• 제목/요약/키워드: Refrigeration Performance

검색결과 1,610건 처리시간 0.023초

대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon Refrigerants)

  • 노건상
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.

운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성 (Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions)

  • 백승문;손창효;허정호;최인수;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1021-1026
    • /
    • 2014
  • 본 논문에서는 hot-gas를 이용한 다양한 바이패스 제어 방식 중에서 증발기 흡입부 방식에 대해 각각의 성능에 영향을 미치는 외기온도, 출수온도, 과열 및 과냉도 등에 대해서 알아보았다. 그 주요 결과를 요약하면 다음과 같다. 우선, 증발기 흡입부로 hot-gas를 바이패스 하였을 경우에 냉동장치의 성능은 외기온도, 출수온도, 과열 및 과냉도 등에 영향을 받는 것을 알 수 있었다. 따라서 이러한 변수에 대한 최적화를 통해 본 냉동장치의 기초 설계 자료를 제공할 수 있다. 그리고 증발기 흡입부 hot-gas 바이패스 방식의 운전특성을 고찰하여 본 논문에서 제안하는 냉동장치에 대한 적용 가능성을 확인할 수 있었다.

부하변화에 따른 hot-gas 바이패스 방식별 성능 비교 (Performance Comparison of Hot-gas Bypass Types with the Variation of Refrigeration Load)

  • 백승문;윤정인;손창효;허정호
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.48-54
    • /
    • 2014
  • In this paper, three refrigeration systems bypassing hot-gas to compressor outlet, compressor and condenser outlet and evaporator inlet are theoretically compared to offer basic design data for performance depending on cooling load using a HYSYS program. The main results are summarized as follows : First, the COP of third system is the highest. Next, the COP of second system is higher than first one. And, the temperature of compressor inlet of third system is constant for all cooling load. Compared to first and second system, the compressor inlet temperature of the first system is higher than second one for all cooling loads. From the above results, third system, which is bypassing hot-gas to evaporator inlet, is more advantageous when considering the precise temperature control and excellent performance of oil and water cooler of industrial machine.

A Study on The Counter-Flow Cooling Tower Performance Anaysis and Experiments

  • Seo, Moo-Gyo;Kim, Young-Soo;Kim, Eun-Pil;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.50-57
    • /
    • 2001
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air and water-air flow rate. In this stud${\gamma}$, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from 6.8$m^3/hr{\cdot}m^2$ to 159$m^3/hr{\cdot}m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from 22${\circ}C$ to 29${\circ}C$.

  • PDF

외란을 고려한 냉동시스템의 최적 PI 제어기 설계 (Optimal PI Controller Design for Refrigeration System Considering Disturbance)

  • 정석권;홍기학
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.85-93
    • /
    • 2013
  • The proportional plus integral(PI) feedback control manner has been used in many general industrial fields such as refrigeration system because of its simple design process and favorable control performance. This paper deals with optimized PI controller design of the refrigeration system based on evaluation functions such as integrated absolute error(IAE). The suggested optimal PI gains can be easily calculated by a simple program and the optimal controllability satisfying the evaluation function can be assured. Furthermore, at the initial step of controller design, the suggested optimal gain is able to reflect some noise disturbances caused by an inverter which drives variable speed compressors. The validity of the suggested optimal gain is investigated by some simulations and experiments to verify its efficiency. From the results of comparing control performance between the optimal PI controller based on the evaluation function and the PI controller designed by the Matlab tuner which was known as the most popular gain tuner, the optimal PI controller showed more desirable control performance especially in transient responses.

열전소자 냉각 자켓의 설계인자가 열전냉각 시스템의 성능에 미치는 효과에 대한 실험적 연구 (An Experimental Study on the Effects of the Cooling Jacket Design Parameters on the Performance of Thermoelectric Cooling System)

  • 이정은;박상희;김경진;김동주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2079-2084
    • /
    • 2007
  • A small-scale thermoelectric cooling system was built in an effort to enhance the performance of the refrigeration system by utilizing the water-cooled jacket which was attached on the hot side of the thermoelectric module. Considered design parameters for the water-cooled jacket included the geometry of the flow passage inside the jacket and the flow rate of cooling water. The higher flow rate of cooling water in the jacket resulted in a better performance of the refrigeration system. The introduction of geometrical complexity of the cooling water flow passage to the cooling jacket also showed significant improvement on the performance of the thermoelectric refrigeration system such as the cooling capacity and the COP of the refrigeration system.

  • PDF

2상류이젝터를 이용하는 $CO_{2}$ 냉동사이클의 성능해석 (Performance analysis of $CO_{2}$ refrigeration cycle with two-phase ejector)

  • 이윤환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.946-952
    • /
    • 2005
  • The $CO_{2}$ refrigeration cycle is expected to reduce the compressor work and increase the COP by applying two-phase ejector as a device for the recovery of dissipated expansion energy. In this study, the performance of the cycle was simulated and effects of the ejector shapes on the performance of the $CO_{2}$ refrigeration cycle were investigated. The following results were obtained through the cycle simulation. The COP of the $CO_{2}$ refrigeration cycle with two-phase ejector flow which expansion is occured in the isentropic manner is increased by a maximum of 24 $\%$ than the basic cycle with expansion valve If the velocity nonequilibrium in the mixing process is assumed the COP of the cycle is increased with the increase of the length and the decrease of the section area of the mixing tube. The best cycle performance is obtained when the divergent angle of diffuser is 7.

An Experimental Study on the Performance of $CO_2$ Air-conditioning Cycle Equipped with an Ejector

  • Kim, Mo-Se;Lee, Jae-Seung;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권3호
    • /
    • pp.100-106
    • /
    • 2009
  • As an effort to prevent environmental problems caused by ozone depletion and global warming, alternative refrigerants are being developed, and one of the candidates is carbon dioxide. To overcome slightly low efficiency of $CO_2$ refrigeration system, air-conditioning cycle using an ejector was suggested. Ejector compensates throttling loss in an expansion device by reducing compression work. In this study, the ejector refrigeration cycle using $CO_2$ as a refrigerant is investigated to understand the effect of the mixing section diameter and refrigerant charge amount on the performance. If mixing section diameter is too large or too small, either cases show low performance. The optimum refrigerant charge amount which gives the best performance is found for standard operating conditions. The air-conditioning cycle was analyzed for several operating conditions.

Decoupling Control Design for Variable Speed Refrigeration System of a Ship

  • Hua, Li;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권7호
    • /
    • pp.808-815
    • /
    • 2006
  • In this paper, we suggest decoupling control method based on general PI control law to control variable speed refrigeration system of the ship effectively. In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. Thus, we propose decoupling model to eliminate the interfering loop between capacity and superheat at first. Next, we design PI controller to control capacity and superheat independently and simultaneously. Finally the control performance was investigated through some experiments. The experimental results show that the PI control design can obtain good control performance under the adjustable control reference and thermal load variation.

이산화탄소를 냉매로 사용하는 오토캐스케이드 냉동기의 성능에 관한 해석 및 실험 (Analysis and Experiment on The Performance of an Autocascade Refrigeration System Using Carbon Dioxide As a Refrigerant)

  • 김성구;김민수
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.411-421
    • /
    • 2001
  • The purpose of this study is to investigate the performance of an autocascade refrigeration system by simulation and experiment using refrigerant mixtures of R744/134a and R744/290 as working fluid. Variations of mass flow rate of refrigerant, compressor work refrigeration capacity and COP with respect to mass fraction of R744/134a and R744/290 mixture were presented under different operating conditions. Performance test has been executed by ASRAE standard. Experimental results show as the composition of R744 in the refrigerant mixture increases, heating and coling capacity are enhanced, but COP trends to decrease. Experimental results are compared with those from the simulation.

  • PDF