• Title/Summary/Keyword: Reference coordinate system

Search Result 193, Processing Time 0.027 seconds

PACS based Digital Stereostactic Surgery Planing System (PACS 기반의 디지털 뇌정위 수술 계획 시스템)

  • Lee, Dong-Hyuk;Kim, Jong-Hyo;Oh, Chang-Wan;Kim, Soo-Jeong;Min, Byung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.206-209
    • /
    • 1997
  • The stereostatic surgery becomes a important part of neurosurgery. The conventional style of stereostatic system uses a input method of film digitizing. It is time consuming and laborious. In this paper, we presented a system that can manage digital images from medical imaging machine to surgery assisting program. CT images were transferred in DICOM format to a surgery assisting computer in a operation room through PACS. The streotatic surgery assisting program processed the digital images and calculated the parameters that were required in steostatic surgery. The assisting program were developed that can detect the reference points automatically, transform CT coordinate to frame coordinate and calculate the RM (Riechert-Mundinger) frame. This system were applied to clinical cases in Seoul National Univ. Hospital. The two advantages of this system were revealed. The processing time from imaging to surgery parameters were much aster than conventional system. The surgery accuracy were more mininute as the digitizing error were reduced. This system were a good application of connecting imaging machines to clinical treatment system through PACS.

  • PDF

Stereo Vision System Using Relative Stereo Disparity with Subpixel Resolution

  • Kim, Chi-Yen;Ahn, Cheol-Ki;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.407-407
    • /
    • 2000
  • For acquisition of 3-Dimensional information in real space, stereo vision system is suitable. In the stereo system, 3D real world position is derived from translation of coordinates between cameras and world. Thus, to use stereo vision, it is needed to construct a precise system which provides kinematically precise translation between camera and world coordinate, in spite of intricacy and hardness. So much cost and time should be spent to build the system. In this paper, facilely to solve previous problem, a method which can easily obtain 3D informations using reference objects and RSD(Relative Stereo Disparity) is proposed. Instead of direct computation of position with translation of coordinates, only relative stereo disparity in stereo pair of image is used to find the reference depth of objects, and real 3D position is computed with initial condition of reference objects. In computation, subpixel resolution is involved to find the display for accuracy. To find the RSD, corresponding points are calculated in subpixel resolution. So the result in experiemnt will be shown that subpixel resolution is more accurate than 1 pixel resolution.

  • PDF

Nonlinear control of unicycle-type mobile robot (Unicycle-type 이동로봇의 비선형 제어)

  • 김용진;문인혁
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.131-134
    • /
    • 2001
  • This paper proposes a stable control rule for nonlinear unicycle-type mobile robot. The control method uses a local error coordinate system, velocity and distance constants $\kappa$$\_$x/, $\kappa$$\_$y/, and he. Stability of control rule is proved Liapunov function. System input to the mobile robot is reference posture ($\chi$$\_$r/, y$\_$r/, $\theta$$\_$r/)/sup/ $\tau$/ and reference e velocity (ν$\_$r/,$\omega$$\_$r/)$\^$$\tau$/. System output of the mobi-le robot is velocity of driving wheels. We introduce limit velocity for preventing high initial speed. From simulation results, we can see the proposed control rule is stable.

  • PDF

Development of Spatial Reference System Component with Open GIS Simple Features Specification (개방형 GIS의 단순개체 사양을 이용한 공간 기준 좌표계 컴포넌트의 개발)

  • Lee, Dae-Hee;Biun, Su-Yun;Lim, Sam-Sung
    • Journal of Korea Spatial Information System Society
    • /
    • v.2 no.1 s.3
    • /
    • pp.57-62
    • /
    • 2000
  • Open GIS Consortium(OGC) provides with Simple Features Specification for OLE/COM which is a system object technology of interoperability and reusable capability. In this research, the Spatial Reference System(SRS) component is developed based on the OGC specification using ATL. The component presents 44 map projections and transformations between different geographic coordinate systems utilizing the seven parameter(Bursa Wolf) and Molodenski's methods, a user can set up all objects and its attributes comprising SRS and can create SRS and save its setting using predefined text, WellKnownText. The Spatial Reference System component can be easily implemented into the variety of GIS software so that it reduces the developing time for a system and defines new reference system without difficulty.

  • PDF

Measurement and Algorithm Calculation of Maxillary Positioning Change by Use of an Optoelectronic Tracking System Marker in Orthognathic Surgery (악교정수술에서 광전자 포인트 마커를 이용한 상악골 위치 변화의 계측 및 계산 방법 연구)

  • Park, Jong-Woong;Kim, Soung-Min;Eo, Mi-Young;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.233-240
    • /
    • 2011
  • Purpose: To apply a computer assisted navigation system to orthognathic surgery, a simple and efficient measuring algorithm calculation based on affine transformation was designed. A method of improving accuracy and reducing errors in orthognathic surgery by use of an optical tracking camera was studied. Methods: A total of 5 points on one surgical splint were measured and tracked by the Polaris $Vicra^{(R)}$ (Northern Digital Inc Co., Ontario, Canada) optical tracking system in two cases. The first case was to apply the transformation matrix at pre- and postoperative situations, and the second case was to apply an affine transformation only after the postoperative situation. In each situation, the predictive measuring value was changed to the final measuring value via an affine transformation algorithm and the expected coordinates calculated from the model were compared with those of the patient in the operation room. Results: The mean measuring error was $1.027{\pm}0.587$ using the affine transformation at pre- and postoperative situations and the average value after the postoperative situation was $0.928{\pm}0.549$. The farther a coordinate region was from the reference coordinates which constitutes the transform matrixes, the bigger the measuring error was found which was calculated from an affine transformation algorithm. Conclusion: Most difference errors were brought from mainly measuring process and lack of reproducibility, the affine transformation algorithm formula from postoperative measuring values by using of optic tracking system between those of model surgery and those of patient surgery can be selected as minimizing the difference error. To reduce coordinate calculation errors, minimum transformation matrices must be used and reference points which determine an affine transformation must be close to the area where coordinates are measured and calculated, as well as the reference points need to be scattered.

A Comparative Analysis of 3D Circle Fitting Algorithms for Determination of VLBI Antenna Reference Point (VLBI 안테나 기준점 결정을 위한 3D Circle Fitting 알고리즘의 비교 분석)

  • Hyuk Gil, Kim;Jin Sang, Hwang;Hong Sik, Yun;Tae Jun, Jeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.4
    • /
    • pp.231-244
    • /
    • 2015
  • The accuracy of reference point of VLBI antenna is mandatory to perform collocation of different space geodetic techniques. In this study, we evaluated the optimal methods for the 3D circle fitting to enhance the accuracy of the reference point of VLBI antenna. Two kinds of methodologies for the orthonormal coordinate system with translation of planar observation point and the unitary coordinate transforamation were suggested and their fitting accuracies were evaluated where the orthogonal distance was calculated by residual between observation point and fitting model and the recursive calculation was performed to improve the accuracy of 3D circle fitting. Finally, we found that the methodology for the unitary coordinate transformation is highly appropriate to determine the optimal equation for azimuth-axis and elevation-axis of VLBI antenna. Therefore, the reference point of VLBI antenna with high accuracy can be determined by the intersection of the above two axises (azimuth-axis and elevation-axis). This result is expected to be utilized for a variety of researches for connection between VLBI observation results and the national control point.

Improved DC Offset Error Compensation Algorithm in Phase Locked Loop System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1707-1713
    • /
    • 2016
  • This paper proposes a dc error compensation algorithm using dq-synchronous coordinate transform digital phase-locked-loop in single-phase grid-connected converters. The dc errors are caused by analog to digital conversion and grid voltage during measurement. If the dc offset error is included in the phase-locked-loop system, it can cause distortion in the grid angle estimation with phase-locked-loop. Accordingly, recent study has dealt with the integral technique using the synchronous reference frame phase-locked-loop method. However, dynamic response is slow because it requires to monitor one period of grid voltage. In this paper, the dc offset error compensation algorithm of the improved response characteristic is proposed by using the synchronous reference frame phase-locked-loop. The simulation and the experimental results are presented to demonstrate the effectiveness of the proposed dc offset error compensation algorithm.

Calibration/Compensation of Errors of the Touch Probe (접촉식 프로브의 오차교정 및 보정기술)

  • 박희재;이교일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2081-2087
    • /
    • 1994
  • Touch trigger probes are widely used for inspection purposed in the CMM(Coordinate meauring machine) or machine tool. The errors introduced by measurement probe are fairy systematic, thus can be calibrated and compensated properly. This paper presents a technique for the error calibration and compensation of the probe errors, which can be easily applicable to the manufacturers and users of the measurement probe. The probe coordinate system is defined for the probe error assessment, and a reference sphere ball is measured, and the probe errors are calibrated. The calibrated probe errors are represented in the 3D error map and 2D error map along probing direction. Detail algorithms for the error compensation are proposed.

An investigation of normal range of tongue color in numerical coordinate (정상 설색의 수치적 기준에 관한 고찰)

  • Kim, Changhee;Kim, Kiwang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.3
    • /
    • pp.215-223
    • /
    • 2013
  • Objectives Although tongue diagnosis is one of major diagnostic methods in east Asian traditional medicine, the standard of normal tongue color have not established. So we tried to suggest the method to establish the standard of normal tongue color range and the pilot data about the normal range. Materials and methods: 22 precedent study papers that presented the numerical data of normal (light red) tongue color were analyzed. At the same time, 46 adult people tongue color data were also collected and analyzed. Results Precedent studies showed remarkable fluctuations of the range of normal tongue color. Collected tongue color data of the 46 people showed mean Hue value 2 and standard deviation 14 in HSB system. Additionally, 3 ways of standard establishment for normal tongue color were suggested. Conclusion We suggest statistical method as a reasonable method for tongue color standard establishment and $2{\pm}14$ as a reference Hue value for normal tongue color.

Elastic Wave Propagation in Monoclinic System Due to Harmonic Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.47-52
    • /
    • 1998
  • An analysis of dynamic responses is carried out on monoclinic anisotropic system due to a buried harmonic line source. The load is in the form of a normal stress acting along an arbitrary axis on the plane of symmetry within the orthotropic materials: In case that the line load is acting along the symmetry axis normal to the plane of symmetry, plane wave equation is coupled with verital shear wave and longitudinal wave. However, if the line load is acting along an arbitrary axis normal to the plane of symmetry, plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in a reference coordinate system, where the line load is coincident with a symmetry axis of the orthotropic material. Then the equation of motion is transformed into one with respect to general coordinate system with azimuthal angle by using transformation tensor. Plane wave solutions of monoclinic systems are derived for infinite media. Finally complete solutions for the plane harmonic wave are obtained by calculating the inverse of the integral transforms, in which bulk wave poles are avoided by deforming the contour of the integration to the complex plane. Numerical results for examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF