• Title/Summary/Keyword: Refrigeration Systems

Search Result 500, Processing Time 0.026 seconds

Comparison of System Performances of Hot-gas Bypass and Compressor Variable Speed Control of Water Coolers for Machine Tools (핫가스 바이패스 및 압축기 가변속 제어에 의한 공작기계용 수냉각기의 성능 비교)

  • Jeong, Seok-Kwon;Lee, Dan-Bi;Yoon, Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a cooler system to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the water cooler system. In this paper, comparisons of system performances according to the control schemes in a cooler for machine tools were conducted in detail. Each proportional-integral feedback controller for the two different control systems is designed. The system performances, especially the temperature control accuracy and coefficient of performance which is a criterion of energy saving, were mainly analyzed through various experiments using 1RT water cooler system with different two types of control scheme. These evaluations will provide useful information to choose suitable water cooler system for the engineers who design controllers of the cooler system for machine tools.

A Study of Simulation on the Refrigerated Warehouse System Based on the Cold Energy of Lng Using the Pro-Ii Simulator (LNG 냉열을 이용한 냉장·냉동 창고 모사에 관한 연구)

  • HAN, DANBEE;KIM, YOONJI;YEOM, KYUIN;SHIN, JAERIN;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.401-406
    • /
    • 2017
  • When Liquified Natural Gas (LNG) is vaporized into NG for industrial and household usage, tremendous cold energy was transferred from LNG to seawater during phase-changing process. This heat exchanger loop is not only a waste of huge cold energy, but will cause thermal pollution to the coastal fishery area also when cold water was re-injected into the sea. In this study, an innovation design has been performed to reclaim the cold energy for -35 to $62^{\circ}C$ refrigerated warehouse. Conventionally, this was done by installing mechanical refrigeration systems, necessitating tremendous electrical power to drive temperature. A closed loop LNG heat exchangers in series was designed to replace the mechanical or vapor-compression refrigeration cycle by process simulator. The process simulation software of PRO II with provision has been used to simulate this process for various conditions, what to effect on cold energy and used energy for re-liquefaction and evaporation process. In addition, through analysis the effect of the change of LNG supply pressure on sensible and latent heat, optimum operational conditions was suggested for LNG cold energy warehouse.

A Study on Worker Exposure to Trichlorethylene and Emission Factor for Degreasers in Plating Plants (중소기업 도금공정에서의 트리클로로에틸렌 폭로와 발산량에 관한 연구)

  • Lee, Keoung Hee;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.3-13
    • /
    • 1993
  • This study was conducted at seven degreasing processes in plating plants located in Seoul, Incheon, Ansan, and Taejeon areas from July 21 to august 27, 1992. This study was performed to assess the TWA exposures to trichloroethylene (TCE) and evaluate factors affecting TCE concentrations in degreasing process. Two-Point Eddy Diffusional Model suggested by Wadden et al. was employed to calculalte emission factors according to degreaser type. Results are summarized as follows. 1. The TWA exposures of the degreasing operators ranged from 1.4 ppm to 123 ppm, and those of three plants out of seven were exceeding 50 ppm of both the Korean and U.S. OSHA standards. Degreasing assistant of Plant B, was exposed to 59 ppm. 2. The average concentrations at the distance 0, 1.5, 3.0 m from the degreasers were 1.014, 24, and 18 ppm, respectively, and showed a signifficant difference by distance (p<0.01). 3. The emission of TCE was reduced by installing local exhaust systems, condensers, and refrigeration lines at the degreasers (p<0.01). 4. The major factors related to exposure of operators were workload (r=.9621. p<0.01) and dimensions of degreansing room(r=-.8667, p<0.05). 5. If the air in degreasing room is mixed violently by other factors in addition to diffusion, the emission factors can not be evaluated because the important hypothesis of the Two-Point Eddy Diffusional Model can not be accepted. 6. The ultrasonic degreaser without the local exhaust ststem, condenser, and refrigeration lines emitted TCE three times greater than the ultrasonic degreaser with condenser and refrigeration 1ines only.

  • PDF

Effects of the electronic expansion valve and variable velocity compressor on the performance of a refrigeration system

  • Lago, Taynara G.S.;Ismail, Kamal A.R.;Nobrega, Claudia R.E.S.;Moura, Luiz F.M.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.1-19
    • /
    • 2020
  • Energy consumption of air-conditioning and refrigeration systems is responsible for about 25 to 30% of the energy demand especially in hot seasons. This equipment is mostly electricity dependent and their use in principle affects negatively the environment. Enhancing the energy efficiency of the existing equipment is important as one of the measures to reduce environment impacts. This paper reports the results of an experimental study to evaluate the impacts of the use electronic expansion valve and variable velocity compressor on the performance of vapor compression refrigeration system. The experimental rig is composed of two independent circuits one for the vapor compression system and the other is the secondary fluid system. The vapor compression system is composed of a forced air condenser unit, evaporator, hermetic compressor and expansion elements, while the secondary system has a pump for circulating the secondary fluid, and an air conditioning heat exchanger. The manufacturer's data was used to determine the optimal points of operation of the system and consequently tests were done to evaluate the influence of variation of the compressor velocity and the opening of the expansion device on the performance of the refrigeration system. A fuzzy logic model was developed to control the rotational velocity of the compressor and the thermal load. Fuzzy control model was made in LabVIEW software with the objective of improving the system performance, stability and energy saving. The results showed that the use of fuzzy logic as a form of control strategy resulted in a better energy efficiency.

A Basic Study on Selection of Refrigeration Oils for R-134a Refrigerant (R-134a 냉매용 냉동기유 선정을 위한 기초 연구)

  • Na, B.C.;An, Y.J.;Han, D.C.;Chun, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.439-452
    • /
    • 1994
  • One of the chlorofluorocarbon compounds. R-12 deplete atmospheric ozone. It leads to international agreement to reduce CFC production. R-134a has similar thermodynamic properties to CFC-12. It has zero ODP(Ozone Depletion Potential). This Paper focuses on the lubricating oils for using with R-134a PAGs(Polyalkylene Glycol's) and esters are primary lubricants that are now being tested for use with R-134a Because of extreme polarity of R-134a. there are many problems in the selection of lubricating oil. This investigation analyzes compressor working conditions and calculates wear parts friction for simulation testing. Miscibility and material compatibility is proved by sealed glass tests. Friction was tested on the closed type pin on disk wear tester. This equipment simulates actual refrigerating compressor. Environment controlled test made more reliable result than field test Conventional oils(mineral oils, Alkylbenzene, PAO(Polyalpha Olefin) are immiscible with R-134a. PAGs and ester oils are miscible with R-134a. Friction coefficient is similar to conventional system(mineral oil/R-12 systems) at operating condition. At start & stop condition, PAGs/R-134a system has high friction coefficient. It provide reliable result on the lubricity, miscibility, material compatibility of R-134a with these new lubricants. It suggests proper selection of refrigeration oil that may improve compressor durability of performance.

  • PDF

Research on Thermal Performance by Different Fins in a Solar Air Heater (태양열 공기난방기에서 핀의 형상에 따른 열전달 성능 평가)

  • Choi, Hwi-Ung;Hong, Boo-Pyo;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.85-91
    • /
    • 2013
  • It is essential to reduce the amount of fossil fuel because facing with the natural problem such as a global warming. To achieve this goal, many of interests in the use of renewable energy is growing. Especially, as one of these renewable energy systems, a solar air heater invention has been conducted for enhancing the efficiency of solar air heater. According to this trend, scale-down sized experiment apparatus was constructed and performed for searching a proper fin and confirming the heat transfer performance by fin shape on constant heat condition to enhance efficiency of solar air heater. In this experiment, heat gain, convection heat transfer coefficient, number of transfer units, Nusselt number, Reynold's number, friction factor, performance factor were investigated in order to evaluate the thermal characteristics based on the real data obtained. By comparison with the each fin performance, a zigzag shape keeping a right angle to the plate had the highest value among them.

An Experimental Study of the Performance Characteristics on Multiple-tube Heat Exchanger in the Vapor Compression Refrigeration System (증기압축식 냉동장치에서 다증관 열교환기의 성능특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • This paper is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this paper are basic data to design the optimum tripple-tube heat exchanger.

Experimental Study on Heat Transfer and Pressure Drop Characteristics for Single-Phase Flow in Plate and Shell Heat Exchangers. (Plate and Shell 열교환기의 단상유동 열전달 및 압력강하 특성에 관한 실험적 연구)

  • 서무교;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.422-429
    • /
    • 2000
  • Plate and shell heat exchanger(P&SHE) is widely applied as evaporators or condensers in the refrigeration and air conditioning systems for their high efficiency and compactness. In order to set up the database for the design of the P&SHE, heat transfer and pressure drop characteristics for single phase flow of water in a plate & shell heat exchanger are experimentally investigated in this study. Single phase heat transfer coefficients were measured for turbulent water flow in a plate and shell heat exchangers by Wilson plot method. The shell side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a plate side were obtained by Wilson plot method. Single-phase heat transfer correlations based on projected heat transfer area and friction factor correlations have been proposed for single phase flow in a plate and shell heat exchanger.

  • PDF

冷凍配管 技術基準 解說

  • 최인주
    • Journal of the KSME
    • /
    • v.19 no.4
    • /
    • pp.326-331
    • /
    • 1979
  • 압력배관에 대한 미국의 국가규준으로는 다음과 같은 것이 있다. Section 1. Power Piping ANSI B31.1 Section 2. Fuol Gas Piping ANSI B31.2 Section 3. Petroleum Refinery Piping ANSI B31.3 Section 4. Liquid Potroleum Transportation Piping ANSI B31.4 5. Section Refrigeration Piping ANSI 31.5 Section 6. Chemical Plant Piping ANSI B31.6 Section 7. Nuclear Power Piping ANSI B31.7 Section 8. Gas Transmission and Distribution Piping Systems ANSI B31.8 이중에서 Power Piping ANSI B31.1은 1977년도에 공진청에서 제정한 "압력배관 기술 기준 (1) "의 기본이 되고 있다. 금반의 냉동배관 기술기준 제정에 있어서도 이것이 압력배관의 범주내에 포함되는 것이기 때문에 기준의 통일성을 기하기 위하여서는 압력 배관기술기준(1)에 준하여 ANSI B31.5 Refrigeration Piping을 기본으로 하여야 할 것으로 고려하였다. 현재 각국의 압력 배관에 대한 기술기준은 그 형식은 여하간에 기본적으로는 ANSI B31. 시리즈에 따르고 있고 또 이 규준이 국제적으로 인정 널리 시행되고 있으므로 본 냉동배관 기술기준도 ANSI B31.5에 따라 제정하는 것이 타당성이 있는 것으로 고려하였다.

  • PDF

The Frost and Defrost Performances of Fin-and-Tube Exchangers with Different Surface Characteristics (표면특성이 다른 두 핀-관 열교환기의 착상 및 제상 성능)

  • 신종민;최봉준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.525-531
    • /
    • 2002
  • The effects of different surface hydrophilicity on frosting and defrosting characteristic were experimentally investigated. Mass of frost and water hold-up was measured. Results showed that no significant difference in the frost mass was found between the two different surfaces while the water hold-up of heat exchanger court be reduced by the enhancement of surface hydrophilicity. Also, the defrosting efficiency m hydrophilic surface was improved by 76%. It was expected that hydrophilic heat exchanger could provide the improvements in both thermal-hydraulic performances and system reliability during frost/defrost operating in refrigeration systems.