• Title/Summary/Keyword: Reduction Potential

Search Result 2,671, Processing Time 0.03 seconds

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.

Relationship Between Tyrosinase Inhibitory Action and Oxidation-Reduction Potential of Cosmetic Whitening Ingredients and Phenol Derivatives

  • Sakuma, Katsuya;Ogawa, Masayuki;Sugibayashi, Kenji;Yamada, Koh-ichi;Yamamoto, Katsumi
    • Archives of Pharmacal Research
    • /
    • v.22 no.4
    • /
    • pp.335-339
    • /
    • 1999
  • The oxidation-reduction potentials of cosmetic raw materials, showing tyrosinase inhibitory action, and phenolic compounds structurally similar to L-tyrosine were determined by cylcic voltammetry. The voltammograms obtained could be classified ito 4 patterns (patterns 1-4). Patterns 1, characterized by oxidation and reduction peaks as a pair, was observed with catechol, hydroquinone or phenol, and pattern 2 exhibiting another oxidation peak in addition to oxidation and reduction peaks as a pair was found with arbutin, kojic acid, resorcinol, methyl p-hydroxybenzoate and L-tyrosine as the substrate of tyrosinase. Pattern 3 with an independent oxidation peak only was expressed by L-ascorbic acid, and pattern 4 with a reduction peak only at high potentials, by hinokitiol. The tyrosinase inhibitory activity of these compounds was also evaluated using the 50% inhibitory concentration ($IC_{50}$) and the inhibition constant (Ki) as parameters. Hinokitiol, classified as patterns 4, showed the highest inhibitory activity (lowest $IC_{50}$ and Ki). Hydroquinone showing the second highest activity belonged to pattern 1, which also included compounds exhibiting pattern 2 was relatively low with Ki values being in the order of 10-4 M. Although there was no consistent relationship between oxidation-reduction potentials and tyrosinase inhibitory action, the voltammetry data can be used as an additional index to establish the relationship between the structure and the tyrosine inhibitory activity.

  • PDF

Method-Free Permutation Predictor Hypothesis Tests in Sufficient Dimension Reduction

  • Lee, Kyungjin;Oh, Suji;Yoo, Jae Keun
    • Communications for Statistical Applications and Methods
    • /
    • v.20 no.4
    • /
    • pp.291-300
    • /
    • 2013
  • In this paper, we propose method-free permutation predictor hypothesis tests in the context of sufficient dimension reduction. Different from an existing method-free bootstrap approach, predictor hypotheses are evaluated based on p-values; therefore, usual statistical practitioners should have a potential preference. Numerical studies validate the developed theories, and real data application is provided.

Research on Buried Depth Dependent Characteristics of Potential Rise for Structure (구조물 전위상승의 매설깊이 의존특성에 관한 연구)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.104-108
    • /
    • 2007
  • This paper deals with an approach to the reduction of potential rise according to the buried depth of structure. In order to analyze the surface potential rise of structure, an electrolytic tank which simulates the semi-infinite earth has been used. The potential rise has been measured and analyzed for types of structure using an electrolytic tank experimental apparatus in real time. The structure models were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. When a test current flowed through structure models, potential gradient was the highest value in case of the outline frame type(structure model A). The distributions of surface potential rise are dependent on the resistivity and absorption percentage in concrete attached to structure model.

Assessment of Project Cost Reduction Potential Adopting Cases-Synthetic Approach - Focused on the Apartment Building Construction Project - (시공방법 개선사례 조합에 의한 원가절감 가능성 평가)

  • Choi, Jong-Soo;Choi, Young-Jun;Chae, Seong-Tae;Yoo, Sung-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.135-144
    • /
    • 2009
  • The primary focus of this study has been directed towards assessing the potential impact of construction method improvement on a reduction in project cost. A total of 90 actual application cases were collected from a public organization and private construction firms, and 32 cases were used in analysis by adopting a synthetic approach. The level of cost reduction was measured in terms of material and labor cost by comparing the existing method and the improved method. An analysis of the results indicates that project cost can be reduced by up to 5.26 percent compared to a normal project by adopting a synthetic approach. Additional benefits include the assurance of uniform quality, savings in terms of labor and/or materials, and improved productivity. The potential of the applicability of this approach to other types of buildings and the implications of research findings were discussed in detail.

Effects of Bubble Discharge on pH and Oxidation/Reduction Potential Change by Non-Uniform Electric Field (불평등전계에 의한 기포방전이 수소이온농도와 산화환원전위변화에 미치는 영양)

  • 김진규;김광태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.77-82
    • /
    • 2003
  • In this paper, as the new type of multi-lines electrode which can formulate strong non-uniform electric field was installed in strong electrolytic water generator, shapes of pre-discharge in bubble and effects of bubble discharge on pH and oxidation/reduction potential change were intended to investigate. Consequently, as multi-lines electrode was installed in side of anode, pre-discharges generated from anode electrode could be observed. This pre-discharge was generated from differences of permittivities between bubble and water in strong non-uniform electric field. And ion concentration in electrolytic water generator was increased by dissolving of ions generated from bubble discharge. So, as generated high concentration ions were separated and assembled to each electrode and reaction of oxidation/reduction was increased, it was shown that strong electrolytic water could be generated.

A Study on Sectoral Burden Sharing for Greenhouse Gas Emissions Mitigation (온실가스 감축을 위한 부문별 책임할당방안 연구)

  • Lee, Sang-Youp;Choi, Kyong-Sik
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.171-198
    • /
    • 2009
  • The issue of burden sharing between sectors has become a pertinent national issue with respect tothe establishment of national greenhouse gas (GHG) reduction targets, and the means to achieve these targets. This study explores methods for equitable sectoral allocation to reduce GHGs based on an allocation index taking into account relevant attributes in line with national GHG emissions trends and structures. This paper considered potential for GHG reduction, rate of increase of emissions, and ability to pay as suitable criteria for analysis of each sector. As a result of the analysis, it was found that equitable allocation methods have significantly different burden sharing compared to allocation that considers only potential for GHG reduction. Accordingly, further empirical study on various simulations based on national economic impact will be essential for better policy solutions. This study will contribute to applying national allocation plans in a logical, consistent and transparent manner.

  • PDF

Electrochemical Reduction of Iodine in Non-aqueous Solvents (물아닌 용매속에서의 요오드의 전기화학적 환원)

  • Park Doo Won;Choi Won Hyung
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.104-115
    • /
    • 1975
  • The electrochemical reduction of iodine in non-aqueous media have been studied by polarography, chronopotentiometry, cyclic voltammetry and controlled potential coulometry at dropping mercury electrode and platinum, gold and amalgamated platium electrodes. In amphiprotic solvents such as methanol, ethanol, isopropanol and pyridine, iodine were reduced to iodide ions via one step reduction involving 1 electron and in aprotic solvents such as acetonitrile, dimethylformamide and dimethylsulfoxide via two step reduction involving all 3 electrons. The reductions of iodine give well defined polarograms at dropping mercury electrode and irreversible chronopotentiograms at platinum electrode, but less defined irreversible chronopotentiograms at gold and amalgamated platinum electrodes, those are all diffusion controlled. The diffusion coefficients of iodine in various solvents were estimated from the chronopotentiometric data and Sand equation.

  • PDF

Potential Reduction and Energy Dispersion Due to Ionization Around the Submerged Ground Rod (수중에 잠긴 접지전극 주변에서의 이온화에 의한 전위저감 및 에너지방출)

  • Choi, Jong-Hyuk;Ahn, Sang-Duk;Yang, Soon-Man;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.92-99
    • /
    • 2009
  • Deeply-driven ground rod in the rainy season may contact with rainwater and ground water. When surge voltages are applied to the submerged ground rods, the ionization around the ground rods are occurred. Ionization in soil and/or water is affected in dynamic performance of ground rod systems. This work aims at studying the transient performance of ground rod system under impulse voltage using scale model in an electrolytic tank. The potential reduction and energy dispersion caused by ionization were treasured and quantitatively analyzed using the Matlab Program. As a result, the peak voltage at the terminal of ground rod was varied with water resistivity and charging voltage of Marx generator. The potential at the terminal of the ground rod was approximately reduced to a half of the applied voltage just below breakdown voltage. Also the energy more than half of the applied energy was dispersed through the ground rod due to ionization just below breakdown voltage.

Reduction Potential for Thermal Load by Extensive Green Roofs (경량형 옥상녹화에 따른 열부하 저감 잠재성 연구)

  • Kim, Yeon Mee;Nam, Mi A;Jang, Dae Hee;Kim, Hyeon Soo;Kim, Hyun Ok
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.67-77
    • /
    • 2013
  • Based on the increasing demand for a solution to reduce thermal load, extensive green roofs have great opportunity for application to existing roofs due to their light-weight and easy maintenance. The present study delivers data regarding thermal behavior and heat reduction potential in relation to vegetation coverage between green roof types. 1) In the hottest hour in a day, green roofs showed considerable potential to mitigate heat load in roof environments, which can be up to $10^{\circ}C$ difference. 2) Compared to conventional cement roofs, the extensive green roofs only have a slight potential to cool the air over green roofs. By statistical analysis of linear regression, green coverage has little to do with the reduction of air temperature; the cooling effect was proven only in nighttime. 3) Green roofs act as an insulating roof membrane, the inner substrate of green roofs remained cooler than cement roof surfaces in the daytime, but in the nighttime the green roofs generally were warmer than the cement roof surfaces. 4) The variable of vegetation coverage resulted in no significant difference in thermal behavior in the air, but had the greatest effect in keeping the substrate cool in the daytime. The high vegetation coverage also hindered the rapid cooling of the substrate in the nighttime, and therefore was warmer than other measured temperatures. In order to draw a clear conclusion to combat urban heat island effect with extensive green roofs, the experiment needs to be applied on a larger scale.