• 제목/요약/키워드: Reference Observations

검색결과 190건 처리시간 0.026초

Swarm Satellite Observations of the 21 August 2017 Solar Eclipse

  • Hussien, Fayrouz;Ghamry, Essam;Fathy, Adel;Mahrous, Salah
    • Journal of Astronomy and Space Sciences
    • /
    • 제37권1호
    • /
    • pp.29-34
    • /
    • 2020
  • On 21 August 2017, during 16:49 UT and 20:02 UT period, a total solar eclipse started. The totality shadow occurred over the United States in time between ~17:15 UT and ~18:47 UT. When the solar radiation is blocked by the moon, observations of the ionospheric parameters will be important in the space weather community. Fortunately, during this eclipse, two Swarm satellites (A and C) flied at about 445 km through lunar penumbra at local noon of United States in the upper ionosphere. In this work, we investigate the effect of the solar eclipse on electron density, slant total electron content (STEC) and electron temperature using data from Swarm mission over United States. We use calibrated measurements of plasma density and electron temperature. Our results indicate that: (1) the electron density and STEC have a significant depletion associated with the eclipse; which could be due to dominance of dissociative recombination over photoionization caused by the reduction of ionizing extreme ultraviolet (EUV) radiation during the eclipse time (2) the electron temperature decreases, compared with a reference day, by up to ~150 K; which could be due to the decrease in photoelectron heating from reduced photoionization.

해안지역 내 원거리 레이더관측자료의 보정에 관한 연구 (Radar Data Correction for Long Distance Observation In Coastal Zone)

  • Ricardo S. TENORIO;Byung-Hyuk Kwon;Hong-Joo Yoon;Dong-In Lee
    • 한국정보통신학회논문지
    • /
    • 제4권5호
    • /
    • pp.985-996
    • /
    • 2000
  • 해안 지역에서 해양으로부터 들어오는 중규모 정도의 강수는 단기 예보를 위하여 원격 탐사에 의한 실시간 관측이 이루어져야 한다. 그러나 위성 관측은 강수를 상세히 묘사하지 못하기 때문에 레이더를 이용한 원거리관측이 요구된다. 본 연구에서는 레이더로 관측된 자료가 강수역을 정확하게 정량화 할 수 있도록 원거리 관측자료의 보정을 논의한다. 반사도의 연직 변화에 기인한 오차는 평균 분포나 통계적 방법으로 그리고 반사도의 감쇠 효과는 반복 편광법으로 보정될 수 있다. 이 같은 다양한 보정을 통하여 레이더로 관측된 원거리 자료를 유용화할 수 있다.

  • PDF

Pi2 Pulsations During Extremely Quiet Geomagnetic Condition: Van Allen Probe Observations

  • Ghamry, Essam
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권2호
    • /
    • pp.111-118
    • /
    • 2017
  • A ultra low frequency (ULF) wave, Pi2, has been reported to occur during periods of extremely quiet magnetospheric and solar wind conditions. And no statistical study on the Pi2 has been performed during extremely quiet conditions, using satellite observations to the author's knowledge. Also Pi2 pulsations in the space fluxgate magnetometers near perigee failed to attract scientist's attention previously. In this paper, Pi2 pulsations detected by the Van Allen probe satellites (VAP-A & VAP-B) were investigated statistically. During the period from October 2012 to December 2014, ninety six Pi2 events were identified using VAP when Kp = 0 while using Kakioka (KAK, L = 1.23) as a reference ground station. Seventy five events had high coherence between VAP-Bz and H components at KAK station. As a result, it was found that 77 % of the events had power spectra between 5 and 12 mHz, which differs from the regular Pi2 band range of from 6.7 to 25 mHz. In addition, it was shown that it is possible to observe Pi2 pulsations from space fluxgate magnetometers near perigee. Twenty two clean Pi2 pulsations were found where L < 4 and four examples of Pi2 oscillations at different L shells are presented in this paper.

The centroid shift of Sgr A*

  • Cho, Il-Je;Sohn, Bong Won;Jung, Taehyun;Kino, Motoki;Zhao, Guang-Yao;Agudo, Ivan;Rioja, Maria;Dodson, Richard
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.41.1-41.1
    • /
    • 2016
  • The Galactic center, Sagittarius A* (Sgr A*), is the closest supermassive black hole and emits synchrotron radiation. It provides great opportunity to study the origin of mm/sub-mm emission. Currently, two competing models have been suggested as a jet base and a radiatively inecient accretion flow (RIAF). To unveil the properties, the extremely high resolution(${\sim}10{\mu}as$) corresponding to the projected Schwarzschild radius of ~0.1AU is necessary. With KVN, a jet model can be tested by multi- frequency simultaneous observations because the optically thick surface in a jet (i.e. radio core) moves toward the center at a higher frequency. We conducted 8 observations with KVN at 43/86GHz in 2015, and found that the measured positional shift to the reference calibrator, J1744-3116, was ~0.3 mas to the south of Sgr A* using the source frequency phase referencing (SFPR) at Q/W bands for the first time. With the result, in the future, we will attempt to measure the variation of source position shifts that can constrain the direction of approaching jets and the variability of black hole activity of Sgr A*.

  • PDF

Multi-Dimension Scaling as an exploratory tool in the analysis of an immersed membrane bioreactor

  • Bick, A.;Yang, F.;Shandalov, S.;Raveh, A.;Oron, G.
    • Membrane and Water Treatment
    • /
    • 제2권2호
    • /
    • pp.105-119
    • /
    • 2011
  • This study presents the tests of an Immersed Membrane BioReactor (IMBR) equipped with a draft tube and focuses on the influence of hydrodynamic conditions on membrane fouling in a pilot-scale using a hollow fiber membrane module of ZW-10 under ambient conditions. In this system, the cross-flow velocities across the membrane surface were induced by a cylindrical draft-tube. The relationship between cross-flow velocity and aeration strength and the influence of the cross-flow on fouling rate (under various hydrodynamic conditions) were investigated using Multi-Dimension Scaling (MDS) analysis. MDS technique is especially suitable for samples with many variables and has relatively few observations, as the data about Membrane Bio-Reactor (MBR) often is. Observations and variables are analyzed simultaneously. According to the results, a specialized form of MDS, CoPlot enables presentation of the results in a two dimensional space and when plotting variables ratio (output/input) rather than original data the efficient units can be visualized clearly. The results indicate that: (i) aeration plays an important role in IMBR performance; (ii) implementing the MDS approach with reference to the variables ratio is consequently useful to characterize performance changes for data classification.

Histological classification of canine ovarian cyst types with reference to medical history

  • Knauf, Yvonne;Kohler, Kernt;Knauf, Sascha;Wehrend, Axel
    • Journal of Veterinary Science
    • /
    • 제19권6호
    • /
    • pp.725-734
    • /
    • 2018
  • Ovaries of 21 bitches presented with gynecopathies were surgically removed and histologically examined. Standard histological, as well as immunohistochemical, classification of 193 cystic structures resulted in the classification of 72 cysts of subsurface epithelial structures (SES), 61 follicular cysts (FCs), 38 cystic rete ovarii (CRO), 13 lutein cysts (LCs), and 9 non-classifiable cysts (NCCs). In addition to the histological classification, results were interpreted according to subject medical history, clinical examination outcome, and macroscopic observations during ovariohysterectomy. Dogs with ovarian cysts (OCs) and associated reproductive perturbations were mostly nulliparous, of large breed, and had an average of $9.5{\pm}3$ years. Prolonged or shortened inter-estrus intervals of past heats, however, seemed to be relatively low-risk factors for the development of OCs in dogs. Furthermore, we provide histological observations of a rarely seen canine LC including a degenerated oocyte in the central cavity.

Ranking Candidate Genes for the Biomarker Development in a Cancer Diagnostics

  • Kim, In-Young;Lee, Sun-Ho;Rha, Sun-Young;Kim, Byung-Soo
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2004년도 The 3rd Annual Conference for The Korean Society for Bioinformatics Association of Asian Societies for Bioinformatics 2004 Symposium
    • /
    • pp.272-278
    • /
    • 2004
  • Recently, Pepe et al. (2003) employed the receiver operating characteristic (ROC) approach to rank candidate genes from a microarray experiment that can be used for the biomarker development with the ultimate purpose of the population screening of a cancer, In the cancer microarray experiment based on n patients the researcher often wants to compare the tumor tissue with the normal tissue within the same individual using a common reference RNA. This design is referred to as a reference design or an indirect design. Ideally, this experiment produces n pairs of microarray data, where each pair consists of two sets of microarray data resulting from reference versus normal tissue and reference versus tumor tissue hybridizations. However, for certain individuals either normal tissue or tumor tissue is not large enough for the experimenter to extract enough RNA for conducting the microarray experiment, hence there are missing values either in the normal or tumor tissue data. Practically, we have $n_1$ pairs of complete observations, $n_2$ 'normal only' and $n_3$ 'tumor only' data for the microarray experiment with n patients, where n=$n_1$+$n_2$+$n_3$. We refer to this data set as a mixed data set, as it contains a mix of fully observed and partially observed pair data. This mixed data set was actually observed in the microarray experiment based on human tissues, where human tissues were obtained during the surgical operations of cancer patients. Pepe et al. (2003) provide the rationale of using ROC approach based on two independent samples for ranking candidate gene instead of using t or Mann -Whitney statistics. We first modify ROC approach of ranking genes to a paired data set and further extend it to a mixed data set by taking a weighted average of two ROC values obtained by the paired data set and two independent data sets.

  • PDF

Pharmacokinetics and Bioequivalence of Haloperidol Tablet by Liquid Chromatographic Mass Spectrometry with Electrospray Ionization

  • Yun Min-Hyuk;Kwon Jun-Tack;Kwon Kwang-il
    • Archives of Pharmacal Research
    • /
    • 제28권4호
    • /
    • pp.488-492
    • /
    • 2005
  • The purpose of this study is to investigate the bioequivalence of two haloperidol 5 mg tablets, Myung In haloperidol (Myung In Pharm. Co., Ltd., test drug) and $Peridol^{R}$(Whanin Pharm. Co., Ltd., reference drug), and also to estimate the pharmacokinetic parameters of haloperidol in Korean volunteers. The bioavailability and pharmacokinetics of haloperidol tablets were examined on 24 healthy volunteers who received a single oral dose of each preparation in the fasting state in a randomized balanced 2 way crossover design. After an oral dosing, blood samples were collected for a period of 60 h. Plasma concentrations of haloperidol were determined using a liquid chromatographic electrospray mass spectrometric (LC-MS) method. The pharmacokinetic parameters were calculated with noncompartmental pharmacokinetic analysis. The geometric means of $AUC_{0-60h} and C_{max}$ between test and reference formulations were $17.21\pm8.26 ng\cdot/mL vs 17.31\pm13.24 ng\cdot/mL and 0.87\pm0.74 ng/mL vs 0.85\pm0.62 ng/mL$. respectively. The $90\%$ confidence intervals of mean difference of logarithmic transformed $AUC_{0-60h} and C_{max} were log0.9677{\sim}log1.1201 and log0.8208{\sim}log1.1981$, respectively. It shows that the bioavailability of test drug is equivalent with that of reference drug. The geometric means of other pharmacokinetic parameters ($AUC_{inf}. t_{1/2}, V_{d}/F, and CL/F$) between test drug and reference drug were $21.75\pm8.50 ng{\cdot}h/mL vs 21.77\pm15.63 ng{\cdot}h/mL, 29.87\pm8.25 h vs 29.60\pm7.56 h, 11.51\pm5.45 L vs 12.90\pm6.12 L and 0.26\pm0.09 L/h vs 0.31\pm0.17 L/h$, respectively. These observations indicate that the two formulation for haloperidol was bioequivalent and, thus, may be clinically interchangeable.

Using the Crab Nebula as Polarization Angle Calibrator for the Korean VLBI Network

  • Minchul Kam;Sascha Trippe;Do-Young Byun;Jongho Park;Sincheol Kang;Naeun Shin;Sang-Sung Lee;Taehyun Jung
    • 천문학회지
    • /
    • 제56권1호
    • /
    • pp.1-9
    • /
    • 2023
  • The Crab nebula is widely used as a polarization angle calibrator for single-dish radio observations because of its brightness, high degree of linear polarization, and well-known polarization angle over a wide frequency range. However, the Crab nebula cannot be directly used as a polarization angle calibrator for single-dish observations with the Korean VLBI Network (KVN), because the beam size of the telescopes is smaller than the size of the nebula. To determine the polarization angle of the Crab nebula as seen by KVN, we use 3C 286, a compact polarized extragalactic radio source whose polarization angle is well-known, as a reference target. We observed both the Crab nebula and 3C 286 with the KVN from 2017 to 2021 and find that the polarization angles at the total intensity peak of the Crab nebula (equatorial coordinates (J2000) R.A. = 05h34m32.3804s and Dec = 22°00'44.0982'') are 154.2° ± 0.3°, 151.0° ± 0.2°, 150.0° ± 1.0°, and 151.3° ± 1.1° at 22, 43, 86, and 94 GHz, respectively. We also find that the polarization angles at the pulsar position (RA = 05h34m31.971s and Dec = 22°00'52.06'') are 154.4° ±0.4°, 150.7° ±0.4°, and 149.0° ± 1.0° for the KVN at 22, 43, and 86 GHz. At 129 GHz, we suggest to use the values 149.0° ± 1.6° at the total intensity peak and 150.2° ± 2.0° at the pulsar position obtained with the Institute for Radio Astronomy in the Millimeter Range (IRAM) 30-meter Telescope. Based on our study, both positions within the Crab nebula can be used as polarization angle calibrators for the KVN single-dish observations.

A Study on Compact Network RTK for Land Vehicles and Real-Time Test Results

  • Song, Junesol;Park, Byungwoon;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제7권1호
    • /
    • pp.43-52
    • /
    • 2018
  • In recent years, the need of high accuracy navigation for vehicles has increased due to the development of autonomous driving vehicles and increase in land transportation convenience. This study is performed for vehicle users to achieve a performance of centimeter-level positioning accuracy by utilizing Compact Network Real-time Kinematic (RTK) that is applicable as a national-level infrastructure. To this end, medium-baseline RTK was implemented in real time to estimate accurate integer ambiguities between reference stations for reliable generation of Network RTK correction using the linear combination of carrier-phase observations and L1/L2 pseudo-range measurements. The residual tropospheric error was estimated in real time to improve the accuracy of double-differenced integer ambiguity resolution between network configuration reference stations that have at least 30 km or longer baseline distance. In addition, C++ based software was developed to enable real-time generation and broadcasting of Compact Network RTK correction information by utilizing an accurately estimated double-differenced integer ambiguity values. As a result, the horizontal and vertical 95% accuracy was 2.5cm and 5.2cm, respectively, without performance degradation due to user's position change within the network.