• 제목/요약/키워드: Reference Artifact

검색결과 46건 처리시간 0.028초

조선 후기 면갑(綿甲) 유물 분석 - 국립중앙박물관 소장 유물을 중심으로 - (An Analysis of the Cotton Fabric armour(綿甲) in the late Joseon Korea - with Emphasis on the Remaining Artifact in the National Museum of Korea -)

  • 박가영;송미경
    • 복식
    • /
    • 제63권4호
    • /
    • pp.158-167
    • /
    • 2013
  • The cotton fabric armour for lower class soldiers can be found from the historical records of the mid-Joseon Korea. And the records show that the form and the structure of the armour was modified in the late 19th century in order to provide better protection from gunshots for the soldiers in the midst of the invasions from the West. This is a survey and research of the only artifact of the cotton fabric armour remaining in Korea - for its form, dimensions, and design. Using the historical records as reference, we can confirm the structure and characteristics of the cotton fabric armour of the Joseon period. This cotton fabric armour, preserved in National Museum of Korea, is a vest-type armour made of 30 layers of cotton. On the right shoulder, there is a button for tying knots and strings were tied under both armpits. On the surface of the cotton fabric armour there were some characters and patterns stamped in black. Presently, this artifact in Korea is the only specimen relic of its sort, but there are some other related relics in foreign countries including helmets and belts. Continuous researches would help extend the scope of armour study beyond the traditional researches that only focuses on the armours of the officials, thus helping us to understand the military costumes in traditional Korea.

고려(高麗) 철제석가여래좌상(鐵製釋迦如來坐像)의 보존 (Conservation of Seated Iron Śākyamuni Buddha Statue from Goryeo Dynasty)

  • 허일권;유자영
    • 박물관보존과학
    • /
    • 제11권
    • /
    • pp.9-16
    • /
    • 2010
  • 국립춘천박물관은 고려 철제석가여래좌상의 부식방지와 상설전시 활용을 위하여 보존처리를 실시하였다. 처리 전 유물의 상태는 부식으로 인한 표면 박락현상이 관찰되었고 가부좌의 오른편 둔부에서 다리부분까지 결손되어 정상적인 전시가 불가능 하였다. 따라서 표면의 이물질을 제거하고 강화·보호 위한 강화처리 작업이 진행되었다. 강화처리 진행에 앞서 국내·외 연구 자료를 바탕으로 micro crystalline wax계를 선정하여 기초 실험을 실시하였다. 그 결과 (주)동남유화의 wax(in xylene) 5wt%가 백화현상과 표면 색상변화가 적으며 작업에 편리성이 높아 강화제로 선택하여 부식을 억제하였다. 결손부분의 복원은 내부 지지대 제작과 함께 epoxy계 수지를 이용하여 탈착이 가능한 복원을 실시하여 전시 효용성을 높였다.

토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험 (Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study)

  • 김대건;정재홍;김성철
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.709-718
    • /
    • 2022
  • 본 연구의 목적은 토모테라피 방사선치료에서 고밀도 알루미늄, 티타늄, 강철 금속 삽입물에 대한 단층촬영(CT)을 평가하고 자 하였다. 다양한 밀도의 원통형 막대를 포함한 금속 삽입물과 함께 원통형 토모팬텀을 이용하여 영상을 얻었다. 총 세 가지의 CT 영상에 대해 평균 CT 값(number)와 표준 편차를 구하고, 치료계획 선량평가도 수행하였다. 고밀도 금속 삽입물이 CT값과 변화가 가장 컸다. 타겟에 대한 선량평가(적합성 지수, CI)에서 반복적 금속 인공물 감소 알고리즘(iMAR)이 적용된 영상이 그렇지 않은 영상에 비해 약 20% 좋았으나 유의한 차이는 없었다. iMAR은 표적 및 장기의 묘사에 도움을 주고 토모테라피를 이용한 3차원 입체조형 방사선치료기술(3D-CRT)에서 불확실성을 줄이는 데 도움이 될 것으로 사료된다.

전염병 구획 모형에 대한 시스템다이내믹스 접근법: 국내 MERS 전염 SEIR 모형의 해석 및 변환 (System Dynamics Approach to Epidemic Compartment Model: Translating SEIR Model for MERS Transmission in South Korea)

  • 정재운
    • 디지털융복합연구
    • /
    • 제16권7호
    • /
    • pp.259-265
    • /
    • 2018
  • 수학모형의 한 유형인 구획모형은 전염병의 확산처럼 순차적인 이벤트나 프로세스로 구성된 동적 시스템의 변화를 분석하는 데 폭넓게 활용되어 왔다. 구획모형은 상자와 화살표로 표현되는 구획과 구획 간 관계로 구성된다. 이러한 원리는 stock과 flow로 구성되는 시스템다이내믹스(SD)의 모델링 원리와 비슷하다. 두 모형 모두 미분방정식을 이용하여 구조화된다. 이와 같은 두 모형 간 변환 가능성을 이용하여 국내 MERS 전염의 특징을 분석한 최근 연구의 SEIR 참조모형을 SD 관점에서 해석 변환한다. 변환된 SEIR 모형(Model 2)은 참조모형(Model 1)의 재현 결과와 비교하여 동일한 시뮬레이션 결과를 나타내었다. 본 연구는 전염병 구획모형의 구축에 도식과 미분방정식을 이용한 SD 방법론의 활용에 대한 인사이트를 제공하며, 변환된 SD 모형은 다른 전염병을 위한 참조모형으로 활용 가능하다.

Characterizing a full spectrum of physico-chemical properties of (20S)-and (20R)-ginsenoside Rg3 to be proposed as standard reference materials

  • Kim, Il-Woung;Sun, Won Suk;Yun, Bong-Sik;Kim, Na-Ri;Min, Dongsun;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • 제37권1호
    • /
    • pp.124-134
    • /
    • 2013
  • The authentication of the physico-chemical properties of ginsenosides reference materials as well as qualitative and quantitative batch analytical data based on validated analytical procedures is a prerequisite for certifying good manufacturing practice (GMP). Ginsenoside Rb1 and Rg1, representing protopanaxadiol and protopanaxatriol ginsenosides, respectively, are accepted as marker substances in quality control standards worldwide. However, the current analytical methods for these two compounds recommended by Korean, Chinese, European, and Japanese pharmacopoeia do not apply to red ginseng preparations, particularly the extract, because of the relatively low content of the two agents in red ginseng compared to white ginseng. In manufacturing fresh ginseng into red ginseng products, ginseng roots are exposed to a high temperature for many hours, and the naturally occurring ginsenoside Rb1 and Rg1 are converted to artifact ginsenosides such as Rg3, Rg5, Rh1, and Rh2 during the heating process. The analysis of ginsenosides in commercially available ginseng products in Korea led us to propose the inclusion of the (20S)- and (20R)-ginsenoside Rg3, including ginsenoside Rb1 and Rg1, as additional reference materials for ginseng preparations. (20S)- and (20R)-ginsenoside Rg3 were isolated by Diaion HP-20 adsorption chromatography, silica gel flash chromatography, recrystallization, and preparative HPLC. HPLC fractions corresponding to those two ginsenosides were recrystallized in appropriate solvents for the analysis of physico-chemical properties. Documentation of those isolated ginsenosides was achieved according to the method proposed by Gaedcke and Steinhoff. The ginsenosides were subjected to analyses of their general characteristics, identification, purity, content quantification, and mass balance tests. The isolated ginsenosides showed 100% purity when determined by the three HPLC systems. Also, the water content was found to be 0.534% for (20S)-Rg3 and 0.920% for (20R)-Rg3, meaning that the net mass balances for (20S)-Rg3 and (20R)-Rg3 were 99.466% and 99.080%, respectively. From these results, we could assess and propose a full spectrum of physico-chemical properties of (20S)- and (20R)-ginsenoside Rg3 as standard reference materials for GMP-based quality control.

두부 CT에서 차폐기법과 새로운 관전류변조기법에 따른 눈의 선량과 화질평가 (The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT)

  • 권순무;김정수
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.279-285
    • /
    • 2015
  • 두부 CT 검사에서 눈의 수정체는 높은 방사선 감수성으로 보호되어야 할 장기 중에 하나이다. 두부 CT 검사에서 눈의 피폭선량감소 목적으로 사용되는 비스무스 차폐체는 현저한 선량 감소 효과가 있지만 화질저하의 문제점이 있다. 본 연구는 인체팬텀을 이용한 두부 CT 검사에서 피폭 선량을 줄이기 위해 사용되는 관전류변조기법인 new organ based-tube current modulation, longitudinal-TCM, angular-TCM과 차폐기법인 비스무스, 납 안경을 사용하여 눈의 선량과 화질의 변화 정도를 평가하였다. 연구결과, new OB-TCM에서 눈의 선량은 25.88% 감소되었으며 비스무스를 사용한 검사와 비교하여 CT number, 노이즈, SNR의 변화가 작은 것을 확인하였다. 따라서 new OB-TCM을 임상의 두부 CT 검사에 적용할 경우, 눈의 피폭선량을 감소시키면서 영상의 화질 저하를 방지할 수 있을 것으로 기대된다.

생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리 (Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device)

  • 이한욱;이주원;정원근;김성후;이건기
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

진열장 조명의 이론적 기준과 시설에 대한 고찰 (An Approach to the Theoretical Design Standard and Effective Practice of Museum Showcase Lighting)

  • 김홍범
    • 보존과학연구
    • /
    • 통권17호
    • /
    • pp.123-160
    • /
    • 1996
  • There have been many studies and experiments regarding exhibition lighting. Many experiments on photochemical damaging effect and visibility resulted in a practice limited to assigning light levels and adjusting annual exposure time. The three damaging factors to the artifacts are intrinsicsusceptibility to absorb radiant energy, spectral distribution of light source and intensity of illumination and time of exposure. Dividing all the artfacts into three categories to suggest a recommended illuminance level causes some problems. Blue wool, for example, used as the reference material for susceptibility, is not a standard material representing museum artifacts. In the most light sensitive category, ISO class I or anything below have been excluded. The exposure time of one soure can be three times more than another sourece. The spectral distribution of the light source and the relative spectral responsibility of the artifact are not considered in the practice. So in case of very light sensitive material, the recommended illuminance is only the referring value and it is indispensable to check the characteristic of susceptibility of each artifacts. Daylighting is prevailing method to solve the psychological need of the visitors. However, it sould transparent, and should not diffused, and the green-house effect must be considered. llluminance uniformity should based on the maximum illuminance to handle the limitation of exposure for the conservation of a large sensitive object such as a painting. Damage index is not absolute reference for selecting the lighting source because it is experimented from the paper of low grade then calculated. Visibility should be increased by reducing the visual noiseand by planning of appropriate luminance contrast. This paper reviews the problems with the previous studies and experiment sand the current exhibition lighting design practice. The plan for museum showcase lighting is to check the susceptibility and to raise the visibility simultaneously.

  • PDF

적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법 (Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter)

  • 박호동;장봉렬;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

손목형 생체신호수집 장치에 대한 연구 (A Study on Wrist Band Type Vital Sign Acquisition Device)

  • 김희훈;김경호
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.