PF열교환기에서 R410A 냉매분배의 영향 (Analysis of R410A refrigerant distribution in parallel flow heat exchanger)

  • 김정식;김내현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2008
  • A computer program, which simulates the parall flow evaporator was developed. The program was having used to simulate the sample $650\;mm{\times}190\;mm$ frontal area, 25 mm flow depth and 3.0 mm fin pitch. It was shown that the cooling capacity of 3kW could be available from the sample. The present model, however, does not consider refrigerant mal-distribution in each pass, which is known to reduce the cooling capacity of the parallel flow heat exchanger.

  • PDF

Flow and Pressure Drop Characteristics of R22 in Adiabatic Capillary Tubes

  • Kim, Min-Soo;Kim, Sung-Goo;Ro, Sung-Tack
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1328-1338
    • /
    • 2001
  • The objective of this study is to present flow and pressure drop characteristics of R22 in adiabatic capillary tubes of inner diameters of 1.2 to 2.0mm, and tube lengths of 500 to 2000mm. Distributions of temperature and pressure along capillary tubes and the refrigerant flow rates through the tubes were measured for several condensing temperatures and various degrees of subcooling at the capillary tube inlet. Condensing temperatures of R22 were selected as 40, 45, and 50$^{\circ}C$ at the capillary tube inlet, and the degree of subcooling was adjusted to 1 to 18$^{\circ}C$. Experimental results including mass flow rates and pressure drops of R22 in capillary tubes were provided. A new correlation based on Buckingham II theorem to predict the mass flow rate through the capillary tube was presented considering major parameters which affect the flow and pressure drop characteristcis.

  • PDF

수평 평활관내에서 비공비혼합냉매의 강제대류 증발열전달 (Forced Convective Evaporating Heat Transfer of Non-azeotropic Refrigerant Mixtures in a Horizontal Smoothed Tube)

  • 박기원;오후규
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.225-233
    • /
    • 1995
  • Experiments were performed to investigate the heat transfer characteristics of nonazeotropic mixture R-22+R-114 in a heat pump system. The ranges of parameter, such as heat flux, mass flow rate, and quality were $8,141{\sim}32,564W/m^2$, 24~58kg/h, and 0~1, respectively. The overall compositions of the mixtures were 50 and 100 per-cent of R-22 by weight for R-22+R-114 mixture. The results indicated that there were distinct different heat transfer phenomena between the pure substance and the mixture. In case of pure refrigerant the heat transfer rates for cooling were strongly dependent upon quality of the refrigerant. Overall evaporating heat transfer coefficients for the mixture were somewhat lower than pure R-22 values in the forced convective boiling region. For a given flow rate, the heat transfer coefficient at the circumferential tube wall(top, side, and bottom of the test tube) for R-22/R-114(50/50wt%)mixture, however, was higher than for pure R-22 at side and bottom of the tube. Furthermore, a prediction for the evaporating heat transfer coefficient of the mixtures was developed based on the method of Yoshida et.al.'s. The resulting correlation yielded a good agreement with the data for the refrigerant mixtures.

  • PDF

R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성 (Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.

  • PDF

에어컨디셔너의 냉매배관을 연결하는 커플링의 유동해석 (Flux Analysis of Air-conditioner Coupling)

  • 이수열;김우승;조수;성욱주;박희문;심경종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1031-1036
    • /
    • 2009
  • This study is intended to identify how quick disconnect coupling which connects with refrigerant piping of air-conditioner using R-22 refrigerant has effect on characteristics of flux. in the case where the air-conditioner installs utilizes quick disconnect coupling, COP has an effect on the quantity of cooling load because of changing flow rate and physical properties of refrigerant which flow into an entrance of expansion valve from coupling. Variation of flow rate can be regulated by changing expansion-contraction angle; $\alpha$ of an entrance and an exit of coupling. In this study, quick disconnect coupling is presented flow of coupling by using FLUENT as heat flow program. To have an effect on the expansion entrance valve, and by changing expansion-contraction angle; $\alpha$ of an entrance and an exit

  • PDF

암모니아-물 흡수식 열교환 사이클의 운전 특성 (Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle)

  • 강인석;김남진;김종보
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.357-362
    • /
    • 2001
  • 충진농도, 냉매 팽창밸브 개도, 그리고 약용액의 유량 변화에 따른 벤치타입 암모니아-물 흡수식 열교환 사이클에 대한 실험을 수행한 결과 시스템의 충진농도가 증가할수록 냉방능력이 증가하였으며, 최적의 충진농도가 존재함을 알았다. 그리고 냉매 팽창 밸브의 개도는 응축기 출구의 직접적인 영향을 주고 있으며 최적의 과냉도가 0~4$^{\circ}C$임을 알았다. 또한 약용액의 유량이 증가시킬수록 증발압력과 강용액의 농도가 즐어들었으며, 냉방능력과 COP가 최대가 되는 최적의 약용액 유량이 존재하였다.

  • PDF

R123 열원 적용 증발식 담수 시스템 특성 연구 (Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source)

  • 윤상국;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

핀-관 열교환기의 모델링 (Modeling of Fin-Tube Heat Exchanger)

  • 박희용;이관수;박동규
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.952-961
    • /
    • 1989
  • 본 연구에서는 널리 사용되는 핀-관 직교류 열교환기의 정상 상태를 예측 하기 위하여 냉매의 상변화에 따른 유체의 물성치, 열전달계수 및 마찰계수의 변화와 관벽에서의 축방향 열전도를 고려한 모형을 세우고 이를 분석하여 열교환기의 종합적 인 특성을 규명하고자 한다.

PID 제어를 이용한 멀티형 열펌프의 용량조절 (Capacity Modulation of a Multi-Type Heat Pump System Using PID Control)

  • 정대성;김민성;김민수;이원용
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.446-475
    • /
    • 2000
  • Performance of a water-to-water multi-type heat pump system using R22 has been experimentally investigated. Total refrigerant flow rate was adjusted with a variable speed compressor and the refrigerant flow rate for two indoor units were controlled by electronic expansion valves. Evaporator outlet pressure of refrigerant and indoor unit outlet temperatures of secondary fluid were selected as controlled variables. Experiments were carried out for both cooling and heating modes using PID control method. Results show that the multi-type heat pump system can be adequately controlled by keeping control gains at certain levels for various operating conditions.

  • PDF

퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절 (Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic)

  • 김세영;김민수
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF