• 제목/요약/키워드: Reference phantoms

검색결과 40건 처리시간 0.025초

Iodine-131 S values for use in organ dose estimation of Korean patients in radioiodine therapy

  • Yeom, Yeon Soo;Shin, Bangho;Choi, Chansoo;Han, Haegin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.689-700
    • /
    • 2022
  • In the present study, iodine-131 S values (rT ← thyroid) were calculated for 30 target organs and tissues using the most recently developed Korean reference computational phantoms. The calculated S values were then compared with those of the International Commission on Radiological Protection (ICRP) reference computational phantoms to investigate the dosimetric impact of the Korean S values against those of the ICRP reference phantoms. The results showed significant differences in the S values due to the different anatomical/morphological characteristics between the Korean and ICRP reference phantoms. Most target organs/tissues showed that the S values of the Korean reference phantoms are lower than those of the ICRP reference phantoms, by up to about 4 times (male spleen and female thymus). Exceptionally, three target organs/tissues (gonads, thyroid, and extrathoracic region) showed that the S values of the Korean reference phantoms are greater, by 1.5-3.7 times. We expect that the S values calculated in the present study will be beneficially used to estimate organ/tissue doses of Korean patients under radioiodine therapy.

Korean-specific iodine S values for use in internal dosimetry

  • Tae-Eun Kwon;Yoonsun Chung;Choonsik Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4659-4663
    • /
    • 2023
  • The use of iodine S values derived using the International Commission Radiological Protection (ICRP) phantoms may introduce significant bias in internal dosimetry for Koreans due to anatomical variability. In the current study, we produced an extensive dataset of Korean S values for selected five iodine radioisotopes (I-125, I-129, I131, I-133, and I-134) for use in radiation protection. To calculate S values, we implemented Monte Carlo simulations using the Mesh-type Reference Korean Phantoms (MRKPs), developed in a high-quality/fidelity mesh format. Noticeable differences were observed in S value comparisons between the Korean and ICRP reference phantoms with ratios (Korean/ICRP) widely ranging from 0.16 to 6.2. The majority of S value ratios were lower than the unity in Korean phantoms (interquartile range = 0.47-1.28; mean = 0.96; median = 0.69). The S values provided in the current study will be extensively utilized in iodine internal dosimetry for Koreans.

Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy

  • Soo Min Lee;Chansoo Choi;Ji Won Choi;Chul Hee Min;Seulki Ko;Bangho Shin;Chan Hyeong Kim;Yeon Soo Yeom
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2247-2257
    • /
    • 2024
  • To investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ~120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ~145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatric-specific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients.

Dose coefficients of mesh-type ICRP reference computational phantoms for external exposures of neutrons, protons, and helium ions

  • Yeom, Yeon Soo;Choi, Chansoo;Han, Haegin;Shin, Bangho;Nguyen, Thang Tat;Han, Min Cheol;Kim, Chan Hyeong;Lee, Choonsik
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1545-1556
    • /
    • 2020
  • Recently, the International Commission on Radiological Protection (ICRP) has developed the Mesh-type Reference Computational Phantoms (MRCPs) for adult male and female to overcome the limitations of the current Voxel-type Reference Computational Phantoms (VRCPs) described in ICRP Publication 110 due to the limited voxel resolutions and the nature of voxel geometry. In our previous study, the MRCPs were used to calculate the dose coefficients (DCs) for idealized external exposures of photons and electrons. The present study is an extension of the previous study to include three additional particles (i.e., neutrons, protons, and helium ions) into the DC library by conducting Monte Carlo radiation transport simulations with the Geant4 code. The calculated MRCP DCs were compared with the reference DCs of ICRP Publication 116 which are based on the VRCPs, to appreciate the impact of the new reference phantoms on the DC values. We found that the MRCP DCs of organ/tissue doses and effective doses were generally similar to the ICRP-116 DCs for neutrons, whereas there were significant DC differences up to several orders of magnitude for protons and helium ions due mainly to the improved representation of the detailed anatomical structures in the MRCPs over the VRCPs.

Dose coefficients of mesh-type ICRP reference computational phantoms for idealized external exposures of photons and electrons

  • Yeom, Yeon Soo;Choi, Chansoo;Han, Haegin;Lee, Hanjin;Shin, Bangho;Nguyen, Thang Tat;Han, Min Cheol;Lee, Choonsik;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.843-852
    • /
    • 2019
  • In the present study, we established a comprehensive dataset of dose coefficients (DCs) of the new meshtype ICRP reference computational phantoms (MRCPs) for idealized external exposures of photons and electrons with the Geant4 code. Subsequently, the DCs for the nine organs/tissues, calculated for their thin radiosensitive target regions, were compared with the values calculated by averaging the absorbed doses over the entire organ/tissue regions to observe the influence of the thin sensitive regions on dose calculations. The result showed that the influences for both photons and electrons were generally insignificant for the majority of organs/tissues, but very large for the skin and eye lens, especially for electrons. Furthermore, the large influence for the skin eventually affected the effective dose calculations for electrons. The DCs of the MRCPs also were compared with the current ICRP-116 values produced with the current ICRP-110 reference phantoms. The result showed that the DCs for the majority of organs/ tissues and effective dose were generally similar to the ICRP-116 values for photons, except for very low energies; however, for electrons, significant differences from the ICRP-116 values were found in the DCs, particularly for superficial organs/tissues and skeletal tissues, and also for effective dose.

Reference dosimetry for inter-laboratory comparison on retrospective dosimetry techniques in realistic field irradiation experiment using 192Ir

  • Choi, Yoomi;Kim, Hyoungtaek;Kim, Min Chae;Yu, Hyungjoon;Lee, Hyunseok;Lee, Jeong Tae;Lee, Hanjin;Kim, Young-su;Kim, Han Sung;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2599-2605
    • /
    • 2022
  • The Korea Retrospective Dosimetry network (KREDOS) performed an inter-laboratory comparison to confirm the harmonization and reliability of the results of retrospective dosimetry using mobile phone. The mobile phones were exposed to 192Ir while attached to the human phantoms in the field experiment, and the exposure doses read by each laboratory were compared. This paper describes the reference dosimetry performed to present the reference values for inter-comparison and to obtain additional information about the dose distribution. Reference dosimetry included both measurement using LiF:Mg,Cu,Si and calculation via MCNP simulation to allow a comparison of doses obtained with the two different methodologies. When irradiating the phones, LiF elements were attached to the phones and phantoms and irradiated at the same time. The comparison results for the front of the phantoms were in good agreement, with an average relative difference of about 10%, while an average of about 16% relative difference occurred for the back and side of the phantom. The differences were attributed to the different characteristics of the physical and simulated phantoms, such as anatomical structure and constituent materials. Nevertheless, there was about 4% of under-estimation compared to measurements in the overall linear fitting, indicating the calculations were well matched to the measurements.

Investigation on Individual Variation of Organ Doses for Photon External Exposures: A Monte Carlo Simulation Study

  • Yumi Lee;Ji Won Choi;Lior Braunstein;Choonsik Lee;Yeon Soo Yeom
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.50-64
    • /
    • 2024
  • Background: The reference dose coefficients (DCs) of the International Commission on Radiological Protection (ICRP) have been widely used to estimate organ doses of individuals for risk assessments. This approach has been well accepted because individual anatomy data are usually unavailable, although dosimetric uncertainty exists due to the anatomical difference between the reference phantoms and the individuals. We attempted to quantify the individual variation of organ doses for photon external exposures by calculating and comparing organ DCs for 30 individuals against the ICRP reference DCs. Materials and Methods: We acquired computed tomography images from 30 patients in which eight organs (brain, breasts, liver, lungs, skeleton, skin, stomach, and urinary bladder) were segmented using the ImageJ software to create voxel phantoms. The phantoms were implemented into the Monte Carlo N-Particle 6 (MCNP6) code and then irradiated by broad parallel photon beams (10 keV to 10 MeV) at four directions (antero-posterior, postero-anterior, left-lateral, right-lateral) to calculate organ DCs. Results and Discussion: There was significant variation in organ doses due to the difference in anatomy among the individuals, especially in the kilovoltage region (e.g., <100 keV). For example, the red bone marrow doses at 0.01 MeV varied from 3 to 7 orders of the magnitude depending on the irradiation geometry. In contrast, in the megavoltage region (1-10 MeV), the individual variation of the organ doses was found to be negligibly small (differences <10%). It was also interesting to observe that the organ doses of the ICRP reference phantoms showed good agreement with the mean values of the organ doses among the patients in many cases. Conclusion: The results of this study would be informative to improve insights in individual-specific dosimetry. It should be extended to further studies in terms of many different aspects (e.g., other particles such as neutrons, other exposures such as internal exposures, and a larger number of individuals/patients) in the future.

Organ dose conversion coefficients in CT scans for Korean adult males and females

  • Lee, Choonsik;Won, Tristan;Yeom, Yeon Soo;Griffin, Keith;Lee, Choonik;Kim, Kwang Pyo
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.681-688
    • /
    • 2022
  • Dose monitoring in CT patients requires accurate dose estimation but most of the CT dose calculation tools are based on Caucasian computational phantoms. We established a library of organ dose conversion coefficients for Korean adults by using four Korean adult male and two female voxel phantoms combined with Monte Carlo simulation techniques. We calculated organ dose conversion coefficients for head, chest, abdomen and pelvis, and chest-abdomen-pelvis scans, and compared the results with the existing data calculated from Caucasian phantoms. We derived representative organ doses for Korean adults using Korean CT dose surveys combined with the dose conversion coefficients. The organ dose conversion coefficients from the Korean adult phantoms were slightly greater than those of the ICRP reference phantoms: up to 13% for the brain doses in head scans and up to 10% for the dose to the small intestine wall in abdominal scans. We derived Korean representative doses to major organs in head, chest, and AP scans using mean CTDIvol values extracted from the Korean nationwide surveys conducted in 2008 and 2017. The Korean-specific organ dose conversion coefficients should be useful to readily estimate organ absorbed doses for Korean adult male and female patients undergoing CT scans.

웹 기반 표준한국인 장기 흡수선량 및 유효선량 평가 시스템 개발 (Development of Reference Korean Organ and Effective Dose Calculation Online System)

  • 박수연;염연수;김재현;이현수;한민철;정종휘;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.30-37
    • /
    • 2014
  • 최근 표준한국인 성인남녀 복셀 팬텀 한 쌍인 High-Definition Reference Korean-Man (HDRK-Man)과 High-Definition Reference Korean-Woman (HDRK-Woman)을 개발한 바 있다. HDRK-Man과 HDRK-Woman은 각각 한국인 성인 남성과 여성을 대표하므로 이들을 이용하면 한국인 고유의 유효선량을 계산할 수 있다. 이러한 한국인 고유의 유효선량을 계산하기 위해서는 표준한국인 팬텀을 이용한 몬테칼로 선량계산을 수행하여야 한다. 하지만 이러한 몬테칼로 선량계산은 전산인체모델에 대한 이해와 고도의 몬테칼로 전산모사 기술이 요구되기 때문에 몬테칼로 전산모사 경험이 적은 연구자들에게는 접근성이 용이하지 않다. 최근 UFPE (Federal University of Pernambuco) 연구팀에서는 몬테칼로 선량계산 온라인 시스템인 CALDOSE_X를 운영하고 있다. CALDOSE_X는 사용자가 온라인상에서 직접 입력한 선원조건에 따라 곧바로 몬테칼로 선량계산을 수행하고 계산된 결과를 제공해주는 온라인 서비스이다. 따라서 CALDOSE_X를 이용하면 몬테칼로 전산모사 경험 없이도 누구나 쉽게 원하는 선원조건에 대한 선량계산을 수행할 수 있다. 하지만 CALDOSE_X에서 제공하는 선량값은 서양인 전산팬텀을 이용하기 때문에, 이를 한국인 종사자에 대한 방사선 방호목적으로 사용하기에는 여전히 한계가 있다. 이에 본 연구에서는 온라인상에서 사용자가 입력한 선원조건에 따라 실시간으로 표준 한국인에 대한 유효선량을 계산할 수 있는 웹 기반 표준한국인 선량평가 시스템을 구축하였다.

Organ Dose Conversion Coefficients Calculated for Korean Pediatric and Adult Voxel Phantoms Exposed to External Photon Fields

  • Lee, Choonsik;Yeom, Yeon Soo;Griffin, Keith;Lee, Choonik;Lee, Ae-Kyoung;Choi, Hyung-do
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.69-75
    • /
    • 2020
  • Background: Dose conversion coefficients (DCCs) have been commonly used to estimate radiation-dose absorption by human organs based on physical measurements of fluence or kerma. The International Commission on Radiological Protection (ICRP) has reported a library of DCCs, but few studies have been conducted on their applicability to non-Caucasian populations. In the present study, we collected a total of 8 Korean pediatric and adult voxel phantoms to calculate the organ DCCs for idealized external photon-irradiation geometries. Materials and Methods: We adopted one pediatric female phantom (ETRI Child), two adult female phantoms (KORWOMAN and HDRK Female), and five adult male phantoms (KORMAN, ETRI Man, KTMAN1, KTMAN2, and HDRK Man). A general-purpose Monte Carlo radiation transport code, MCNPX2.7 (Monte Carlo N-Particle Transport extended version 2.7), was employed to calculate the DCCs for 13 major radiosensitive organs in six irradiation geometries (anteroposterior, posteroanterior, right lateral, left lateral, rotational, and isotropic) and 33 photon energy bins (0.01-20 MeV). Results and Discussion: The DCCs for major radiosensitive organs (e.g., lungs and colon) in anteroposterior geometry agreed reasonably well across the 8 Korean phantoms, whereas those for deep-seated organs (e.g., gonads) varied significantly. The DCCs of the child phantom were greater than those of the adult phantoms. A comparison with the ICRP Publication 116 data showed reasonable agreements with the Korean phantom-based data. The variations in organ DCCs were well explained using the distribution of organ depths from the phantom surface. Conclusion: A library of dose conversion coefficients for major radiosensitive organs in a series of pediatric and adult Korean voxel phantoms was established and compared with the reference data from the ICRP. This comparison showed that our Korean phantom-based data agrees reasonably with the ICRP reference data.