• 제목/요약/키워드: Refrigeration conservation

검색결과 79건 처리시간 0.02초

Intelligent big data analysis and computational modelling for the stability response of the NEMS

  • Juncheng Fan;Qinyang Li;Sami Muhsen;H. Elhosiny Ali
    • Computers and Concrete
    • /
    • 제31권2호
    • /
    • pp.139-149
    • /
    • 2023
  • This article investigates the statically analysis regarding the thermal buckling behavior of a nonuniform small-scale nanobeam made of functionally graded material based on classic beam theories along with the nonlocal Eringen elasticity. The material distribution of functionally graded structures is composed of temperature-dependent ceramic and metal phases in axial and thickness directions, called two-dimensional functionally graded (2D-FG). The partial differential (PD) formulations and end conditions are extracted by using to the conservation energy method. The porosity voids are assumed in the nonuniform functionally graded (FG) structure. The thermal loads are in the axial direction of the beam. The extracted nonlocal PD equations are also solved by employing generalized differential quadrature method (GDQM). Last but not least, the information acquired is used to produce miniature sensors, providing a unique perspective on the growth of nanoelectromechanical systems (NEMS).

A Study on the Radiation Effect of the Smoke Movement in Room Fires

  • Jeong, Jin-Yong;Ryou, Hong-Sun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.162-175
    • /
    • 2002
  • To investigate smoke movement with radiation in a room fires, a numerical and experi-mental analysis were performed. In this paper, results from a field model based on a self-developed SMEP (Smoke Movement Estimating Program) were compared with Stockier's ex-periment and the experiments on various sized pool fires in a room with door The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k- $\varepsilon$ turbulence model with buoyancy term. Also it solves the radiation equation using the S-N discrete ordinates method (DOM). The result of the cal-culated smoke temperature considering radiation effect has shown good agreement compared with the experimental data, although there are large discrepancy in the hot smoke layer be-tween the temperature predicted by the SMEP with only convection effect and obtained by the experimental result. This large discrepancy is caused from the radiation effect of $H_2O$ and $CO_2$ gas under smoke productions. Hence the radiation effect under smoke in fire is the point to be specially considered in order to produce more realistic result.

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.

가열패널과 열풍을 이용한 자동차용 도료의 건조특성에 관한 실험적 연구 (An Experimental Study on the Drying Characteristics of Automotive Paint Using Heating Panels and Hot Air)

  • 김성일;박기호
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.828-836
    • /
    • 2010
  • The drying is a process that involves coupled and simultaneous heat and mass transfer. When a wet solid is subjected to thermal drying, two processes occur simultaneously. Drying is classified according to heat transfer characteristics in terms of conduction, convection and radiation. In thermal drying, radiation is easier to control than conduction and convection drying and involves a relatively simple structure. In this study, we measured energy consumption, surface hardness of paint and surface gloss with variation of surface temperature of drying materials and drying time. Drying characteristics and energy consumption between heating panels and hot air heating have been presented. The present study shows that a dryer using heating panels is more effective than a hot air dryer from the viewpoint of energy conservation. The hot air dryer, however, was not optimized and more studies on various parameters related to drying will need to be investigated for definite comparison of drying characteristics of the dryers. The result, even if limited, would present the effective availability of paint drying.

사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성 (Characteristics of Energy Consumption in an Office Building located in Seoul)

  • 박병윤;정광섭
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

차압식 벤튜리콘 유량계에 대한 유동해석 (Numerical analysis of the differential pressure venturi-cone flowmeter)

  • 윤준용;맹주성;이정원
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.714-720
    • /
    • 1998
  • The differential pressure venturi-cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turn-down ratio, low headless, short installation pipe length requirement, and etc. Like other differential pressure flowmeters, the venturi-cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we used Reynolds-averaged Wavier-Stokes equations and k-$\omega$ turbulence model. The equations were fully transformed into the computational domain, the pressure-velocity coupling was made through SIMPLER algorithm, and the equations were discretized using finite analytic solutions of the liberalized equations(Finite Analytic Method). To control the separation phenomenon on the cone surface, we proposed a new shape of cone, and analyzed the flowfield in the new flowmeter system, and found the improvement on the performance of the new cone flowmeter.

  • PDF

실제기체 상태방정식을 이용한 왕복동압축기의 성능해석 (Performance Analysis of a Reciprocating Compressor Using a Real Gas Equation of State)

  • 김정우;김현진;박희용
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.306-315
    • /
    • 1992
  • This paper addresses performance analysis of a reciprocating compressor. A computer simulation model has been developed to predict and estimate the compressor performance. Instead of using ideal gas equations, real gas equations are used in describing the state of gas. The compressor simulation model consists of a cylinder control volume, suction system and discharge system. Conservation laws of mass and energy are applied to the cylinder section only, The suction and discharge system are described by the Helmholtz resonator modeling. Some of input data required for the simulation have been obtained from experiments. These experimentally obtained input data are effective flow area, effective force area and dynamic characteristics of valves. Simulation results of real gas equations have been compared with those of ideal gas equations. It has been found that the simulation with real gas equations yields lower cylinder temperature and heat transfer compared with those of ideal gas equations. Differences in pressure, mass flowrates, valve motions and gas pulsations are found quite small.

  • PDF

AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석 (Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature)

  • 김민지;연상훈;이광호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.51-57
    • /
    • 2018
  • Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

한국형 아파트의 냉난방 에너지에 미치는 제 인자의 영향 (Effects of Various Factors on the Energy Consumption of Korean-Style Apartment Houses)

  • 유호선;현석균;홍희기
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.972-980
    • /
    • 2002
  • This work is aimed at estimating the effects of various factors on the energy consumption of Korean-style apartment houses using TRNSYS. The factors considered here include the nominal size of floor area, type of remodeling, azimuth, sidewall insulation, and window type. Based on some assumptions, an actual apartment house is simplified into a model that is used for thermal load calculations. The simplified model is validated by showing a good agreement with the actual one in the predicted result. Remodeling balconies into unconditioned buffer spaces yields a favorable thermal performance in comparison with the original type regardless of the nominal size. Incorporating balconies into a conditioned indoor space leads to sharp increases in thermal loads, which must be avoided in view of energy conservation as well as structural problem. A quantitative assessment on the azimuthal effect indicates that the heating energy can be saved up to 16% by taking the south or southeast direction. Reduction in the heating load with enhancing the sidewall insulation is gradual, so that a cost-effectiveness analysis may be needed when amending the regulations concerned. Glazing appears to significantly affect the heat transfer through window. A typical case illustrates that the heating load is decreased about 25% by simply adopting triple glazing instead of double glazing.

공조공간에서 수평토출형 에어커튼의 차단 성능 (Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.