of 3 pixel, cx = 2, and cy = 3 different.

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

Orbit Determination Accuracy Improvement for Geostationary Satellite with Single Station Antenna Tracking Data

  • Hwang, Yoo-La;Lee, Byoung-Sun;Kim, Hae-Yeon;Kim, Hae-Dong;Kim, Jae-Hoon
    • ETRI Journal
    • /
    • v.30 no.6
    • /
    • pp.774-782
    • /
    • 2008
  • An operational orbit determination (OD) and prediction system for the geostationary Communication, Ocean, and Meteorological Satellite (COMS) mission requires accurate satellite positioning knowledge to accomplish image navigation registration on the ground. Ranging and tracking data from a single ground station is used for COMS OD in normal operation. However, the orbital longitude of the COMS is so close to that of satellite tracking sites that geometric singularity affects observability. A method to solve the azimuth bias of a single station in singularity is to periodically apply an estimated azimuth bias using the ranging and tracking data of two stations. Velocity increments of a wheel off-loading maneuver which is performed twice a day are fixed by planned values without considering maneuver efficiency during OD. Using only single-station data with the correction of the azimuth bias, OD can achieve three-sigma position accuracy on the order of 1.5 km root-sum-square.

  • PDF

Esthetic Consideration on Genioplasty (하악골 정중부 수평 골절단술 시행시 심미적 고찰)

  • Cho, Byong-Ouck;Nam, Jong-Hoon;Lee, Young-Ho
    • The Journal of the Korean dental association
    • /
    • v.25 no.9 s.220
    • /
    • pp.847-854
    • /
    • 1987
  • Genioplasty may considerably change a person's face which needs surgical correction of deformed chin. Comprehensive treatment planning is therefore decisive for the treatment to be successful. A three-dimensional analysis of chin relative to cranial base, upper and lower jaws using the frontal and lateral facial photographs and cephalographs permits classification of the defective chin position and provides a basis for operation planning and deciding upon the operation method. A chin miniplate system has been developed for intraoperative registration securing the sagittal, vertical and horizontal position of the osteotomized chin and ould reduce the relapse rate.

  • PDF

Statistical Issues in Genomic Cohort Studies (유전체 코호트 연구의 주요 통계학적 과제)

  • Park, So-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.2
    • /
    • pp.108-113
    • /
    • 2007
  • When conducting large-scale cohort studies, numerous statistical issues arise from the range of study design, data collection, data analysis and interpretation. In genomic cohort studies, these statistical problems become more complicated, which need to be carefully dealt with. Rapid technical advances in genomic studies produce enormous amount of data to be analyzed and traditional statistical methods are no longer sufficient to handle these data. In this paper, we reviewed several important statistical issues that occur frequently in large-scale genomic cohort studies, including measurement error and its relevant correction methods, cost-efficient design strategy for main cohort and validation studies, inflated Type I error, gene-gene and gene-environment interaction and time-varying hazard ratios. It is very important to employ appropriate statistical methods in order to make the best use of valuable cohort data and produce valid and reliable study results.

Automatic Stitching of the Prostate in Pathology Image Using Position Correction and Rigid Registration (위치 보정 및 강체 정합을 통한 전립선 병리 영상의 자동 스티칭)

  • Lee, Ji-Un;Jung, Ju-Lip;Hong, He-Len
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06c
    • /
    • pp.469-473
    • /
    • 2010
  • 본 논문에서는 조각 병리 영상을 강체 정합을 통해 하나의 영상으로 자동 스티칭하는 방법을 제안한다. 제안 방법은 영상의 위치 초기화, 위치 보정, 강체 정합의 세 단계로 이루어진다. 첫째, 영상의 위치 초기화 단계에서는 순서 없이 흩어진 부분 영상을 탬플릿 매칭 기법을 사용한 영상 내 문자 인식을 통해 위치를 초기화한다. 둘째, 강체 정합의 정확성을 높이기 위해 코너점을 이용해 부분 영상의 위치를 보정한다. 셋째, 조각 영상 간 거리를 최소화하는 강체 정합을 수행한다. 실험 결과, 부분 영상 간 간격이 최소화되어 하나의 영상으로 스티칭되는 것을 확인하였고, 최적화 반복 횟수와 변환 벡터에 따른 정확성, 견고성 평가를 통해 거리 차의 제곱 합이 최소화되어 수렴됨을 알 수 있었다. 본 논문의 제안 방법은 조각 영상을 하나의 영상으로 스티칭함으로써 병리 조직의 전체적인 구조 파악과 이를 이용한 전립선암 확진에 사용될 수 있다.

  • PDF

MR-based Partial Volume Correction Using Hoffman Brain Phantom Data and Clinical Application (자기공명영상을 이용한 양전자방출단층촬영의 부분용적효과 보정 및 임상적용)

  • 김동현;이상호;정해조;윤미진;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.203-210
    • /
    • 2003
  • PET (positron emission tomography) permits the investigation of physiological and biochemical processes in vivo. The accuracy of quantifying PET data is affected by its finite spatial resolution, which causes partial volume effects. In this study, we developed a method for partial volume correction using Hoffman phantom PET and MR data, and applied various FWHM (full width at half maximum) levels. We also applied this method to PET images of normal controls and tested for the possibility of clinical application. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices. The gray matter and white matter regions were then segmented into binary images. Each binary image was convolved by 4, 8, 12, 16 mm FWHM levels. These convolved images of gray and white matter were merged corresponding to the same level of FWHM. The original PET images were then divided by the convolved binary images voxel-by-voxel. These corrected PET images were multiplied by binary images. The corrected PET images were evaluated by analyzing regions of interests, which were drawn on the gray and white matter regions of the original MR image slices. We calculated the ratio of white to gray matter. We also applied this method to the PET images of normal controls. On analyzing the corrected PET images of Hoffman phantom, the ratios of the corrected images increased more than that of the uncorrected images. With the normal controls, the ratio of the corrected images increased more than that of the uncorrected images. The ratio increase of the corrected PET images was lower than that of the corrected phantom PET images. In conclusion, the method developed for partial volume correction in PET data may be clinically applied, although further study may be required for optimal correction.

  • PDF

Digital Conversion of Analogue Cadastral Maps of Kathmandu Metropolitan City

  • Baral, Toya Nath;Acharya, Babu Ram;Subedi, Nab Raj
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.973-977
    • /
    • 2003
  • Land is the only immovable property that can be used, as a means for agricultural production as well as a means for mortgage for financing industrial or commercial enterprises. Spatial technologies play a key role in managing our land, water and natural resources. Cadastral data is a major component for the development of Land Information System. Therefore, systematic land registration system based on accurate and scientific cadastral map are found inevitable for poverty alleviation, good governance and women empowerment through security of their rights on property, as well as the planning and development of a sustainable environmental protection within Metropolitan city. Digital cadastral parcel is the fundamental spatial unit on which database is designed, created, maintained and operated. Availability of accurate and updated cadastral maps is a primary requisite for successful planning, policy formulating and maintenance of city utility services, which need cadastral and utility information together. Flawed cadastral maps can put land, revenue and taxation system at stake. Kathmandu the capital city of Nepal still is lacking utility maps combining cadastral information with the utility. There is an urgent need to have an effective, accurate and easy to access land revenue and utility services system within the urban areas which could be achieved after the production of reliable base maps and land registration system to guarantee land allocation and property rights which can well be achieved by digital conversion and correction of base cadastral maps. This paper highlights the drawbacks of the conventional cadastral maps and the possible advantages of digital cadastral maps over these. Also the problems, issues and implications during digital conversion and creating database of the same will be discussed.

  • PDF