• Title/Summary/Keyword: Reference target

Search Result 802, Processing Time 0.018 seconds

Comparison of Nutrient Intakes of Korean Elderly People Living in Rural Area Between 24-hour Recall and Food Frequency Method (24시간회상법과 식품섭취빈도조사법을 이용한 농촌지역 노인의 영양소 섭취수준 비교)

  • Cho, Young-Eun;Lee, Soo-Lim;Cho, Eun-Hyun;Lomeda, Ria-Ann L;Kwak, Eun-Hee;Kim, Yang-Ha;Kwun, In-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.6
    • /
    • pp.698-707
    • /
    • 2006
  • Precise and correct assessment of nutrient intake using appropriate dietary intake method is necessary to improve the nutritional status of the target people group. It is more likely so in elderly people since their dietary habits and inadequate nutrient intakes are of special concern even worse in rural areas. Two popular methods of gathering dietary intake are 24-hour recall and food frequency method (or food frequency questionnaire). In the present study, we conducted both 24-hour recall and food frequency method on 120 rural elderly people $(aged\;65{\sim}74\;years)$, 62 male and 58 female. The dietary intakes were analyzed and the correlation of the dietary intake between 24-hour recall and food frequency method to determine the reliability between two methods. Also each nutrient intake was compared to recommended dietary allowance (RDA) or nutrient reference value (NRV) as appropriate. Even correlation did not show significance between the two methods except for dietary fiber intake (0.65 at p<0.01) and energy-yielding nutrients which mostly showed similar results with nutrient intake level. These support the possible reliability between 24-hours record and food frequency method that is also shown on the cases of most mineral and vitamin intakes. Thus, the food frequency method used in this study for the assessment of nutrient intakes of the elderly people would be reliable for the assessment of the nutrient intake along with the 24-hour recall. Also, the present study results suggested that rural female elderly people would be under optimal nutriture status due to the lower food intake measured by 24-hour recall. The optimal food frequency method would be considered to be developed for the precise nutrient assessment.

4-Dimensional dose evaluation using deformable image registration in respiratory gated radiotherapy for lung cancer (폐암의 호흡동조방사선치료 시 변형영상정합을 이용한 4차원 선량평가)

  • Um, Ki Cheon;Yoo, Soon Mi;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.83-95
    • /
    • 2018
  • Purpose : After planning the Respiratory Gated Radiotherapy for Lung cancer, the movement and volume change of sparing normal structures nearby target are not often considered during dose evaluation. This study carried out 4-D dose evaluation which reflects the movement of normal structures at certain phase of Respiratory Gated Radiotherapy, by using Deformable Image Registration that is well used for Adaptive Radiotherapy. Moreover, the study discussed the need of analysis and established some recommendations, regarding the normal structures's movement and volume change due to Patient's breathing pattern during evaluation of treatment plans. Materials and methods : The subjects were taken from 10 lung cancer patients who received Respiratory Gated Radiotherapy. Using Eclipse(Ver 13.6 Varian, USA), the structures seen in the top phase of CT image was equally set via Propagation or Segmentation Wizard menu, and the structure's movement and volume were analyzed by Center-to Center method. Also, image from each phase and the dose distribution were deformed into top phase CT image, for 4-dimensional dose evaluation, via VELOCITY Program. Also, Using $QUASAR^{TM}$ Phantom(Modus Medical Devices) and $GAFCHROMIC^{TM}$ EBT3 Film(Ashland, USA), verification carried out 4-D dose distribution for 4-D gamma pass rate. Result : The movement of the Inspiration and expiration phase was the most significant in axial direction of right lung, as $0.989{\pm}0.34cm$, and was the least significant in lateral direction of spinal cord, as -0.001 cm. The volume of right lung showed the greatest rate of change as 33.5 %. The maximal and minimal difference in PTV Conformity Index and Homogeneity Index between 3-dimensional dose evaluation and 4-dimensional dose evaluation, was 0.076, 0.021 and 0.011, 0.0 respectfully. The difference of 0.0045~2.76 % was determined in normal structures, using 4-D dose evaluation. 4-D gamma pass rate of every patients passed reference of 95 % gamma pass rate. Conclusion : PTV Conformity Index was more significant in all patients using 4-D dose evaluation, but no significant difference was observed between two dose evaluations for Homogeneity Index. 4-D dose distribution was shown more homogeneous dose compared to 3D dose distribution, by considering the movement from breathing which helps to fill out the PTV margin area. There was difference of 0.004~2.76 % in 4D evaluation of normal structure, and there was significant difference between two evaluation methods in all normal structures, except spinal cord. This study shows that normal structures could be underestimated by 3-D dose evaluation. Therefore, 4-D dose evaluation with Deformable Image Registration will be considered when the dose change is expected in normal structures due to patient's breathing pattern. 4-D dose evaluation with Deformable Image Registration is considered to be a more realistic dose evaluation method by reflecting the movement of normal structures from patient's breathing pattern.

  • PDF