• Title/Summary/Keyword: Regeneration power

검색결과 237건 처리시간 0.021초

엘리베이터 회생전력을 이용한 하이브리드 태양광 연계형 인버터에 관한 연구 (A Study on Hybrid type Grid-Connected PV Inverter using Elevator Regeneration Power)

  • 조수억
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1682-1687
    • /
    • 2016
  • Approximately 520thousand elevators are operating now in Korea, about 40% ~ 60% of the elevator power is generated. In this paper, by using the method of adding regeneration power of the elevator to the grid-tied photo voltaic inverter, PV generation that was dependant on the solar radiation was significantly improved. In order to confirm this, the regeneration power of the elevator has been simulated in 12% of the rating load, and measured the regeneration power of the elevator in the actual condition to assess the differences of it. The 5[kW] hybrid grid-tied photo voltaic invertor has been fabricated to conduct an experiment for the confirmation of the proposing method. The effectiveness of the proposing method has been reassured with the result of experiment that include the transfer interface part of the regeneration power of the elevator.

로드휠의 슬립을 고려한 군용 궤도차량의 조향특성에 관한 연구 (The Steering Characteristics of Military Tracked Vehicles with Considering Slippage of Roadwheel)

  • 임원식;윤재섭;강상욱
    • 한국자동차공학회논문집
    • /
    • 제17권2호
    • /
    • pp.57-66
    • /
    • 2009
  • In this paper, the steering characteristics of tracked vehicles are studied for the improvement of steering performance. The important design factor of military vehicles is high mobility. It is influenced by weight of a vehicle, engine capacity, power-train, and steering system. The military vehicle, which is equipped with caterpillar, has unique steering characteristics and is quite different from that of a wheeled vehicle. The steering of tracked vehicles is operated in the power pack due to different speeds of both sprockets. Under cornering conditions, power split and power regeneration are happened in the power pack. In case of power regeneration, power is transferred outside track after adding engine power and power inputted inside track from the ground. However, excessive power regeneration is transferred in the power pack. It damages mechanical elements. Therefore, it is necessary to analyze the steering system and check mentioned problem above. In this study, the detailed dynamic model of steering system is presented, which includes slippage between track and roadwheel, inertia force, and inertia moment. Finally, our model is compared with the Kitano model and we verified the validity of the model.

DC전철구간의 에너지회생장치 개발 방향 (Direction for Development of Energy Regeneration Device for DC Electric Railway System)

  • 김용기;배창한;한문섭;양영철;장수진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

고조파 저감 능력을 가진 회생용 인버터 시스템 연구 (A study of regenerative inverter system with capability of harmonic reduction)

  • 최창열;배창환;장수진;송상훈;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.443-448
    • /
    • 2005
  • This paper proposed a regeneration inverter system, which can regenerate the excessive power form dc bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are include to ac current source. The regenerative inverter is operated as two modes. As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In the paper, a regeneration inverter used PWM DC/AC converter algorithm. And an active power filter used p-q theory. The simulation was composed as a prototype model[3kW]. Simulation results show that two algorithm can be used to real model[100kW]. Finally, the inverter was successfully operated as regeneration mode.

  • PDF

Implementation of Inverter Systems for DC Power Regeneration

  • Kim Kyung-Won;Yoon In-Sic;Seo Young-Min;Hong Soon-Chan;Yoon Duck-Yong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.126-131
    • /
    • 2001
  • This paper deals with implementation of inverter systems for DC power regeneration, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, a three-phase square-wave inverter system is adopted. To control the regenerated power, the magnitude and phase of fundamental output voltages should be appropriately controlled in spite of the variation of input DC voltage. Inverters are operated with modified a-conduction mode to fix the potential of each arm. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified $\alpha-conduction\;mode\;with\;\delta\;and\;\alpha$, a DPLL for frequency followup, and power circuit.

  • PDF

능동전력필터를 가진 지하철 회생인버터 시스템 (A Regeneration Inverter for Traction Applications with a Active Power Filter)

  • 원충연;장수진;김연충;이병국;배창한;김용기
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.25-32
    • /
    • 2006
  • 본 논문에서는 전철시스템의 직류모선에 발생하는 잉여분의 전력을 교류전원 측으로 회생시킬 수 있는 회생인버터시스템을 제안한다. 제안된 직류 전철용 회생인버터 시스템은 교류 전원 측 전류에 포함되어진 고조파를 제거할 수 있는 기능을 추가하였다. 회생인버터 모드에서는 전철의 감속에 의해 회생되는 에너지를 재사용할 수 있으며, 능동전력필터 모드에서는 정류기에 의해 발생되는 고조파 왜곡을 보상할 수 있다. 논문에서 회생용 인버터는 PWM DC/AC 인버터 알고리즘을 사용하였으며, 능동전력필터는 p-q 이론을 사용하였다. 시뮬레이션은 축소모델[3.7kW]과 동일하게 구성되었다. 시뮬레이션과 실험 결과로부터 두 가지 알고리즘이 실 모델[100kW]에서도 적용되어질 수 있음을 증명하였다.

BLDCM의 회생제동을 위한 스위칭 방식에 관한 연구 (Research of PWM Modulation for Regeneration Braking of BLDC Motor)

  • 김용휴;박성준;정준형;김동윤;김장목
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.193-199
    • /
    • 2015
  • This paper proposes a regeneration braking algorithm for Brushless DC (BLDC) motor system. The unipolar switching method has a limitation about the regeneration braking when the BLDC motor is operated in the low speed region. The proposed algorithm alternatively utilizes the unipolar and bipolar switching method to implement the regeneration braking for overall speed range. The bipolar switching method is used when the BLDC motor is operated in the low speed region. The switching transition point is determined by analyzing the unipolar and bipolar switching during the regeneration braking. The effectiveness of proposed algorithm is verified by using the experimental results.

직류전철용 에너지 회생장치 성능개선 (Improving the capability of energy regeneration inverter for dc electric traction system)

  • 방효진;김용기;장수진;송상훈;안규복;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.104-109
    • /
    • 2004
  • Recently, when electric traction system used DC 1500[Vdc] runs on decline of rail road track and slows down, dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. Therefore this paper proposes that the extra power is regenerated through regeneration inverter to AC utility in result this system obstruct to go beyond regular voltage and improve the efficiency. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality.

  • PDF

Design of Bootstrap Power Supply for Half-Bridge Circuits using Snubber Energy Regeneration

  • Chung, Se-Kyo;Lim, Jung-Gyu
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.294-300
    • /
    • 2007
  • This paper deals with a design of a bootstrap power supply using snubber energy regeneration, which is used to power a high-side gate driver of a half-bridge circuit. In the proposed circuit, the energy stored in the low-side snubber capacitor is transferred to the high-side bootstrap capacitor without any magnetic components. Thus, the power dissipation in the RCD snubber can be effectively reduced. The operation principle and design method of the proposed circuit are presented. The experimental results are also provided to show the validity of the proposed circuit.

직류전철용 전력공급 장치의 에너지희생에 관한 연구 (A study on energy regeneration of power supply for DC electric traction system)

  • 방효진;장수진;송상훈;원충연;김용기;안규복
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.439-442
    • /
    • 2004
  • This paper described a dc power system, which can generate the excessive do power form do bus line to ac source in substation for traction system. The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation.

  • PDF