• Title/Summary/Keyword: Refrigeration and air conditioning

Search Result 3,408, Processing Time 0.024 seconds

A Survey on the Indoor Temperature and Power Consumption of Domestic Refrigerator (가정용 냉장고의 고내온도 및 전력소비 실태조사)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.357-366
    • /
    • 2018
  • In this study, if the set temperature of the refrigerator differs from the set temperature of the refrigerator, the temperature distribution of food in the refrigerator is estimated by measuring the temperature in the refrigerator and in the refrigerator room. In addition, based on the set temperature of the refrigerator and the freezer, the temperature range of the heat is large and the time required to recover to the set temperature is to be determined. And the optimal setting temperature for home refrigerators is to be shown by measuring the amount of power consumed to recover to the set temperature. As a result, the conditions in which the temperature in the freezer realized $-18^{\circ}C$ were only appropriate in case 3, Case 6, Case 8, and Case 9 when the set temperature in the refrigerator was lower than that in the freezer. Under these conditions, the minimum temperature in the refrigerator was $-1.1^{\circ}C$, Case 6 was $-1.5^{\circ}C$, Case 8 was $-1.1^{\circ}C$ and Case 9 was $-0.8^{\circ}C$, respectively. Also, the total power consumption during the 10 hours operation time of each case was greater than the setting temperature of the freezer and the refrigerator except case 4, since case 4 started operation around 13:30 in the morning.

A study on the needs for the cool motorcycle helmet and the factors affecting the purchasing intention (오토바이용 쿨 헬멧의 필요성과 구매요인에 관한 조사연구)

  • Seong, Deokhyun;Kim, Jongsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8386-8393
    • /
    • 2015
  • This study is to investigate the needs for the cool motorcycle helmet and the factors affecting the purchasing intention of cool helmet. The convenient sampling from motorcycle clubs were conducted during 5/20/2014~5/28/2014 on Google DAX. As a result, 197 participants were surveyed. The main reasons of sensing unpleasant feeling wearing helmet were identified as 'hot and uncomfortable feeling' and 'it ruins hair style'. The mean score expressed in terms of five point scale showed that the needs for cool helmet was 3.9 and the purchasing intention of cool helmet was 3.6, respectively. The significant factors influencing the purchasing intention of cool helmet were identified as 'the needs for cool helmet' (odds ratio=6.52) and 'extra paying intention for cool helmet' (odds ratio=1.77). The main reasons of sensing unpleasant feeling wearing helmet were similar to the previous research. However, we can expect that the initial target market for cool helmet would be the low end (less than \40,000 of extra paying intention) or the high end (more than \100,000 of extra paying intention). The main contribution of this study is dealing with the topics related to the purchasing intention of the cool helmet.

Control of torsional vibration for propulsion shafting with delayed engine acceleration by optimum design of a viscous-spring damper (점성-스프링 댐퍼 최적화 설계를 이용한 엔진 증속지연 특성을 갖는 추진축계 비틀림진동 제어)

  • Kim, Yang-Gon;Hwang, Sang-Jae;Kim, Young-Hwan;Kim, Sang-Won;Cho, Kwon-Hae;Kim, Ue-Kan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.580-586
    • /
    • 2016
  • The ultra-long stroke engine was developed to generate greater power at lower speeds than previous designs to enhance the propulsion efficiency. The torsional exciting force, on the other hand, was increased significantly. Therefore, it is possible to control the torsional vibration of its shaft system equipped with the fuel efficient ultra-long stroke engine by adopting a damper although the torsional vibration could be controlled adequately by applying tuning and turning wheels on the engine previously. In this paper, the dynamic characteristics of a viscous-spring damper used to control the torsional vibration of the corresponding shaft system are reviewed and then examined to determine what vibration characteristics might be used to optimize the viscous-spring damper. In some cases, operators of eco-ships have recently experienced the problem of delayed RPM acceleration. It has been suggested that the proper measures for controlling the torsional vibration in the shaft system should involve adjusting the design parameters of its damper determined by the optimum damper design theory to avoid the fatigue damage of shafts.

Evaporating heat transfer characteristics of Aluminum-brass tube for seawater cooling system using R-134a (해수냉각시스템용 Aluminium Brass Tube의 R-134a 증발열전달 특성)

  • Kang, In-Ho;Seol, Sung-Hoon;Yoon, Jung-In;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • Most fishing vessels use an ice cooling system to manage and store captured fish. However, it is difficult to maintain an adequate temperature and salt concentration as well as operating time limitations in ice cooling systems. The purpose of this study is to investigate the heat transfer characteristics of flooded-type evaporators for a seawater cooling system to maintain proper seawater temperature in a fish tank. Experiments were conducted to investigate the heat transfer characteristics by changing the seawater temperature, flow rate, and saturation temperature of the refrigerant. It was confirmed that the heat transfer coefficient of an aluminum-brass tube was approximately 10% higher than that of a copper-nickel tube at the same heat flux. Furthermore, it was confirmed that applying the aluminum-brass tube to the heat transfer tube of a seawater heat exchanger was effective in terms of heat transfer. A comparison of the overall heat transfer coefficient of a single-tube heat exchanger and the flooded-type multi-tube heat exchanger for an 18-kW cooling system showed that the heat transfer coefficient of the single-tube heat exchanger was 25% higher under the same conditions. These results are considered to be important data for designing a flooded-type multi-tube heat exchanger.

A Study on the Effects of Design Parameters of Vertical Ground Heat Exchanger on the Borehole Thermal Resistance (수직밀패형 지중열교환기의 설계인자가 보어홀 전열저항에 미치는 영향에 관한 연구)

  • Chang, Keun Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.128-135
    • /
    • 2018
  • Currently, vertical closed ground heat exchangers are the most widely utilized geothermal heat pump systems and the major influencing parameters on the performance of ground heat exchangers are the ground thermal conductivity(k) and borehole thermal resistance($R_b$). In this study, the borehole thermal resistance was calculated from the in-situ thermal response test data and the individual effects of design parameters (flow rate, number of pipe, grout composition) on the borehole thermal resistance were analyzed. The grout thermal resistance was also compared with the correlations in the literatures. The borehole thermal resistance of the investigated ground heat exchanger results in 0.1303 W/m.K and the grout thermal resistance (66.6% of borehole thermal resistance) is the most influencing parameter on borehole heat transfer compared to the other design parameters (pipe thermal resistance, 31.5% and convective thermal resistance, 1.9%). In addition, increasing the thermal conductivity of grout by adding silica sand to Bentonite is more effective than the other design improvements, such as an increase in circulating flowrate or number of tubes on enhancing borehole heat transfer.

Evaluation of Characteristics of G-class Cement for Geothermal Well Cementing (지열 발전정 시멘팅을 위한 G-class 시멘트 특성 평가에 관한 연구)

  • Won, Jongmuk;Jeon, Jongug;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.29-38
    • /
    • 2013
  • The G-class cement is commonly used in practice for geothermal well cementing in order to protect a steel casing that is designed to transport hot water/steam from deep subsurface to ground surface during operating a geothermal power plant. In order to maintain optimal performance of geothermal wells, physical properties of the cementing material should be satisfactory. In this paper, relevant factors (i.e., groutability, uniaxial compression strength, thermal conductivity and free fluid content) of the G-class cement were experimentally examined with consideration of various water-cement (w/c) ratios. Important findings through the experiments herein are as follows. (1) Groutability of the G-class cement increases by adding a small dose of retarder. (2) There would be a structural defect caused when the w/c ratio is kept higher in order to secure groutability. (3) Thermal conductivity of the G-class cement is small enough to prevent heat loss from hot steam or water to the outer ground formation during generating electricity. (4) The G-class cement does not form free water channel in cementing a geothermal well. (5) The Phenolphthalein indicator is applicable to the distinction of the G-class cement from the drilling mud.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.

Studies on the major nutritional components of commercial dried lavers (Porphyra yezoensis) cultivated in Korea (시판 건조김의 주요 영양성분)

  • Kim, Ki-Woong;Hwang, Jae-Ho;Oh, Myung-Joo;Kim, Min-Yong;Choi, Myeong-Rak;Park, Wook-Min
    • Food Science and Preservation
    • /
    • v.21 no.5
    • /
    • pp.702-709
    • /
    • 2014
  • This study was conducted to provide basic date on the proximate composition and amino acid, fatty acid, sugar, and mineral contents of commercial dried lavers cultivated in Korea (in Seocheon, Wando, Goheung and Busan). The moisture, crude ash, crude fat, crude protein, and carbohydrate content ranges of the dried lavers were 5.67~7.43%, 8.01~8.95%, 1.54~2.25%, 37.77~39.98%, and 43.83~46.24%, respectively. The total amino acid, free amino acid, and essential amino acid concentrations were highest (25,982.15 mg/100 g, 4,545.44 mg/100 g, and 9,048.28 mg/100 g) in the dried lavers cultivated from Wando. The compositions of the fatty acids in four dried lavers were 16.30~22.15% saturated fatty acids, 6.04~7.73% monounsaturated fatty acids, and 70.33~76.03% polyunsaturated fatty acids. The sugar contents per 100 g of dried lavers were 3,678.84~4,052.52 mg of galactose, 2,112.30~2,473.86 mg of fructose, 1,103.74~1,648.39 mg of mannose, 361.67~590.21 mg of glucose, 8.63~10.38 mg of ribose, and 21.43~48.32 mg of xylose. The mineral concentrations in the dried lavers cultivated from Wando and Busan were low (Cu < Mn < Zn < Fe < Ca < Mg < Na < K), as were those in the dried lavers cultivated from Seocheon and Goheung (Cu < Mn < Zn < Fe < Mg < Ca < Na < K).