광폭 루버 핀이 장착된 핀-관 열교환기의 공기측 전열 성능에 관한 실험적 연구 (An Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fin)

  • 김내현
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.254-262
    • /
    • 2015
  • Heat transfer rate can be increased by increasing the heat transfer area. In this study, wide louver fin-and-tube heat exchangers with $P_t/P_l=1.03$ were tested and compared with louver fin-and-tube heat exchanger with $P_t/P_l=0.6$. Results show that heat transfer capacities of wide louver samples are larger (9.8% at one row, 13.6% at two row and 4.1% at three row) than those of conventional louver samples. Considering the area ratio of 1.78, the increase of heat transfer capacity is rather small, possibly due to the smaller heat transfer coefficient and fin efficiency of the wide louver sample. The j factor of the louver fin was 67% larger at one row, 42% larger at two row and 52% larger at three row. The f factor of the louver fin was 81% larger at one row, 63% larger at two row and 60% larger at three row. The effect of fin pitch on j and f factors are not pronounced and the j factor decreased as the number of tube row increased.

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

GHP 운전시 COV에 의한 정상상태 판별 및 이상검출 방법 연구 (A Study on Steady-State Criterion based on COV and a Fault Detection Method during GHP Operation)

  • 신영기;오세재;정진희
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.705-710
    • /
    • 2011
  • Fault detection has to be proceeded by steady state filtering to get rid of transient effect associated with thermal capacity. Coefficient of variance (COV), ratio of standard deviation devided by moving average, was employed as steady-state filter. Engine speed and refrigerant pressures were selected as parameters representing system dynamics. The filtered values were registered as members of steady-state DB. They were found to show good functional relationship with ambient temperature. The relationship was fitted with a second order polynomial and the distribution bounds of the data around the fitted curve were expressed by visual inspection because of varying average and random data interval. Fault data were compared with the steady-state data obtained during normal operation. The fault data were easily isolated from the fault-free one. To make such isolation reliable, tests to construct good DB should be designed in a systematic way.

성능선도에 의한 다통로 판형열교환기의 간이설계법 (An easy-to-use design procedure for multipass plate heat exchangers based on the performance plots)

  • 유호선;이근휘;방보청
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.250-261
    • /
    • 1999
  • Based on a set of performance plots relating the design variables to the imposed conditions, an easy-to-use and versatile design procedure for chevron-type multipass plate heat exchangers is developed. In order for the present procedure to cover multipass with unequal passes and non-unity ratio of heat capacity rate, each stream number of transfer unit is adopted as the basic design variable instead of the exchanger number of transfer unit. It is found that there exists a unique relation between the stream and exchanger number of transfer units regardless of the chevron angle and the plate length. In addition, for a given value of the pressure drop the heat transfer area per unit mass flow rate can be expressed in terms of the stream number of transfer unit only. These two relationships in the form of simple plots constitute the framework of design. The sample results in comparison with the available data indicate that the present procedure includes the previous ones as a subset, and that every design method is affected essentially by the selection of specific correlations for the heat transfer coefficient and the friction factor.

  • PDF

듀얼 냉동사이클을 이용하는 특수목적 자동차용 에어컨 시스템의 냉방성능에 관한 연구 (Investigation on the Performance of Special Purpose Automotive Air-Conditioning System Using Dual Refrigeration Cycle)

  • 서재형;방유마;이무연
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.213-220
    • /
    • 2016
  • 본 연구의 목적은 열대 지방에서 사용되는 특수목적 자동차용 에어컨 시스템의 냉방성능 특성을 고찰하는 것이다. 이를 위하여 R-134a를 사용하는 듀얼 냉동사이클을 구성하였고 냉매량 및 실내온도를 변화시켜가면서 냉방성능을 비교하였다. 외기온도 $40.0^{\circ}C$에서 듀얼 냉동사이클의 실내 냉각속도 및 압축비(토출압력) 등을 고려하여 최적 냉매량을 1.5kg으로 선정하였다. 실내온도가 증가할수록 냉방부하가 증가하여 $25.0^{\circ}C$에서 $32.5^{\circ}C$로 실내온도를 높일 경우 $15.0^{\circ}C$에 도달하는데 걸리는 시간은 86.5% 증가하였고, $32.5^{\circ}C$에서 $40.0^{\circ}C$로 증가할 경우 38.1% 증가하였다. 또한, 실내온도가 $25.0^{\circ}C$에서 $40.0^{\circ}C$로 증가할수록 냉방용량은 19.1 kW에서 20.5 kW로 7.3% 증가했으나 냉방성능(COP)는 4.67에서 5.1로 7.0%감소하였다.

해수 히트펌프를 이용한 냉동법 담수화시스템 개념설계 (Performance Analysis of Freezing Desalination System using Seawater Heat Pump)

  • 이호생;이승원;윤정인;김현주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.373-378
    • /
    • 2011
  • 해수 히트펌프를 이용한 냉동법 담수화시스템의 개발을 위한 시스템 설계 및 성능 해석을 수행하였다. 해수 히트펌프시스템의 열역학적 모델은 냉동사이클을 이용하였고, 이를 해수 담수화시스템에 적용하였다. 응축기의 유입 해수온도 및 증발기의 얼음 생성 비율에 따른 해수 히트펌프 시스템의 성능을 분석하고, 이에 따른 담수 생산량 및 담수 1kg 생산에 대한 소요 에너지 등 냉동법 담수화 시스템의 성능을 비교 분석하였다. 압축기 소요동력 및 응축기 용량은 응축기로 유입되는 해수온도가 감소함에 따라 감소하였다. 담수 1kg 생산에 따른 소요 에너지는 응축기 유입 해수온도가 $8^{\circ}C$일 때가 $20^{\circ}C$일 때에 비해 약28.9% 감소하였다.

가스흡수식 냉방기용 4성분계 작동매체의 물성 향상 연구 (A Study on Improvement of the Physical Properties of 4 Component Working Fluid in Gas Fired Absorption Chillers)

  • 백영순;오영삼;이용원;박달령;구기갑
    • 공업화학
    • /
    • 제10권3호
    • /
    • pp.400-406
    • /
    • 1999
  • 고효율 가스흡수식 냉방기를 위한 신 작동매체로 기존의 $LiBr-H_2O$ 용액에 $LiNO_3$, LiCl, LiI 성분을 첨가하여 4성분 용액을 제조하였다. 본 연구를 통하여 제조된 4성분계의 작동매체에 대한 용해도와 증기압을 측정하여 기존의 $LiBr-H_2O$계와 비교 분석하였으며, 이들에 대한 최적혼합 몰비를 각각 구하였다. 용해도 측면에서 $LiBr-LiNO_3-LiCl$계는 5:1:1~2, $LiBr-LiNO_3-LiCl$계는 5:1:1, LiBr-LiI-LiCl계의 경우 5:1:0.5~1로 나타났다. 한편 $LiBr-LiNO_3-LiCl-H_2O$계를 제외하고 모두 증기압이 $LiBr-H_2O$계에 비해 높게 나타났다. $LiBr-LiNO_3-LiCl-H_2O$계를 이용한 흡수성능 실험시 $LiBr-H_2O$계 보다 우수한 특성을 지녔다.

  • PDF

녹차 및 천연산물로부터 장염 비브리오균(Vibrio. parahaemolyticus)의 제어를 위한 고추장의 개발 (Development of GOCHUJANG for Controlling V. parahaemolyticus with Green Tea and Natural Products)

  • 김종덕;김민용;정성주;서효진;김은옥;이세영
    • 생명과학회지
    • /
    • 제15권5호
    • /
    • pp.783-789
    • /
    • 2005
  • V. pnrahaemolyticus를 저해하는 천연산물 조합 추출물을 이용하여 고추장을 제조하였다. 각각의 천연산물 및 천연산물 조합 추출물의 항산화력 크기는 ORP system value를 이용하여 측정하였고, 천연산물 조합 추출물을 이용하여 제조한 고추장을 disk 법으로 IZD (Inhibition zone divided by diameter of disk)를 측정하여 제어의 정도를 비교하였다. 그 결과 한 가지 천연산물에서는 황백, 오미자, 녹차가 높게 나타났고, 이들 천연산물을 조합했을 때도 항산화력이 높게 나타나 기능성 고추장을 제조할 수 있을 것이라 판단하였다. 그리고 항산화력이 높게 측정된 황백, 오미자, 녹차 그리고 황금의 A조합과 A조합에 오가피를 첨가한 B조합의 IZD를 측정하였을 때 각각 $1.57\pm0.0051$$1.56\pm0.0071$로 제어력이 뛰어나 A조합과 B조합의 천연산물의 추출물을 이용하여 고추장을 제조하였다 고추장을 제조하였을 때 A조합(IZD: $1076\pm0.0103$)보다 B조합(IZD: $1079\pm0.0103$)이 좋게 나타났고, 이 고추장으로 식초를 첨가하여 초고추장을 제조하였을 때도 A조합(IZD: $2.15\pm0.0071$)보다 B조합(IZD: $2.44\pm0.0086$)이 뛰 어난 제어력을 보였다 여기에 chitosan, 마늘, 메주의 첨가는 유의성 있는 제어력을 나타내지 못하였다.

열펌프를 이용한 벼의 저온건조성능평가 (Performance Evaluation of Rough Rice Low Temperature Drying Using Heat Pump)

  • 김훈;한재웅
    • 산업식품공학
    • /
    • 제13권4호
    • /
    • pp.308-313
    • /
    • 2009
  • 국내 벼 건조기간의 기상조건에 적합한 열펌프를 설계, 제작하여 기본 성능을 측정하고, 건조온도 20-50${^{\circ}C}$ 범위에서 벼 건조실험을 통하여 건조특성 및 소요에너지를 분석하였다. 열펌프는 건압축 냉동 사이클에서 냉동효과는 173.8 kJ/kg이었으며, 냉매순환량은 49.6 kg/hr이었다. 따라서, 성능계수는 5.5로 표준냉동사이클에서 냉매 R-22의 성능계수 4.0에 비해 높은 값을 나타내었으며, 목표 건조공기의 온도 30${^{\circ}C}$ 및 상대습도 40%에 도달하는 시간은 6분 및 7분으로 만족할 만한 수준이었다. 건조온도와 곡온과의 온도차이는 건조온도 21.9${^{\circ}C}$에서는 약 1.5${^{\circ}C}$, 건조온도 48.7${^{\circ}C}$에서는 약 8.5${^{\circ}C}$로서, 건조실에서 상승한 곡온은 템퍼링실에서 충분한 냉각이 이루어지는 것으로 판단되었다. 건조온도 21.9, 30.7 38.8 및 48.7${^{\circ}C}$에서 건조속도는 0.29, 0.61, 0.85 및 1.25%/hr로 나타나 상용건조기와 유사한 수준이었다. 건조온도 21.9${^{\circ}C}$에서 소요에너지는 325 kJ/kg, 건조온도 30.7, 38.8 및 48.7${^{\circ}C}$에서는 667, 692 및 776 kJ/kg로 나타나 외기조건에 따라 건조소요에너지의 차이가 발생했지만, 화석연료를 사용하는 상용 화력건조기의 벼 건조소요에너지 4,000-5,000 kJ/kg에 비해 평균 86% 절감되는 것으로 나타났다.