• 제목/요약/키워드: Refrigeration Effect

검색결과 849건 처리시간 0.026초

Effect of different concentrations of hypotaurine on melanosis and quality of Pacific white shrimp (Penaeus vannamei) during refrigeration

  • Zhou, Jiaying;Ying, Yubin;Zhou, Yaqi;Li, Gaoshang;Hu, Yaqin
    • Fisheries and Aquatic Sciences
    • /
    • 제25권4호
    • /
    • pp.231-242
    • /
    • 2022
  • Effect of different concentrations of hypotaurine (HTU) on melanosis and quality of shrimps during 10 d storage in ice were studied. During refrigeration, the total plate count and total volatile basic nitrogen of shrimps treated with 20 g/L HTU were the lowest, and the hardness and microstructure were the best. Moreover, the score of melanoses, pH and total bile acid of shrimps treated with 20 g/L HTU were also low. Sensory evaluation showed that HTU treatment could make the shelf life of shrimps 3-4 days longer compared with the control. Based on the above physical and chemical indexes, 20 g/L HTU showed great potential as a safe inhibitor in the treatment of shrimps' melanosis.

경계조건에 따른 가스터빈 블레이드 냉각공기 유량변화 (Effect of Boundary Condition on the Flow Rate of the Internal Coolant in Gas Turbine Blades)

  • 신지영;박병규
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.888-894
    • /
    • 2001
  • Advanced gas turbine engines employ turbine entry temperatures so high that cooling of the turbine blades is essential. The coolant flow introduces losses which need to be minimized, and therefore it is important that the minimum amount of coolant should be used. This work presents the result of the one-dimensional analysis and the effect of the boundary conditions on coolant flow rate in gas turbine blades.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

냉동·공조기 배관내 스케일 자동제거장치의 효과 (Effect of Aotomatic Scale Removal System for Piping in Refrigeration & Air Conditioning System)

  • 김종열
    • 한국응용과학기술학회지
    • /
    • 제34권4호
    • /
    • pp.908-914
    • /
    • 2017
  • 본 연구는 냉동공조용 열교환기 내 스케일 형성으로 열전달 과정에서 열저항으로 작용하여 냉동공조시스템의 냉각성능이 떨어져 이를 해결하기 위해 전기분해 원리를 이용하여 배관 내 스케일을 자동 제거하는 시스템을 개발하여 그 성능을 실험을 통해 확인하고자 한다. 이전까지는 배관 내 스케일을 2~3년에 한번씩 브러시나 분사 노즐에 의해 기계적으로 배관 내를 청소를 하거나 화학약품을 이용하여 세관하였다. 이러한 세관은 시간이 경과하면 또 관이 오염되어 전열성능이 떨어지고 냉각장치의 운전을 정지하여 반복해야 하는 여러 가지 문제점을 안고 있었다. 따라서 시스템의 정지없이 전기분해 원리를 이용하여 만들어진 처리수를 순환시킴으로서 스케일의 원인물질은 Ca, Mg, $SiO_2$를 고형물 형태로 석출시켜 배관계 외부로 배출시킴으로서 배관내 스케일 발생을 차단하고 기 형성된 스케일을 제거하여 배관의 전열 성능을 유지하고자 하는 것이다. 실험한 결과, 새 배관의 열전달율을 100으로 기준할 경우, 스케일이 형성된 배관의 열전달율은 86.66%이었으며, 스케일이 형성된 배관을 1개월 동안 처리수를 가동했을 경우 열전달율은 90.5%의 수준까지 회복되었으며, 2개월간 운전한 경우 97.86%의 수준까지, 3개월 운전했을 경우 98.72%까지 열전달율이 회복되었다. 비교적 짧은 실험기간이지만 배관내 형성된 스케일의 제거효과를 파악하였으며, 전열성능에도 영향을 미치고 있음을 확인하였다.

드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구 (A study on design for free cooling system using dry cooler)

  • 윤정인;백승문;허정호;김영민;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1027-1031
    • /
    • 2014
  • 외기냉수냉방 시스템은 공조나 산업공정에 사용되는 냉수를 저온의 외기를 이용하여 냉각하는 시스템으로 에너지를 절감하기위해 사용되며, 냉각시스템과 외기와 냉수가 열교환을 하는 드라이쿨러로 구성되어있다. 외기냉수냉방 시스템은 지속적인 냉방이 필요한 곳에 에너지절감효과가 뛰어나나 국내의 경우, 외기냉수냉방 시스템에 설계 기준과 자료가 미비하다. 따라서 본 연구에서는 상용프로그램 HYSYS를 이용하여, 드라이쿨러를 이용한 외기냉수냉방 시스템의 요소변화에 따른 성능을 비교 분석했으며 그 결과는 다음과 같다. 드라이쿨러의 냉각능력은 외기온도, 요구냉수온도, 열교환기의 LMTD (Logarithmic Mean Temperature Difference, 대수평균온도차)에 따라 변한다. 드라이쿨러는 외기온도가 낮을 수록 그 냉각능력이 증가하며, LMTD가 낮은 드라이쿨러가 LMTD가 높은 것에 비하여 고온의 외기온도에서 사용이 가능하였다. 외기온도가 극히 낮은 지역에서는 글리콜이 함유된 부동액을 사용해야하며 국내의 외기온도를 고려하였을 때, 글리콜농도 34%의 부동액이 적절한 것으로 판단된다. 냉동기에 적용될 작동유체의 경우, R22, R134a, R407C의 압축일을 비교했으며, R134a가 환경관련 규제와 에너지 사용측면에서 우수한 냉매로 사료된다.

보텍스튜브에서 랭퀴-힐쉬효과와 줄-톰슨효과가 에너지분리에 미치는 영향 (The Influence of Ranque-Hilsch Effect and Joule-Thomson Effect to Energy Separation in a Vortex Tube)

  • 유갑종;방창훈;김병하
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.703-710
    • /
    • 2000
  • Energy separation characteristic occurring in a counterflow vortex tube was studied experimentally, where air, $C_2$, and R22 were used as working fluids. The experiments were carried out with pressure ratio from 3 to 8 and cold mass fraction(y) from 0.1 to 0.9. As results, Ranque-Hilsch effect showed different results from adiabatic expansion process. Temperature difference in vortex tube outlet was affected by Joule-Thomson effect as well as Ranque-Hilsch effect. The more effective the energy separation was, the more increased the entropy in the cold oulet of vortex tube was.

  • PDF

Evaluation of the Impacts of Stack Effect in High-Rise Buildings

  • Yang, In-Ho;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.91-103
    • /
    • 2003
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impacts on the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal air flow resistance. Therefore the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

고층건물에서의 연돌효과 시뮬레이션 (Simulation of the Stack Effect in High-Rise Builbings)

  • 양인호;여명석;조재훈;김광우
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.456-467
    • /
    • 2002
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impact of the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal airflow resistance, so the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.