• 제목/요약/키워드: Refuge floor

검색결과 8건 처리시간 0.018초

초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구 (A Study on the Improvement of the Refuge safety area in High-rise Buildings Type)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

초고층 건축물 화재시 피난공간 기준 제안에 관한 연구 (A Study on Proposal of the Refuge Area Standard in Super-High-Rise Building Fire)

  • 박상규;노삼규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.76-79
    • /
    • 2008
  • 본 연구에서는 초고층 건축물에서의 화재 발생시 피난상의 문제점을 분석하여 재실자의 안전을 도모할 수 있는 수단으로서 피난공간을 제시하고 필요성을 고찰하였다. 또한 피난공간의 기준 마련을 위해서 고려해야 할 인자들을 도출하고 도출된 인자들을 각각의 해결방안에 의한 논증을 통해 피난공간의 기준을 제안하였다.

  • PDF

오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구 (A Study on Improvement According to Korea and China Evacuation Laws in Office Building)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구 (Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control)

  • 이재빈;문주현;이성혁;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2011
  • 본 연구에서는 초고층 건축물 화재 시 피난 안전 구역이 있는 피난 층에서 화재실로부터 발생하는 연기의 거동을 파악하기 위하여 상용코드를 사용하여 수치해석을 하였다. 화재를 모사하기 위하여 10 MW의 발열량에 해당하는 온도와 속도를 이용하여 부력 plume을 적용하였으며 종 보존 방정식을 이용하여 화재 연기 거동을 예측하였다. 피난 안전 구역에 제연 댐퍼를 설치하여 급기 가압 제연 시스템을 적용하였으며 화재실 문이 열린 경우 25 $m^3/s$, 화재실과 부속실 문이 동시에 열린 경우 50 $m^3/s$의 제연 댐퍼송풍량은 화재 안전 기준 NFSC 501-A를 만족하며 충분히 제연이 가능하다는 것을 확인하였다. 부속실문이 열린 경우, 화재실의 문이 닫혀 있더라도 문과 벽 사이의 틈새 면적으로 연기가 피난 안전 구역으로 유입될 가능성이 있다. 또한, 50 $m^3/s$ 높은 송풍량으로 제연 중 화재실 문이 닫힐 경우 피난자가 화재실에 고립될 가능성을 확인하였다. 그러므로 피난자의 안전을 위해 제연 송풍량의 조절이 필요하며 본 연구에서는 피난 시나리오에 따른 적절한 송풍량을 제안한다.

Effect of a through-building gap on wind-induced loading and dynamic responses of a tall building

  • To, Alex P.;Lam, K.M.;Wong, S.Y.;Xie, Z.N.
    • Wind and Structures
    • /
    • 제15권6호
    • /
    • pp.531-553
    • /
    • 2012
  • Many tall buildings possess through-building gaps at middle levels of the building elevation. Some of these floors are used as sky gardens, or refuge floors, through which wind can flow with limited blockage. It has been reported in the literature that through-building gaps can be effective in reducing across-wind excitation of tall buildings. This paper systematically examines the effectiveness of two configurations of a through-building gap, at the mid-height of a tall building, in reducing the wind-induced dynamic responses of the building. The two configurations differ in the pattern of through-building opening on the gap floor, one with opening through the central portion of the floor and the other with opening on the perimeter of the floor around a central core. Wind forces and moments on the building models were measured with a high-frequency force balance from which dynamic building responses were computed. The results show that both configurations of a through-building gap are effective in reducing the across-wind excitation with the one with opening around the perimeter of the floor being significantly more effective. Wind pressures were measured on the building faces with electronic pressure scanners to help understand the generation of wind excitation loading. The data suggest that the through-building gap reduces the fluctuating across-wind forces through a disturbance of the coherence and phase-alignment of vortex excitation.

초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구 (Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan)

  • 박형주;이영재
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.46-54
    • /
    • 2018
  • 국내에서 피난용 엘리베이터가 구비되어 준공된 고층건축물은 서울시 송파구에 위치한 롯데월드타워로 총 19대의 피난용 엘리베이터가 설치되어 있다. 이 건물의 피난계획에 따르면 19대의 피난용 엘리베이터는 비상시 5개의 피난안전층으로부터 피난층(1층)까지 수동 키에 의한 조작으로 셔틀 운행하면서 피난자를 탑승시켜 피난시키도록 규정되어 있다. 따라서 화재 등의 재난발생시 피난용 엘리베이터를 이용한 피난시나리오가 기존의 보행만으로 피난하는 피난시리나리오보다 피난소요시간을 어느 정도 단축할 수 있는가를 분석할 필요가 있다. 롯데월드타워를 대상으로 피난용 엘리베이터에 의한 최적 수송분담률을 40%로 설정한 전관동시 엘리베이터병행 피난시나리오의 피난소요시간이 1 h 2 min으로 산출된 반면, 엘리베이터를 전혀 이용하지 않고 보행만으로 피난하는 전관동시 보행피난시나리오의 피난소요시간은 1 h 29 min으로 산출되었다. 결과적으로 엘리베이터를 병행하여 보행피난하는 경우가 엘리베이터에 의존하지 않은 상태에서 보행으로만 피난하는 경우보다 27 min 정도의 피난소요시간 단축효과가 있는 것으로 도출되었다. 이러한 단축효과를 지속적으로 유지하기 위해서는 엘리베이터를 이용한 피난경로를 이루는 각 부분이 피난이 이루어지는 동안 연기, 화염, 복사열 등의 화재 또는 재난에 기인하는 위험으로부터 피난자를 방호할 수 있는 성능을 갖추고, 엘리베이터 이용 피난자의 상주위치에서 최종피난장소까지의 피난경로가 단절 없이 이어지고 인식이 용이하도록 관리되어야 한다.

도시철도역 시설의 피난에 대한 제도적 한계점 분석과 가이드라인 (Analysis of Institutional Limitations on Evacuation of Urban Railway Station Facilities and Guidelines)

  • 신예경;여옥경
    • 한국방재안전학회논문집
    • /
    • 제15권4호
    • /
    • pp.1-9
    • /
    • 2022
  • 본 연구는 도시철도 지하역의 '피난' 및 '소방'에 관련한 제도적 현황을 분석하여 현행 도시철도 지하역에서의 '피난'에 대한 제도적 한계점을 도출하여 이를 바탕으로 건축공간적 측면에서의 가이드라인을 제안하고자 하였다. 연구의 결과 다음과 같은 점이 도출되었다. 첫째, 유사 기준이 개별법령에 분리 제정되어 기준 파악이 어렵고 서로 이원화되어 있기 때문에, 도시철도에 한정하여 도시철도 이용객의 이동 동선에 따라 머무는 공간을 표준화하여 규정할 필요가 있다. 둘째, 열차 이용을 위해서는 반드시 '티켓팅' 이라는 특수한 절차를 고려해야 하며 대합실과 승강장 사이에 피난안전구역, 피난계단에 대한 규정이 필요하다. 마지막으로 지하 30m이상 깊이의 대심도에서 승강장이 있는 경우, 현행 건축법과 유사한 기준에 따라 피난층을 설치하도록 할 필요가 있다.

경호경비계획을 위한 사무용 고층건축물의 피난안전성평가에 관한 연구 (A Study on Escape Safety Assessment of High-Rise Office Buildings for Security Plans)

  • 박남권;이영주;윤명오
    • 시큐리티연구
    • /
    • 제28호
    • /
    • pp.57-77
    • /
    • 2011
  • 최근 국내외적으로 고층건축물에서 화재, 테러 등의 재난에 의한 연소의 확대로 인하여 재산 및 인명피해가 증가하고 있는 추세이다. 본 연구는 고층건축물에 대한 안전대책의 일환으로 고층사무용건축물에서 재실자의 피난행동예측 및 피난안전성평가를 위해 각각의 시나리오를 설정하여 피난시뮬레이션을 실행하였고, 그 결과데이터를 토대로 피난안전성을 평가하였다. 본 연구를 통해 얻은 결과 및 제안사항은 다음과 같이 요약할 수 있다. 첫째, 현재 경호경비분야에서 고층건축물 및 다중이용시설에 관한 연구는 질적인 연구에 그치고 있는 실정이며, 고층건축물에 대한 경호경비계획에서 심층 분석하고 다각도로 대비함으로서 구체적 실질적 체계적 합리적인 종합안전대책이 마련되어야 위기상황 발생시 피해를 최소화할 수 있다고 판단된다. 둘째, 고층건축물에 대한 경호경비계획에서 피난구획의 설정은 비상시 피난에 있어 영향을 미치는 요인으로 확인이 되었다. 셋째, 고층건축물에 대한 경호경비계획에서 복수 층의 동시 피난 상황을 고려하여, 층별 피난출구의 설정으로 전체 피난완료시간의 단축이 가능함이 확인되었다.

  • PDF