• Title/Summary/Keyword: Refraction error

Search Result 109, Processing Time 0.024 seconds

Developing GPS Code Multipath Grid Map (CMGM) of Domestic Reference Station (국내 기준국의 GPS 코드 다중경로오차 격자지도 생성)

  • Gyu Min Kim;Gimin Kim;Chandeok Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.1
    • /
    • pp.85-92
    • /
    • 2024
  • This study develops a Global Positioning System (GPS) Code Multipath Grid Map (CMGM) of each individual domestic reference station from the extracted code multipath of measurement data. Multipath corresponds to signal reflection/refraction caused by obstacles around the receiver antenna, and it is a major source of error that cannot be eliminated by differencing. From the receiver-independent exchange format (RINEX) data for two days, the associated code multipath of a satellite tracking arc is extracted. These code multipath data go through bias correction and interpolation to yield the CMGM with respect to the azimuth and elevation angles. The effect of the CMGM on multipath mitigation is then quantitatively analyzed to improve the Root Mean Square (RMS) of averaged pseudo multipath. Furthermore, the single point positioning (SPP) accuracy is analyzed in terms of the RMS of the horizontal and vertical errors. During two weeks in February 2023, the RMSs of the averaged pseudo multipath for five reference stations decreased by about 40% on average after CMGM application. Also, the SPP accuracies increased by about 7% for horizontal errors and about 10% for vertical errors on average after CMGM application. The overall quantitative analysis indicates that the proposed approach will reduce the convergence time of Differential Global Navigation Satellite System (DGNSS), Real-Time Kinematic (RTK), and Precise Point Positioning (PPP)-RTK correction information in real-time to use measurement data whose code multipath is corrected and mitigated by the CMGM.

Optimal Geometric Design of Secondary Mirror Supporter in Catadioptric Optical System for Observation Reconnaissance Using Response Surface Methodology (반응 표면 분석법을 이용한 감시 정찰용 반사 굴절 광학계 부경 지지대의 형상 최적 설계)

  • Lee, Sang Eun;Kim, Dae Hee;Lee, Tae Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.435-442
    • /
    • 2017
  • A catadioptric optical system produces images by refraction and reflection. To improve the image quality, the shape of the secondary mirror supporters should be determined to ensure that the centering error and tilt of secondary mirror are very small, and the main mirror receives the maximum amount of light. Furthermore, random acceleration vibration has a severe effect on the optical system for observation reconnaissance. In order to obtain the best design under these circumstances, the volume of the secondary mirror supporter must be minimized while satisfying the constraints expressed in standard deviations of the centering error and tilt. It is difficult to analytically calculate the design sensitivities of the standard deviations, because they are statistically defined. Hence, after their second-order regression equations were determined using a response surface methodology, an optimal geometric design was obtained. As a result, it was found that the method proposed in this paper, which included a random vibration analysis, was effective in obtaining the optimal design for a secondary mirror supporter with robustness.

Study on the Correlation between Refractive error and Components of Eye's Optical system in Children and Teenagers in an Optometric Practice (안과 병원을 내원한 소아 청소년의 굴절이상과 안광학 성분간의 상관관계 연구)

  • Ha, Na-Ri;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.67-74
    • /
    • 2012
  • Purpose: The purpose of this study to evaluate visual acuity and refractive state and measure and analyze the components of eye's optical system in children and teenagers. Methods: With subjects of 124 (230 eyes) children and teenagers who had no eye diseases, correlation between the correlation between refractive errors and component's of eye's optical system was investigated. The spherical equivalent power of cycloplegic clinical refraction or manifest clinical refraction(SE), corneal power(CP), corneal radius(CR), axial length(AL), anterior chamber depth(ACD) and axial length to corneal radius (AL/CR) ratio were measured and analysed. Results: the SE was negatively correlated with the AL(r = -0.80, p = 0.00), the ACD(r = -0.35, p = 0.00) and the CR(r = -0.11, p=0.00) and positively correlated with the CP(r = +0.11, p=0.00). The AL was positively correlated with the AL/CR ratio (r = +0.84, p = 0.00), the ACD(r = +0.47, p=0.00) and the CR(r = +0.38, p = 0.00) and negatively correlated with the CP(r = -0.38, p=0.00). The CR was negatively correlated with CP(r = -1.00, p = 0.00), the AL/CR ratio(r = -0.19, p = 0.00) and the ACD(r = -0.06, p = 0.39). The CP was positively correlated with the AL/CR ratio(r = +0.19, p = 0.00) and the ACD(r = +0.06, p = 0.39). The ACD was positively correlated with the AL/CR ratio(r = 0.53, p = 0.00). Conclusions: the highest change of refractive errors was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive errors of the children and teenagers.

A Study on the Changes of Accommodative Function in Respect to the Viewing Angle (주시각도에 따른 조절기능의 변화)

  • Lee, Hark-Jun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: The purpose of this study was to examine the relationship between the accommodative facility, blink rate and accommodative lag according to the change of angles of main viewpoint of near distance worker and study an appropriate viewing angle that mitigates asthenopia, such as headaches or eye fatigue accompanied when reading and staring at the computer or TV for a long time. Methods: Total of 27 people including 12 male university students and 15 female university students in the age of 20 to 36 with frequent near distance works, such as computers, were selected to study the accommodative facility, the blink rate and the accommodative lag in accordance with the change of viewing angles of the near distance workers. The refraction error was corrected completely and the phoropter was shifted to near distance mode to locate the near distance indication at 40 cm. The accommodative facility and the blink rate were measured for one minute at each viewing direction of $40^{\circ}$ downward, $20^{\circ}$ downward, horizontal, and $20^{\circ}$ upward directions based on the horizontal line and the accommodative lag was measured in dynamic retinoscopy using retinoscope. Results: As a result, when the main viewpoint was moved on upper direction from the $40^{\circ}$ below, the accommodative facility was reduced and the blink rate and the accommodative lag were increased so their eyes became dry and the accommodation response was reduced. Conclusions: In near distance works, the eye fatigue level can be minimized by locating a book or a computer screen $40^{\circ}$ below than the horizontal direction.

  • PDF

An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer (액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법)

  • Son, Gong-Sook;Park, Chan;Park, Hee-Gap;Kim, Jin-Seung;Rho, Bong-Gyu;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.213-218
    • /
    • 1996
  • An improved crystal rotation method with increased accuracy and range is proposed and experimentally verified for simultaneous measurement of molecular tilt angle and thickness of LC (liquid crystal) layer of an LC cell. The improvement is brought about by direct determination of difference between phases instead of intensities of two components of orthogonal linear polarization of the light passing through an LC cell filled with uniformly oriented molecules. By comparing the experimental data with theoretical result the thickness and pretilt angle are determined more precisely. Further improvement is brought about by use of a liquid gate filled with an index matching liquid in which the LC cell is immersed. Because of the index matching liquid reflection of light at the surfaces of an LC cell almost completely disappears and the range of angle of refraction in the LC layer increases significantly, which gives rise to increased signal to noise ration as well as decreased statistical error. With this improvement precise measurement for either very thin (<10 ${\mu}{\textrm}{m}$) and/or higher pretilt angle($\geq$10$^{\circ}$) LC cells become possible.

  • PDF

Electromagnetic Traveltime Tomography with Wavefield Transformation (파동장 변환을 이용한 전자탐사 주시 토모그래피)

  • Lee, Tae-Jong;Suh, Jung-Hee;Shin, Chang-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 1999
  • A traveltime tomography has been carried out by transforming electromagnetic data in frequency domain to wave-like domain. The transform uniquely relates a field satisfying a diffusion equation to an integral of the corresponding wavefield. But direct transform of frequency domain magnetic fields to wave-field domain is ill-posed problem because the kernel of the integral transform is highly damped. In this study, instead of solving such an unstable problem, it is assumed that wave-fields in transformed domain can be approximated by sum of ray series. And for further simplicity, reflection and refraction energy compared to that of direct wave is weak enough to be neglected. Then first arrival can be approximated by calculating the traveltime of direct wave only. But these assumptions are valid when the conductivity contrast between background medium and the target anomalous body is low enough. So this approach can only be applied to the models with low conductivity contrast. To verify the algorithm, traveltime calculated by this approach was compared to that of direct transform method and exact traveltime, calculated analytically, for homogeneous whole space. The error in first arrival picked by this study was less than that of direct transformation method, especially when the number of frequency samples is less than 10, or when the data are noisy. Layered earth model with varying conductivity contrasts and inclined dyke model have been successfully imaged by applying nonlinear traveltime tomography in 30 iterations within three CPU minutes on a IBM Pentium Pro 200 MHz.

  • PDF

The Age-specific Change of Refraction(D) Power and Relative Risks of Refractive Errors (연령에 따른 굴절력 변화와 굴절이상의 상대 위험도)

  • Lee, Eun-Hee;Lee, Sang-Yoon;Lee, Hee-Jung;Cho, Sung-Il;Paek, Domyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.1-5
    • /
    • 2007
  • This is a succeeding article of J. Korean Optalmic Optics Society vol. 11(2) pp. 121-129(2006) [Research about the distribution of refractive errors in distinction of gender and at age of Kyonggi province's partial area]. The former article showed age-specific distribution of myopia, hyperopia and astigmatism which generally appears in refractive errors. This paper aimed to investigate the change of refractive power and prevalence of refractive errors by age. Total 928 subjects were sampled and their refractive errors were determined using auto refractometer. As the results, change of refractive power of subjects appeared at the age about 40, and suddenly reduced over 46 years resulting in (+)refractive power at their fifties. Relative risks of refractive errors of myopia increased in younger subjects but the risks decreased in older subjects (over 46 years). On the other hand, the risks of hyperopia decreased as the age of subjects increase, but could increase to 0.24 (95% CI: 0.07-0.88) after 36 years. This results showed that presbyopia might progress more early when people were before 40 years.

  • PDF

DEEP SPACE NETWORK MEASUREMENT MODEL DEVELOPMENT FOR INTERPLANETARY MISSION (행성간 탐사를 위한 심우주 추적망 관측모델 개발)

  • Kim, Hae-Yeon;Park, Eun-Seo;Song, Young-Joo;Yoo, Sung-Moon;Rho, Kyung-Min;Park, Sang-Young;Choi, Kyu-Hong;Yoon, Jae-Cheol;Yim, Jo-Ryeong;Choi, Jun-Min;Kim, Byung-Kyo
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.361-370
    • /
    • 2004
  • The DSN(Deep Space Network) measurement model for interplanetary navigations which is essential for precise orbit determination has been developed. The DSN measurement model produces fictitious DSN observables such as range, doppler and angular data, containing the potential observational errors in geometric data obtained from orbit propagator. So the important part of this research is to model observational errors in DSN observation and to characterize the errors. The modeled observational errors include the range delay effect caused by troposphere, ionosphere, antenna offset, and angular refraction effect caused by troposphere. Non-modeled errors are justified as the parameters. All of these results from developed models show about $10\%$ errors compared to the JPL's reference results, that are within acceptable error range.

Bleaching Observation of Cosmetic Color Lenses According to Multipurpose Contact Lens Solutions (다목적 콘택트렌즈 용액에 대한 미용 칼라렌즈의 탈색 관찰)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.295-303
    • /
    • 2014
  • Purpose: This study aims to observe bleaching resulted from multipurpose contact lens solutions used to manage lenses with the subjects of colored contact lenses being distributed in Korea. Methods: The lenses have been worn for six months, and their refraction is 0.00D. Three types of colored contact lenses of which margin has been colored with a different manufacturing method have been adopted (type 1: pigment application method, type 2: chemical bonding process, type 3: sandwich method), and multipurpose solutions used were two types containing different components. Each of the colored contact lenses was stored in the multipurpose solutions for 20 days and went through vortexing for 15 seconds per day. Their fluorescence absorbance, surface roughness, brightness index, and color coordinate index were measured before and after the vortexing to see the degree of bleaching. Results: In the two types of multipurpose solutions, every type of the color contact lenses showed no statistically significant difference in their fluorescence absorbance value before and after the vortexing. Regarding surface image, the front surface of the lenses was smooth in every type, and about the back surface, type 3 indicated less protrusion than type 1 and 2. About the difference of color on the lens surface before and after the vortexing, type 3 showed significantly less difference than type 1 and 2; however, all fell into the permissible error. Conclusions: About the bleaching of colored contact lenses resulted from multipurpose solutions for soft contact lenses, there was no difference observed in terms of fluorescence absorbance and color. According to the methods of manufacturing dyes, however, there was difference in the protrusion of the posterior surface image.

Association between Axial Length and Anthropometric Value in Korean Children (한국 어린이의 안축장과 신체 계측치와의 관련성)

  • Kim, Hyojin;Lyu, Jungmook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.397-402
    • /
    • 2014
  • Purpose: To investigate the relationship between axial length (AL) and anthropometric parameters in Korean children. Methods: This study included 40 urban school children aged 11-12 years (mean age, $11.95{\pm}0.22$ years; 45.0% girls) residing in Seoul, South Korea. AL (using partial coherence laser interferometry), corneal radius, refractive error, height (m), and weight (kg) were measured. Body mass index (BMI $[kg/m^2]=weight/[height]^2$) and degree of obesity (DO[%]=[actual weight standard weight]/standard weight) were calculated. Furthermore, the number of hours spent reading, watching television, and using a computer every day was determined using a detailed questionnaire. Results: The students had a mean spherical equivalent refraction of $1.06{\pm}0.84$ D. Weight (r=0.427, p=0.006), BMI (r=0.508, p=0.001), and DO (r=0.371, p=0.018) showed a significant positive correlation with AL. Furthermore, longer AL was significantly associated with heavier weight (p=0.041), and higher BMI (p=0.015), and higher DO quartiles (p=0.042). After adjust for age, sex, and near-work activities, multivariate linear regression models showed that weight, BMI, and DO were still significantly associated with AL. Among the near-work activities, daily reading time was significantly associated with AL. Conclusions: AL was positively related to weight as well as daily reading time in Korean urban school children.