• Title/Summary/Keyword: Reflection Ratio

Search Result 415, Processing Time 0.021 seconds

Residual Stress Measurement on T-type Welded Specimen by Neutron Diffraction

  • Jang, D.Y.;Park, M.J.;Choi, H.D.;Kim, J.P.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.2
    • /
    • pp.45-50
    • /
    • 2001
  • This paper presents application of neutron diffraction technique to the measurement of residual stresses in the T-type 20 m thick welded stainless steel plates(100$\times$50 $mm^2$ and 50$\times$50 $mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute was utilized in the measurement. The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$)was $92.66^{\circ}$. Poisson ratio of 0.265 and elastic constant of 211 GPa were applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses were measured. The results showed that three components were tensile and became compressive along the y axis in the zone away from the welded center. The compressive stresses became tensile in the zone away from the center line of x axis. This may be due to the balance effect caused by the net stress to keep the specimen shape flat.

  • PDF

Residual Stress Measurement on Welded Stainless Steel Specimen by Neutron Diffraction

  • Park, M.J.;Jang, D.Y.;Choi, H.D.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • In this paper, the neutron diffraction is applied to the residual stress measurement on the 20mm-thick welded stainless steel plate ($100^{\circ}$$\times$100$mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$ is $95^{\circ}$and wavelength is 1.8340 ${\AA}$ . The Poisson ratio of 0.265 and elastic constant of 211 GPa are applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses are measured and the results show that the most of longitudinal stress is tensile and decreases, changing to compressive depending on the distance away from the welded spot. However, transverse component is changing from tensile to compressive along the depth of the welded point.

  • PDF

Seismic interval velocity analysis on prestack depth domain for detecting the bottom simulating reflector of gas-hydrate (가스 하이드레이트 부존층의 하부 경계면을 규명하기 위한 심도영역 탄성파 구간속도 분석)

  • Ko Seung-Won;Chung Bu-Heung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.638-642
    • /
    • 2005
  • For gas hydrate exploration, long offset multichannel seismic data acquired using by the 4km streamer length in Ulleung basin of the East Sea. The dataset was processed to define the BSRs (Bottom Simulating Reflectors) and to estimate the amount of gas hydrates. Confirmation of the presence of Bottom Simulating reflectors (BSR) and investigation of its physical properties from seismic section are important for gas hydrate detection. Specially, faster interval velocity overlying slower interval velocity indicates the likely presences of gas hydrate above BSR and free gas underneath BSR. In consequence, estimation of correct interval velocities and analysis of their spatial variations are critical processes for gas hydrate detection using seismic reflection data. Using Dix's equation, Root Mean Square (RMS) velocities can be converted into interval velocities. However, it is not a proper way to investigate interval velocities above and below BSR considering the fact that RMS velocities have poor resolution and correctness and the assumption that interval velocities increase along the depth. Therefore, we incorporated Migration Velocity Analysis (MVA) software produced by Landmark CO. to estimate correct interval velocities in detail. MVA is a process to yield velocities of sediments between layers using Common Mid Point (CMP) gathered seismic data. The CMP gathered data for MVA should be produced after basic processing steps to enhance the signal to noise ratio of the first reflections. Prestack depth migrated section is produced using interval velocities and interval velocities are key parameters governing qualities of prestack depth migration section. Correctness of interval velocities can be examined by the presence of Residual Move Out (RMO) on CMP gathered data. If there is no RMO, peaks of primary reflection events are flat in horizontal direction for all offsets of Common Reflection Point (CRP) gathers and it proves that prestack depth migration is done with correct velocity field. Used method in this study, Tomographic inversion needs two initial input data. One is the dataset obtained from the results of preprocessing by removing multiples and noise and stacked partially. The other is the depth domain velocity model build by smoothing and editing the interval velocity converted from RMS velocity. After the three times iteration of tomography inversion, Optimum interval velocity field can be fixed. The conclusion of this study as follow, the final Interval velocity around the BSR decreased to 1400 m/s from 2500 m/s abruptly. BSR is showed about 200m depth under the seabottom

  • PDF

A Study on Infrared Emissivity Measurement of Material Surface by Reflection Method (반사법에 의한 재료표면의 적외선 방사율 측정에 관한 연구)

  • Kang, Byung-Chul;Kim, Sang-Myoung;Choi, Joung-Yoon;Kim, Gun-Ok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.484-488
    • /
    • 2010
  • Infrared emissivity is one of the most important factors for the temperature measurement by infrared thermography. Although the infrared emissivity of an object can be measured from the ratio of blackbody and the object, at room temperature it is practically difficult to measure the value due to the background effects. Hence, quantitative reflectance of bare steel plate and the surface of coating was measured by FT-IR spectroscopy and emissivity was calculated from this. The emissivity of polished bare steel surface was from 0.06 to 0.10 and the value for the unpolished bare steel can not be achieved because optical characteristics changes of surface roughness induces erroneous results. Emissivity of transparent paint coated steel was from 0.50 to 0.84. Depends on the IR absorption regions, which is a characteristic value of the coating, emissivity changes. This study suggests surface condition of material, thickness, roughness et cetra are important factor for IR optical characteristics. Emissivity measurement by reflection method is useful technique to be applied for metal and it with coating applied on the surface. The range of experimental errors of temperature can be narrowed by the application of infrared thermography from the measured thermal emissivity.

Seismic reflection survey in a tidal flat: A case study for the Mineopo area (갯벌 지역에서의 탄성파 탐사: 민어포 조간대 지역의 사례)

  • Jou Hyeong-Tae;Kim Han-Joon;Lee Gwang-Hoon;Choi Dong-Lim;Kim Min-Ji;Cho Hyun-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.67-84
    • /
    • 2002
  • A shallow high-resolution seismic reflection survey was carried out at the Mineopo tidal flat on the western coast of Korea. The purpose of the survey was to investigate shallow sedimentary structure of the tidal (fat associated with the recent sea level change. A total of 795 shots were generated at 1 m interval from a 5-kg hammer source and recorded on 48 channels of 100 Hz geophones along two mutually perpendicular profiles. The water-saturated ground condition resulted in suppressed ground rolls by significantly decreasing rigidity. In addition, seismic velocities over 1500 m/s provided easy segregation of reflected arrivals from lower velocity noise. As a consequence, seismic sections were created that are high in resolution and signal to noise ratio as well. The stack sections show that the tidal flat consists of 5 sedimentary sequences above acoustic basement. Although deposition is largely characterized by the transgressive sedimentary facies resulting from sea level rise, erosional surfaces are well-resolved within the sequences.

  • PDF

Simulation and Examination for Beam Profile of DFB Laser with an Anti-reflection Coated Mirror (무반사 면을 갖는 DFB 레이저의 빔 분포 시뮬레이션과 검정)

  • Kwon, Kee-Young;Ki, Jang-Geun
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.1
    • /
    • pp.55-63
    • /
    • 2020
  • Lasers for optical broadband communication systems should have excellent frequency selectivity and modal stability. DFB lasers have low lasing frequency shift during high speed current modulation. In this paper, when a refractive index grating and a gain grating are simultaneously present in a DFB laser having a wavelength of 1.55 ㎛, the dielectric film is coated so that reflection does not occur on the right mirror surface, so that ρr=0. For the first mode, which requires a minimum gain at the threshold, the beam distribution of the oscillation mode in the longitudinal direction and the radiated power ratio Pl/Pr were analyzed and compared for the cases of the phase of ρl=π and π/2. If the phase of ρl=π, in order to obtain a low threshold current and high frequency stability, κL should be greater than 8. In the case of the phase of ρl=π/2, for low threshold current, κL is necessary to be 1.0, where the oscillation frequency coincides with the lattice frequency. DFB lasers with an anti-reflection coated mirror have excellent mode selectivity than 1.55um DFB lasers with two mirror facets

The methodology on the application of EEG as a diagonostic measures in Korean Traditional Medicine (뇌파의 한의학적 진단 지표로의 활용 방안에 대한 연구초안)

  • Seo, Young-Hyo;Kim, Gyeong-Cheol;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.18 no.1
    • /
    • pp.37-61
    • /
    • 2007
  • Objective : By examining EEG status in Korean Traditional Medicine (KTM) from the viewpoint of 'form-qi theory(形氣論)', We wish to prepare for the fundamentals of applicability of KTM diagnoses to EEG. In addition, through reinterpretation of existing Western Medicine reports from the viewpoint of KTM, We tried to find out interrelationship between them. Method : In this paper, a methodology applicable to KTM diagnoses of EEG is presented from the EEG features in waveform characteristics, personalized diversity, and cognitive activity reflection. Results : Frequency bands are assigned to corresponding one of the eight trigrams in terms of yin/yang balance, which is analogous with EEG spectrum analysis mostly used in EEG quantification. The amplitude ratio of each EEG for each frequency band gives meaningful index numbers which can be used in EEG data interpretation, and every index number is named after the sixty four hexagrams. These approaches are adopted through both '4-band classification system and '6-band classification system', and applied to pre-existing reported EEG data obtained from normal adults. These analyses show that changes and distribution pattern in the index numbers are observed as a whole on both left-right line and front-back line connecting EEG measurement cephalic electrodes. And differences in distribution pattern of three index numbers deduced from '6-band classification system' are discussed according to constitution. Conclusion : The index numbers introduced here, which are the spectral power ratio for each EEG, are based on KTM yin/yang balance. These index numbers vary according to cephalic location, so its application in terms of traditional meridian theory is strongly expected. The index number distribution also shows different patterns according to constitution.

  • PDF

Design of a Conical Spiral Antenna for Satellite TT&C Applications (위성 TT&C용 원뿔 나선 안테나 설계)

  • Ko Han-Woong;Lee Junwen;Yu Jae-Deok;Kim Se-Yon;Ahn Bierng-Chearl;Park Dong-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.24-38
    • /
    • 2006
  • In this paper, we investigate the design and fabrication of a conical spiral antenna suitable for satellite TT&C applications. The shape of the spiral is optimized using a commercial electromagnetic software for good gain and axial ratio performances over $2.0{\sim}2.3\;GHz$ frequencies. A coaxial infinite balun feeding the spiral is designed using experimental methods. A method for precision fabrication of the spiral is presented. Measurements of the fabricated antenna show satisfactory performances over $2.0{\sim}2.3\;GHz$ such as a reflection coefficient less than -18 dB, a maximum gain greater than 4 dB, a gain greater than 0 dB over angles ${\pm}75^{\circ}$ from the antenna boresight, an axial ratio less than 5 dB over angles ${\pm}90^{\circ}$ from the antenna boresight, a front-back ratio greater than 15 dB.

Effect of intracanal medicaments used in endodontic regeneration procedures on microhardness and chemical structure of dentin

  • Yassen, Ghaeth Hamdon;Eckert, George Joseph;Platt, Jeffrey Allen
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.104-112
    • /
    • 2015
  • Objectives: This study was performed to investigate the effects of different intracanal medicaments on chemical structure and microhardness of dentin. Materials and Methods: Fifty human dentin discs were obtained from intact third molars and randomly assigned into two control groups and three treatment groups. The first control group received no treatment. The second control group (no medicament group) was irrigated with sodium hypochlorite (NaOCl), stored in humid environment for four weeks and then irrigated with ethylenediaminetetraacetic acid (EDTA). The three treatment groups were irrigated with NaOCl, treated for four weeks with either 1 g/mL triple antibiotic paste (TAP), 1 mg/mL methylcellulose-based triple antibiotic paste (DTAP), or calcium hydroxide [$Ca(OH)_2$] and finally irrigated with EDTA. After treatment, one half of each dentin disc was subjected to Vickers microhardness (n = 10 per group) and the other half was used to evaluate the chemical structure (phosphate/amide I ratio) of treated dentin utilizing attenuated total reflection Fourier transform infrared spectroscopy (n = 5 per group). One-way ANOVA followed by Fisher's least significant difference were used for statistical analyses. Results: Dentin discs treated with different intracanal medicaments and those treated with NaOCl + EDTA showed significant reduction in microhardness (p < 0.0001) and phosphate/amide I ratio (p < 0.05) compared to no treatment control dentin. Furthermore, dentin discs treated with TAP had significantly lower microhardness (p < 0.0001) and phosphate/amide I ratio (p < 0.0001) compared to all other groups. Conclusions: The use of DTAP or $Ca(OH)_2$ medicaments during endodontic regeneration may cause significantly less microhardness reduction and superficial demineralization of dentin compared to the use of TAP.

Correlation between HRV and Bowel Sound Parameters in the Evaluation of Gastrointestinal Parasympathetic Nerve Activity from Patients with Functional Dyspepsia (기능성 소화불량증에서 위장관 미주신경 활성 평가를 위한 심박변이지표와 장음지표의 상관성 연구)

  • Kim, So-Yeon;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.173-180
    • /
    • 2009
  • Objectives : The aim of this study was to investigate the evaluation of gastrointestinal parasympathetic nerve activity by comparing between HRV and bowel sound parameters in patients with functional dyspepsia. Methods : 62 patients (male 22, female 40) were enrolled. HRV was measured in all patients. and TP (total power), LF (low frequency density: 0.04$\sim$0.15Hz), HF (high frequency density: 0.15$\sim$0.4Hz). and LF/HF ratio were analyzed. HF band is a reflection of parasympathetic activity. and the LF-to-HF ratio is considered a marker of sympathovagal balance. Bowel sounds were recorded at the day after, and postprandial %BS was used to indicate the gastric vagal activity after eating. HRV and bowel sound parameters were compared. and correlation between them was analyzed. Results : There was no difference in LF/HF ratio between patient group and healthy group of other report. According to values of %BS, each patient was classified into a normal (>6 %BS) or hypoactivity (<6 %BS) of gastric vagus nerve group. HF component of the hypoactivity group was not significantly higher than that of the normal group. There was no correlation between HRV and bowel sound parameters. Conclusions : Because no correlation was found between HRV and bowel sound parameters in patients with functional dyspepsia, we concluded that it is not proper to evaluate gastric vagus nerve activity by HRV measurement.

  • PDF