• Title/Summary/Keyword: Reference-Pulse

Search Result 324, Processing Time 0.025 seconds

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF