• 제목/요약/키워드: Reference condition

검색결과 1,262건 처리시간 0.023초

The Suggestion of Effective Measurement Techniques for Positioning Under Poor GPS Reference Network Condition

  • Park, Joon-Kyu;Jung, Kap-Yong
    • 한국측량학회지
    • /
    • 제31권6_2호
    • /
    • pp.539-547
    • /
    • 2013
  • This research is suggesting the most effective positioning method for GPS based positioning when no GPS reference point is available in the neighborhood. For this purpose, we carried out positioning of the IGS realtime observatories in Australia in various conditions. According to the research, we were certainly assured the one reference point with a short baseline length is more effective for differential positioning than multiple reference points with a long baseline distance beyond 1,000km and suggested the precise point positioning based positioning method can be an excellent substitute when no reference point is available around an unknown point. The research result may be used as the basic data for accurate positioning in poor reference point environments, especially in Antarctica.

기준 슬립 발생기 및 적응 슬라이딩 모드 기법을 이용한 철도차량 제동력 제어 (Adhesive Force Control of Railway Rolling Stock Using Reference Slip Generator and Adaptive Sliding-mode Technique)

  • 임태형;김승수;최정주;이병룡;양순용
    • 한국정밀공학회지
    • /
    • 제24권5호
    • /
    • pp.56-61
    • /
    • 2007
  • In the braking of railway rolling stock, the slip that is the relative velocity between train body and its wheel affects the adhesive force which is connected to the braking force. The coefficient of the adhesive force changes in accordance with the slip and the condition of a rail road. Namely, its value increases upon the maximum on a rail condition, and there it declines conversely while the magnitude of slip keeps rising on. First, this paper introduced a reference slip generator so that can utilize maximum adhesive forces with a disturbance observer for estimating unmeasurable current adhesive forces which is as an input of the generator. And, an adaptive sliding-mode control system has been synthesized for minimizing the error between reference and current slip. Finally the effectiveness of the proposed control system is evaluated by computer simulation.

The Excitability by Both Electric and Concentrative Perturbation in CSTR

  • Bae, Jeong Min;Cho, Ung In
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권8호
    • /
    • pp.1145-1148
    • /
    • 2006
  • Excitability is one of the basic and fundamental mechanisms utilized for signal transmission in living organisms. With reference to the condition by Marek and the condition by Schneider, we found a condition in which excitability with similar shapes can appear by chemical and electric perturbation. Our condition is constructed with 3 chemical channels and 1 electric channel, and can be used as a condition for a chemical spiking neuron and as a unit of a chemical spiking neural network.

Diagnostic Technique for Cast Resin Molded Transformer Windings Using Active Thermography

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.376-380
    • /
    • 2006
  • Temperature distribution measured to estimate the condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current temperature. Because of passive thermography, without the external thermal stimulation, the difference in surface temperature between the region of interest and back ground shows that the results can apply only to the estimation or the monitoring for the condition of loose terminal and the overload pertaining to the rise in temperature. However, a thermal diffusion in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents a nondestructive test using this behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

열화상을 이용한 몰드변압기 권선표면 진단 (Diagnostic Technique for Mold Transformer Windings using Thermal Image)

  • 임용배;정종욱;정진수;고원식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.107-109
    • /
    • 2005
  • Temperature distribution measured to estimate condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current one. Because a passive thermography without the external thermal stimulation shows the difference in surface temperature between the object and back ground, the results can apply only to the estimation or the monitoring for the condition of terminal loose and the overload pertaining to the rise in temperature. However, a thermal flow in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents the nondestructive testing using the behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

Condition assessment of steel shear walls with tapered links under various loadings

  • He, Liusheng;Kurata, Masahiro;Nakashima, Masayoshi
    • Earthquakes and Structures
    • /
    • 제9권4호
    • /
    • pp.767-788
    • /
    • 2015
  • A steel shear wall with double-tapered links and in-plane reference was developed for assisting the assessment of the structural condition of a building after an earthquake while maintaining the original role of the wall as a passive damper device. The double-tapered link subjected to in-plane shear deformation is designed to deform torsionally after the onset of local buckling and works as an indicator of the maximum shear deformation sustained by the shear wall during an earthquake. This paper first examines the effectiveness of double-tapered links in the assessment of the structural condition under various types of loading. A design procedure using a baseline incremental two-cycle loading protocol is verified numerically and experimentally. Meanwhile, in-plane reference links are introduced to double-tapered links and greatly enhance objectivity in the inspection of notable torsional deformation with the naked eye. Finally, a double-layer system, which consists of a layer with double-tapered links and a layer with rectangular links made of low-yield-point steel, is tested to demonstrate the feasibility of realizing both structural condition assessment and enhanced energy dissipation.

공동주택 자재표준화를 위한 조립기준면 설계기준에 관한 연구 (A Study on the Design Guideline based Reference Plane for Standardization in Material of the Multi-family housing)

  • 박근수;임석호;지장훈
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.241-244
    • /
    • 2008
  • This study focused on the checking of design guideline using concept of reference plane as a promoting tool in order to apply to practical affair in relation to material standardization in housing build. For this purpose, we above all defined the role of reference plane. After establishing structural type can correspond to planning module of building components and coordination condition, we did exemplicated the sub-detail of building components which be to detach according to design method using the concept of reference plane that be complexed with spacial territory and replace cycle of building component or material.

  • PDF

다중 참조 영상 움직임 추정을 위한 고속 전역탐색법 (A fast full search algorithm for multiple reference image motion estimation)

  • 강현수;박성모
    • 대한전자공학회논문지SP
    • /
    • 제43권1호
    • /
    • pp.1-8
    • /
    • 2006
  • 본 논문은 다중 참조영상(multiple reference image)에 적용 가능한 새로운 고속 전역탐색 움직임 추정 기법을 제안한다. 제안된 방법은 기존의 비트율을 고려한 연속제거알고리즘(rate constrained successive elimination algorithm: RSEA)을 다중 참조영상에 확대 적용하는 방법이다. 첫 번째 참조영상에 대한 움직임 추정의 계산량에 비해 그 이후 참조영상에 대한 움직임 추정의 계산량이 적어질 수 있음을 보일 것이다. 계산량 감축을 위해, 본 논문에서 최적 움직임 벡터의 후보 블록의 개수를 감소시킬 수 있는 새로운 조건을 소개한다. 실험 결과을 통해 제안된 방법이 기존의 RSEA과 동일한 움직임 추정오차를 가지면서도 계산량을 감소시킴을 보일 것이다.

광범위 크리프 조건에 대한 관통균열 배관의 크리프 파괴역학 해석 (Creep Fracture Mechanics Analysis for Through-Wall Cracked Pipes under Widespread Creep Condition)

  • 허남수;김윤재;김영진
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.890-897
    • /
    • 2003
  • This paper compares engineering estimation schemes of C* and creep COD for circumferential and axial through-wall cracked pipes at elevated temperatures with detailed 3-D elastic-creep finite element results. Engineering estimation schemes included the GE/EPRI method, the reference stress method where reference stress is defined based on the plastic limit load and the enhanced reference stress method where the reference stress is defined based on the optimized reference load. Systematic investigations are made not only on the effect of creep-deformation behaviour on C* and creep COD, but also on effects of the crack location, the pipe geometry, the crack length and the loading mode. Comparison of the FE results with engineering estimations provides that for idealized power law creep, estimated C* and COD rate results from the GE/EPRI method agree best with FE results. For general creep-deformation laws where either primary or tertiary creep is important and thus the GE/EPRI method is hard to apply, on the other hand, the enhanced reference stress method provides more accurate and robust estimations for C* and COD rate than the reference stress method.

주거단지 건설이 하천에 미치는 생태영향평가 (Environmental Impact Assessments along with Construction of Residential and Commercial Complex)

  • 안광국;한정호;이재훈
    • 환경영향평가
    • /
    • 제21권5호
    • /
    • pp.631-648
    • /
    • 2012
  • The integrative ecological approaches of chemical assessments, physical habitat modelling, and multi-metric biological health modelling were applied to Gwanpyeong Stream within Gap-Stream watersheds to evaluate environmental impacts on the constructions of residential and commercial complex. For the analysis, the surveys conducted from 45 sites of reference streams within the Gap-Stream watershed and 3 regular sites during 2009 - 2010. Physical habitat health, based on the habitat model of Qualitative Habitat Evaluation Index(QHEI) declined from the headwaters(good - fair condition) to the downstream(poor condition). Chemical water quality, based turbidity and electric conductivity(EC), was degraded toward to the downstream, and especially showed abrupt increases, compared to the values of control streams(CS). Also, concentrations of chlorophyll-a in the downstreams were greater compared to the control stream(CS), indicating an eutrophication. Biological health conditions, based on the Index of Biological Integrity(IBI) using fish assemblages, averaged 19.3 which is judged as a fair condition by the biological criteria of the Ministry of Environment, Korea. The comparisons of model metric values in sensitive species and riffle-benthic species on the Maximum Species Richness Line(MSRL) of 45 reference streams indicated a massive disturbances in all sampling locations. Also, tolerance guild and trophic guild analyses suggest that dominances of tolerant species and omnivores were evident, indicating a biological degradation by habitat disturbances and organic matter pollutions. There was no distinct longitudinal variations of IBI model values from the headwater to the downstream in spite of slight chemical and habitat health gradients among the sampling sites. Overall, integrative ecological health(IEH) scores, based on the chemical, physical, and biological parameters, were low compared to the 45 reference streams due to physical and chemical disturbances of massive constructions of the residential and commercial complex. This stream, thus showed a tendency of typical urban streams which are disturbed in the chemical water quality, habitat structures, and biological integrity. Effective stream management plans and restoration strategies are required in this urban stream for improving integrative stream health.