• 제목/요약/키워드: Refrigerator cycle

검색결과 102건 처리시간 0.022초

급속분리커플링으로 연결된 에어컨의 운전성능에 관한 실험적 연구 (A Study on Performance of Air-condition Linked by Quick Disconnect Coupling)

  • 조수;이수열;성욱주;박희문;심경종;김우승
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.551-556
    • /
    • 2008
  • This study analyzed operation characteristics of air-condition piping is made by quick disconnect coupling. Air-conditioning consists of central compressor 3HP capacity and R22 refrigerant. We experimented with two operation cycles of air-condition under the same environment; one is with quick disconnect coupling. The other is without quick disconnect coupling. As a result, we can observe whether the condensation temperature of former increased by about 3-5. Furthermore, COP decreased by about 10%.

  • PDF

전자제품 판매매출액 시계열의 계절 조정과 수요예측에 관한 연구 (A Study on the Seasonal Adjustment of Time Series and Demand Forecasting for Electronic Product Sales)

  • 서명율;이종태
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제3권1호
    • /
    • pp.13-40
    • /
    • 2003
  • The seasonal adjustment is an essential process in analyzing the time series of economy and business. One of the powerful adjustment methods is X11-ARIMA Model which is popularly used in Korea. This method was delivered from Canada. However, this model has been developed to be appropriate for Canadian and American environment. Therefore, we need to review whether the X11-ARIMA Model could be used properly in Korea. In this study, we have applied the method to the annual sales of refrigerator sales in A electronic company. We appreciated the adjustment by result analyzing the time series components such as seasonal component, trend-cycle component, and irregular component, with the proposed method. Additionally, in order to improve the result of seasonal adjusted time series, we suggest the demand forecasting method base on autocorrelation and seasonality with the X11-ARIMA PROC.

  • PDF

보조 흡입구가 장착된 왕복동 압축기의 성능 분석 (Performance of a Reciprocating Compressor Equipped with Auxiliary Port)

  • 이용호;김현진
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

시뮬레이션 기반 수도권 리사이클링 센터 폐냉장고 전처리 공정 개선 (Improvement of the Waste Refrigerator Pre-processing Line in Metropolitan Recycling Center using Simulation)

  • 김도균;강민구;최진영;박기진;공만식
    • 한국시뮬레이션학회논문지
    • /
    • 제22권4호
    • /
    • pp.129-138
    • /
    • 2013
  • 본 논문에서는 수도권 리사이클링 센터 폐냉장고 전처리 공정의 성능 개선 방안에 관하여 연구하였다. 이를 위해 현행 전처리 공정을 기본 작업 단위로 구분하고 공정 별 작업 시간을 측정하여 ARENA를 이용한 모델링 및 성능 분석을 수행하였다. 또한 실무자의 경험과 선진 사례 등에 기반한 3가지 새로운 전처리 공정 대안을 생성한 후 ARENA를 이용한 모델링 및 시뮬레이션을 통해 평가하였다. 최종 선정된 대안은 현행 2-라인 공정을 1-라인으로 전환하고, 냉매를 회수하기 위한 별도의 셀라인을 도입하는 것을 포함한다. 본 연구 결과는 현재 새로운 전처리 공정 라인으로 설치되어 운영되고 있으며, 이전 공정에 비해 사이클 타임과 생산성 향상뿐만 아니라, 공간 활용률 측면에서도 크게 개선된 결과를 보였다.

3 차원 사출성형 해석을 통한 냉장고 플라스틱 서랍 제작용 사출 성형 금형의 형상적응형 냉각수로 설계 (Design of Conformal Cooling Channels for the Mould of a Plastic Drawer of a Refrigerator by Analysis of Three-Dimensional Injection Moulding)

  • 안동규;박민우;박승화;김형수
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1487-1492
    • /
    • 2010
  • 본 논문의 목적은 3 차원 사출성형해석을 통한 냉장고 플라스틱 서랍 제작용 사출성형 금형의 형상적응형 냉각수로 설계이다. 바람직한 형상적응형 냉각수로의 설계를 얻기 위하여 형상적응형 냉각수로의 직경과 위치가 사출성형 특성과 제품의 품질에 미치는 영향을 정량적으로 고찰하였다. 해석결과로부터 제품의 균일 냉각과 변형 최소화가 가능한 최적의 형상적응형 냉각수로의 설계를 도출할 수 있었다. 본 연구에서 제안된 사출성형 금형과 기존의 직선형 냉각수로의 사출성형 금형을 냉각/제품 제작 시간 및 제품 품질 측면에서 비교한 결과, 형상적응형 냉각수로를 가진 사출성형 금형이 제품의 생산성과 품질을 동시에 향상시킬 수 있음을 알 수 있었다.

R-600a 및 R-134a를 공용으로 사용한 소형 냉동사이클의 성능 특성 최적화에 대한 실험적 연구 (An Experimental Study on the Optimization of the Performance Characteristics of a Refrigeration System Using R-600a and R-134a)

  • 장의성;윤원재;정현준;정해원;김용찬
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.268-274
    • /
    • 2010
  • Because both R-134a and R-600a are used as a refrigerant of a household refrigerator in the global market, the home-appliance industry needs an optimized cycle for both refrigerants. The objective of this study is to provide the design guideline on the optimization of a refrigeration system using both refrigerants. For both refrigerants, the performance characteristics of the refrigeration system were tested by varying refrigerant charge amount, capillary tube length, suction diameter and SLHX length. The tested refrigeration system was optimized at the refrigerant charge of 60 g and the capillary tube length of 3600 mm with R-134a, and the refrigerant charge of 34 g and the capillary tube length of 3900 mm with R-600a. The COP increased from 1.63 to 1.68 for R-134a and increased from 1.37 to 1.48 for R-600a, respectively, by applying the suction diameter expansion. In addition, the COP of the R-134a and R-600a system decreased by 2.3~2.4% as the SLHX length decreased by 300 mm.

가정용 전력 모니터링 시스템 및 장치식별 알고리즘 개발 (Development of Home Electrical Power Monitoring System and Device Identification Algorithm)

  • 박성욱;서진수;왕보현
    • 한국지능시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.407-413
    • /
    • 2011
  • 본 연구에서는 가정용 전력 모니터링 시스템을 구현하고 실험가구에 적용하여 평가하였으며, 평가과정에서 확보한 기기별 전력 사용 패턴 정보를 이용하여 자동 기기 식별 알고리즘을 개발하였다. 실험가구에 적용해본 결과, 기기별 전력사용 정보와 월별 예상 사용량 정보가 전력 소비 절감에 도움이 된다는 응답을 얻을 수 있었다. 그리고 시스템을 보다 편리하게 사용하기 위해서는 설치의 편의성과 UI를 개선해야한다는 응답을 얻었다. 본 연구에서는 UI 개선을 위하여 일반냉장고, TV, 전기밥솥, 김치냉장고, 세탁기를 자동으로 식별하는 알고리즘을 구현하였다. 자동 장치 식별 알고리즘은 전력 모니터링 과정에서 수집한 전력 소비 패턴을 관찰하여 Zero-Crossing Rate(ZC), Variation of On State(VO), Slope of On State(SO), Duty Cycle(DC) 등 4가지 특징을 규정하여 이용하였으며, 특징을 적용하는 시간 구간은 기기가 동작하는 시간이 25% 이상이 되는 2시간 길이의 구간을 이용하였다. 제안된 알고리즘은 테스트 set에 동일한 기기를 포함하는 경우 82.1%의 성능을 얻을 수 있었다.

소형 Gifford-McMahon/Joule-Thomson 냉동기에서 열교환기의 최적 조합 (Optimum Size Combination of Heat Exchangers in a Small Gifford-Mchon/ Joule-Thomson Refrigerator)

  • 김영률;이상용;장호명
    • 대한기계학회논문집
    • /
    • 제16권11호
    • /
    • pp.2196-2202
    • /
    • 1992
  • 본 연구에서는 초전도 양자 간섭장치(SQUID, superconductiong quantum inte- rference device)를 냉각시킬 수 있는 정도의 소용량(3.995K에서 0.1W)의 GM/J-T 냉동 기에 대하여 요구되는 냉각용량을 만족시키면서 최대의 성능을 나타낼 수 있는 열교환 기의 면적배분 조건을 구하였다. 즉 냉동 성능을 알고 있는 상용 2단 GM 냉동기와 소형 극저온 냉동기에 널리 사용되는 열교환기로 이루어진 복합적인 GM/J-T 냉동기에 대하여 열교환기 총면적이 주어졌을 때, J-T 회로내의 냉매(헬륨)의 유량과 각 열교환 기 전열 면적의 비를 변수로 최적설계를 행하였다.

대체혼합냉매를 사용하는 Lorentz-Meutzner의 이중 증발기 냉동 시스템의 성능에 관한 연구 (A Study of Lorentz-Meutzner's Two Evaporator Refrigeration System Using Alternative Refrigerant Mixtures)

  • 박영무
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.123-136
    • /
    • 1992
  • A preliminary thermodynamic design model of two-evaporator refrigerator/freezer system is constructed. This system is based on Lorentz-Meutzner cycle using refrigerant mixtures. This model screens alternative refrigerant (R32, R125, R143a, R22, R134a, R152a, R124, R142b, R123) mixtures to select the best performance-giving refrigerant mixtures and its composition for the system. Also, it estimates the effects of cooling temperatures of intercoolers, evaporator's area ratio, cooling load ratio on the performance of the system. The COP of the system ranges from 1.4 to 1.6, which is superior to that of the single evaporator system charged with R12 by 13% to 29%. Among 15 mixtures, R22/R123, R143a/R123, R32/R142b, and R32/R124 (in the order of high COP) are most recommendable. For the case of R22/R123, R22 mass fraction more than 0.5(Load Ratio=1.0) or 0.7(Load Ratio=0.33) is recomended in order to replace R12 without reduction in volumetric capacity when keeping the compressor as the same one. COP has the highest value with X(R22)=0.7 and 0.8, respectively. For the case of R143a/R123, in the similar manner, mass fraction of R143a is more than 0.5 or 0.6 while best performance occurs at X(R143a)=0.8. Higher temperature intercooler is more important for the performance of the system than lower temperature intercooler. The area ratio of evaporators is roughly proportional to load ratio of the evaporators.

  • PDF