• 제목/요약/키워드: Reference Extraction

검색결과 402건 처리시간 0.023초

Liquid Membrane Permeation of Nitrogen Heterocyclic Compounds Contained in Model Coal Tar Fraction

  • Kim, Su-Jin;Kang, Ho-Cheol;Kim, Yong-Shik;Jeong, Hwa-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1143-1148
    • /
    • 2010
  • We investigated the separation of nitrogen heterocyclic compound (NHC) contained in a model coal tar fraction comprising four kinds of NHC [indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine (Qu)], three kinds of bicyclic aromatic compound (BAC) [1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN) mixture with ten structural isomers (DMNs; regarded as one component)], biphenyl (Bp) and phenyl ether (Pe) by liquid membrane permeation (LMP). A batch-stirred tank was used as the permeation unit. An aqueous solution of saponin and n-hexane were used as the liquid membrane and the outer oil phase, respectively. Yield and selectivity of individual NHC was much larger than that of BAC, Bp and Pe. Increasing the initial mass fraction of the saponin to the membrane solution ($C_{sap,0}$) and the initial volume fraction of O/W emulsion to total liquid in a stirred tank (${\phi}_{OW,0}$) resulted in deteriorating the yield of individual NHC, but increasing the stirring speed (N) resulted in improving the yield of each NHC. With increasing $C_{sap,0}$, the selectivity of each NHC based on DMNs increased. Increasing ${\phi}_{OW,0}$ and N resulted in decreasing the selectivity of individual NHC based on DMNs. At an experimental condition fixed, the sequence of the yield and selectivity in reference to DMNs for each NHC was Q > Qu = iQ > In. Furthermore, we compared LPM method with methanol extraction method in view of the separation efficiency (yield, selectivity) of NHC.

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

A Study on Correlation among Viewers by Medium based on KBS PIE-TV Index

  • Lee, Jong-Soo;Hamacher, Alaric;Kwon, Soonchul;Lee, Seunghyun
    • International journal of advanced smart convergence
    • /
    • 제6권4호
    • /
    • pp.9-18
    • /
    • 2017
  • In order to respond to the ever-changing media environments in the era of smart and mobile technology, KBS has introduced and partially applied PIE-TV and PIE-nonTV modes that monitor the average number of viewers among the national population group by means of the sample household extraction method which is a traditional way of rating investigation. This study analyzes the correlation between the number of viewers of premiere, re-air broadcasting, and MPP channel programs and the number of OTT-based VOD viewers in reference to the data extracted from PIE-TV survey results. KBS conducted a survey for 3 months between June and August 2017 to measure the PIE-TV Index, based on which the above-mentioned correlation was analyzed with programs classified to entertainment, drama, and cultural programs. For data analysis, SPSS (Ver. 18.0 for Window, SPSS Inc, Chicago, IL, USA) was utilized. It was assumed that when p<0.05 in the confidence interval of 95%, statistically significance would be secured. Among the 30 subjects in the simple correlation analysis, the parameter was determined by the Person correlation coefficient and the non-parameter by the Spearman correlation coefficient. Analysis results are as below: (1) As the number of viewers of premier entertainment, drama, and cultural programs was larger, the number of VOD viewers was larger accordingly. (2) As for entertainment and drama programs, as the number of re-air broadcasting viewers was larger, the number of VOD viewers decreased accordingly. (2) As for entertainment and drama programs, as the number of MPP viewers was larger, the number of VOD viewers decreased accordingly. It is expected that this statistical data can be utilized for strategic planning of MPP channel lineups including terrestrial TV broadcasting, cable TV, etc.

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • 한국축산식품학회지
    • /
    • 제35권4호
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.

초음파 볼륨에서 웨이브렛 변환을 이용한 전립선 객체 추출 (Prostate Object Extraction in Ultrasound Volume Using Wavelet Transform)

  • 오종환;김상현;김남철
    • 전자공학회논문지SC
    • /
    • 제43권3호
    • /
    • pp.67-77
    • /
    • 2006
  • 본 논문에서는 웨이브렛 변환과 SVM 분류기를 이용하여 3차원 초음파 볼륨으로부터 전립선 객체를 추출하는 방법을 제안한다. 제안한 방법에서는 웨이브렛 변환의 수평 수직 방향의 상세 영상들의 평균치들로부터 웨이브렛 변환 모듈러스 영상을 구함으로써 잡음전력 대비 전립선 윤곽에 대한 국부 최대치들의 첨예도가 큰 모듈러스 영상을 얻을 수 있다. 또한 전립선의 밝기 변이 특성 및 전립선 내외부의 질감 차이 등을 특징으로 한 SVM 분류기를 이용함으로써 전립선 윤곽 추출의 정확도를 크게 향상시킬 수 있다. 실험 결과, 제안한 방법을 이용하여 전립선 윤곽을 찾을 경우 전문가에 의하여 추출된 윤곽과 비교하여 절대 평균 거리가 1.89로 나타났다.

맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발 (Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity)

  • 최정현;조욱현;박준호;김남훈;성향숙;조종만
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

가변 탐색블록을 이용한 객체 추적에 관한 연구 (A Study on Object Tracking using Variable Search Block Algorithm)

  • 민병묵;오해석
    • 정보처리학회논문지B
    • /
    • 제13B권4호
    • /
    • pp.463-470
    • /
    • 2006
  • 카메라를 통하여 입력되는 객체의 움직임은 잡음이나 조명의 변화에 따라 정확하게 추출하고 추적하는 것이 어렵다. 실시간으로 입력되는 영상에서 객체를 추출하고 움직임을 추적하기 위해서는 고속탐색 알고리즘이 필요하다. 본 논문에서는 정확한 객체의 움직임을 추출하고 고속 추적을 위하여 배경화면의 변화에 강인한 배경영상 갱신 방법과 가변적인 탐색영역을 이용한 정확하고 빠른 알고리즘을 제안한다. 배경영상 갱신 방법은 임계값이 실험적 기준치 보다 작은 경우에는 배경영상을 갱신하고, 큰 경우에는 객체가 유입된 시점으로 판단하여 픽셀검사를 통해 객체의 윤곽점을 추출한다. 추출된 윤곽점은 객체 최소블록의 생성과 일정한 거리를 유지하는 탐색블록을 생성하여 정확하고 빠른 객체의 움직임을 추적한다. 실험결과, 제안한 방법은 95% 이상의 높은 정확도를 보였다.

바닥 패턴을 이용한 단일영상 내의 피사체 크기 추출 (Extraction of Subject Size in Still Image Using Floor Pattern)

  • 황민구;김동민;하동환
    • 한국콘텐츠학회논문지
    • /
    • 제11권4호
    • /
    • pp.11-17
    • /
    • 2011
  • 본 논문 단일영상 내에 존재하는 피사체의 정보를 객관적인 수치로 구현하는 데 목적이 있다. 이러한 연구를 위해서 2차원의 단일영상이 가진 소실점을 기초로 하였으며, 3D 프로그램을 이용하여 단일영상을 3차원으로 재구성하였다. 또한, 3차원 재구성에 필요한 촬영카메라의 축 설정을 위해서 이미지가 가진 렌즈 화각 및 바닥 패턴을 활용하였다. 이렇게 완성된 3차원 영상은 하나의 기준이 되는 특정 피사체의 크기 값을 안다면 바닥패턴에 있는 모든 피사체의 크기 및 거리 측정이 가능하며 이를 통해 CCTV 또는 기타 범죄 사건의 영상에서 범인 및 단서가 되는 피사체의 기초정보를 획득할 수 있다.

T-50 고등 훈련기 엔진/기체 적합성 검증을 위한 추진계통 비행시험 (Flight Test of Propulsion System for Verifying Engine/Aircraft Compatibility of T-50 Advanced Trainer)

  • 이상효;정인면;정주현;심재광;강성수;박성환;한병학;문형래;차재병;이부일
    • 한국항공우주학회지
    • /
    • 제35권10호
    • /
    • pp.948-956
    • /
    • 2007
  • 항공기를 개발함에 있어 기체를 구성하는 계통의 성능이 항공기 요구도를 만족하는 수준으로 발휘되는지 확인하는 것이 중요하다. 특히, 엔진을 포함한 추진계통은 항공기를 구성하는 구성품 중 중요한 계통으로서, 추진계통과 기체와의 통합성을 검증하는 것이 항공기 개발에 있어 필수적 요소이다. T-50 고등훈련기 체계개발 시 추진계통 검증을 위해 엔진 공중재시동 시험 및 엔진 축마력 시험, backup throttle기능 시험 등의 다양한 비행시험을 수행하였으며, 이와 같은 항목의 비행시험을 통하여 T-50 고등 훈련기의 추진계통이 기체에 적합하게 설계/장착되었음을 확인하였다. 본 논문에서 추진계통 비행시험 항목에 대한 설명 및 시험 절차, 결과를 제시하였으며, 본 논문의 내용이 차후 타 항공기 개발 시 추진계통 관련 비행시험을 준비하는 과정에서 참고가 될 수 있을 것으로 기대한다.

첼렌코프광과 액체섬광계수법을 이용한 89Sr 및 90Sr 분석에 대한 연구 (A Study on the Analysis of 89Sr and 90Sr with Cerenkov Radiation and Liquid Scintillation Counting Method)

  • 이명호;조영현;정근호;최근식;이창우
    • 분석과학
    • /
    • 제15권1호
    • /
    • pp.20-25
    • /
    • 2002
  • 추출크로마토그래피와 액체섬광계수기를 이용하여 기존의 방사성 스트론튬 분석법 단점을 해결하는 신속하고 신뢰성 있는 $^{89}Sr$$^{90}Sr$ 분석법을 개발하였다. 옥살산 공침혹은 양이온 교환수지로 방해원소를 제거한 후 Sr-spec 컬럼을 사용하여 스트론튬만을 순수분리한 후, 액체섬광계수기를 사용하여 $^{89}Sr$에서 방출하는 첼렌코프광을 측정하였고 spectrum unfolding 방법으로 $^{90}Sr$을 정량하였다. 본 연구에서 개발된 방사성 스트론튬 분석법을 환경 표준시료 (IAEA-375, Soil) 및 액체 폐기물시료에 적용하여 분석법의 유효성을 검증하였다.