• 제목/요약/키워드: Reflecting Optical System

검색결과 41건 처리시간 0.026초

형광 공초점 주사 현미경의 측정 강도 향상을 위한 반사 광학계의 제안 및 설계 (Proposal and design of reflecting optical system to improve detection intensity in fluorescence confocal scanning microscopy)

  • 강동균;서정우;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 2002
  • Confocal microscopy is very popular technology in bio-medical inspection due to its ability to reject background signals and to measure very thin slide of thick specimens, which is called optical sectioning. But intensity of detected signal in fluorescence type confocal microscopy is so small that only 0.2% of emitted fluorescence light can be detected in the best case. In this paper, we proposed the reflecting optical system to improve the detection intensity and designed the optical system by optimal design method. At the end of the paper, we analyzed the characteristics of the proposed reflecting optical system.

  • PDF

반사필터를 이용한 광선로 원격감시 시스템 (Optical Line Remote-Monitoring System Using Reflecting Filter)

  • 정소기;차경천
    • 한국통신학회논문지
    • /
    • 제39A권6호
    • /
    • pp.357-364
    • /
    • 2014
  • 본 논문은 반사필터를 사용하여 FTTH-PON의 원격제어 시스템을 다루고 있다. 기존의 FTTH-PON방식은 광케이블 고장과 수동분기소자(Splitter)의 품질 저하가 발생하는 것을 실시간 인지 할 수 없다. 본 연구에서는 이를 해결하기 위해서 광섬유 브래그 격자 원리를 이용한 반사필터를 개발하여 간선망과 Splitter를 감시 할 수 있게 하였다. 반사필터는 광케이블 밴딩, 커넥터 상태와 스플리터의 품질이 점진적으로 저하되는 것을 모니터링 하고 광케이블 고장, 수동 광분배기(Splitter) 등의 고장 위치를 확인하여 OLT측에 경보를 보내서 중앙관제에서 감시할 수 있는 시스템이다. 즉, 기존 통신 국사 측 파장분기 결합부(Coupler)를 이용해 1개의 광심선으로 live 파장과 감시용 파장을 2개로 보내어 가입자 측 장치인 모뎀과 집선 스위치에 반사필터를 사용하여 원격으로 광선로를 감시하는 시스템에 관한 연구이다. 이러한 반사필터의 개발로 인해 광선로 평균 고장처리 시간 단축과 효율적 유지보수를 할 수 있을 것으로 기대한다.

Analytical approximation of optical force on a perfectly reflecting sphere: ray-optics regime

  • Kim, Sang Bok;Song, Dong Keun
    • 한국입자에어로졸학회지
    • /
    • 제14권1호
    • /
    • pp.1-8
    • /
    • 2018
  • The optical force on a perfectly reflecting sphere in a ray-optics regime is considered. With the assumption of geometric optics and a sphere smaller than the minimum waist of the illuminating beam, closed-form analytic expressions of the optical force are derived. Both axial and radial forces are expressed by a modified Bessel function of the first kind. The derived analytic expressions are compared to precise numerical computations of the exact optical force equations derived previously. In addition the error due to the small sphere assumption is estimated analytically.

An Optical Cavity Design for an Infrared Gas Detector Using an Off-axis Parabolic Mirror

  • Jeong, You-Jin;Kang, Dong-Hwa;Seo, Jae-Yeong;Jo, Ye-Ji;Seo, Jin-Hee;Choi, Hwan-Young;Jung, Mee-Suk
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.374-381
    • /
    • 2019
  • This study examined a method for designing the optical cavity of a non-dispersive infrared gas detector. The infrared gas detector requires an optical cavity design to lengthen the ray path. However, the optical cavity with multiple reflecting surfaces has off-axis aberration due to the characteristics of the reflecting optical system. The rays were parallelized by using the off-axis parabolic mirror to easily increase the ray path and eliminate off-axis aberration so that the rays are admitted to the effective area of the infrared detector uniformly. A prototype of an infrared gas detector was produced with the designed optical cavity to confirm the performance.

광학용 유리자동검사기 개발에 관한 연구 (A Study on the development of Automated Optical Glass Inspection System)

  • 구마끼
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.82-87
    • /
    • 1998
  • Laser printer, faximile and copy machine are a few examples of OA(office automation) system. In such a system, the reflecting mirror has been employed for transmitting a target image to optical device. Therefore, to develope a good quality of optical system, the quality control of optical mirror was required. In recent years, considerable efforts have been directed toward the development of automated optical glass inspection system because the inspection is eye-fatigue and monotonous job for humans to perform. In this paper, we propose a inspection system applying algorithm of image processing for detecting defects of optical glass such as pinhole, scratch. From the experiments, the proposed inspection system shows reliable results.

  • PDF

광필터의 스펙트럼 검사시스템 개발 (A New System Development for the Spectrum Inspection of Optical Filters)

  • 김승철;김경범
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.57-64
    • /
    • 2006
  • Optical filters in WDM are passive communication components used in case of transmitting and reflecting lights with specific wavelengths. In this paper, a novel mechanism for the automatic and optical alignment has been presented. It includes minimum axes not to be coupled each other. The automatic spectrum inspection system has been developed to improve the alignment time of reference optical ray, spectrum inspection time and inspection quality, simultaneously. It has been confirmed that the proposed spectrum inspection system is faster, more precise and more reliable than those based on the conventional handwork.

정사각형 계의 전도-복사열전달에서 정반사면의 영향 (Effects of a Specularly Reflecting Wall in an Infinite Square Duct on Conductive-Radiative Heat Transfer)

  • 변기홍;한동천
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1451-1458
    • /
    • 2001
  • The effects of a specularly reflecting surface on the wall heat flux and medium temperature distribution are studied. The system is an infinite square duct enclosing an absorbing and emitting medium. The walls are opaque, and black or gray. The walls emit diffusely but reflect diffusely or speculary. Heat is transferred by the combined effect of conduction and radiation. The radiative heat transfer is analyzed using direct discrete-ordinates method. The parameters under study are conduction, to radiation parameter, optical depth, wall emissivity, and reflection characteristics. The specular reflection and diffuse reflection show sizeable differences when the conduction to radiation parameter is less than around 0.01. The differences appear only either on the side wall heat flux or on the medium temperature profiles for the range of this study. The differences on the side wall heat flux are observed for optical thickness less than around 0.1 However the differences on the medium temperate profiles are found for optical thickness greater than around 1. The difference increase with increasing reflectance. The specular reflection increases the well heat flux gradient along the side wall.

Signal increasing method in confocal scanning microscopy in fluorescence mode using curved mirror

  • Kang, Dong-kyun;Seo, Jung-woo;Gweon, Dae-gab
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.99.3-99
    • /
    • 2001
  • In fluorescence mode confocal scanning microscope, level of detected signal is very low. In object scanning type confocal scanning microscope, the additional optical system with objective lens and plane mirror was proposed to increase signal intensity, but there was none for beam scanning type confocal scanning microscope. We propose reflecting optical systems which improve signal intensity in beam scanning type confocal scanning microscope. We choose one of the proposed optical systems and design the optical system, i.e., select optical components and assign distances between the selected components. To design the optical system, we use finite ray tracing method and make cost function to be minimized.

  • PDF

DIFFRACTION ANALYSIS OF LAMOST - TWO SEGMENTED MIRRORS INCLUDED

  • Xu WENLI
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.399-400
    • /
    • 1996
  • LAMOST is a special reflecting Schmidt telescope. Both the refleting Schmidt plate $M_A$ and the spherical primary mitrror $M_B$ are segmened mirrors. These two cofocus but not co-phase. The diffraction of the optical system is decided by the shape overlapping of $M_A$ and $M_B$. This paper describes the diffraction caculating results with different declination and different field angle. The diffraction influence to the image quality is acceptable in the error buget of optical system. It also proves that the size seletion of the sub-mirror is reasonable.

  • PDF