• Title/Summary/Keyword: Reducing Building Energy

검색결과 249건 처리시간 0.022초

BIM 기반의 저에너지 주거공간 설계 기법 연구 (A BIM-based Design Method for Energy-Efficient Housing)

  • 윤승현;박남희;최진원
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.187-192
    • /
    • 2009
  • Nowadays, global warming and high oil prices were a threat to the survival of the whole human race. One of a solution to respond to these problems is to reduce energy consumption of building. By adopting energy-saving design, the dissemination of low energy building is required. Therefore, to improve energy efficiency while reducing the usage of the design method is necessary to study actively. BIM-based systems applied to buildings, scheduled to be built by reducing the amount of energy reduction technologies can be analyzed. Depending on various design and equipment to set energy savings goals, you can select an alternative. If it is possible to predict the energy efficiency from the initial stage of design and support designing low energy building, we would be able to expect improvement in the economics of housing due to the reduction of energy consumption.

  • PDF

건물에너지 효율향상을 위한 최적화 툴의 개발 (Development of Optimization Program for the Building Energy Efficiency Improvement)

  • 한수곤;임병찬;허정호;권한솔
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.223-228
    • /
    • 2005
  • This study develops an optimization program to use optimum design of building HVAC system reducing building energy use and cost. Doe20pt developed is an interface program between DOE2 and GenOpt to perform the optimization procedure more easily. The optimum results can be used to estimate the economical efficiency concerning the building management.

  • PDF

공동주택에서의 창호성능에 따른 건물에너지 효율등급 평가 연구 (A Study on the Evaluation of Building Energy Rating considering the Insulation performance of the Window in Apartment houses)

  • 김치훈;안병립;홍성희;장철용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.291-295
    • /
    • 2009
  • As a reasonable energy policy has become required because of consuming substantial amounts of oil than others, the studies on energy consumption are in work for energy savings of buildings that spend up to 24% of total energy consumption. However, there aren't basic data on energy consumption and installationregulations for effective equipments in energy guzzled buildings. The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. Thus, we should prepare the alternatives to improve insulation performance of envelopes and the efficiency of insulation performance of the window for reducing energy consumption.

  • PDF

에너지파일과 에너지슬래브 적용 지열원 열펌프 시스템의 일일 냉방 운전 특성 비교 (Daily Cooling Performance Comparison of a Geothermal Heat Pump System between Energy-Pile and Energy-Slab)

  • 최종민;박용정;강신형
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.29-35
    • /
    • 2012
  • Geothermal heat pump system has been spotlighted as an efficient building energy system, because it has great potentials for reducing energy in building air conditioning and reducing $CO_2$ emissions. However, higher initial cost is a barrier to the promotion of its use. Energy-pile and energy-slab are known as low cost ground heat exchangers comparing with conventional ground heat exchangers, because they utilize building structures as ground heat exchangers. This paper presents the daily cooling performance of a geothermal heat pump system with energy-pile and energy-slab. The energy-piles and the energy-slabs are connected to heat pump units in parallel. The cooling capacity of the system was nearly constant due to the stability of the ground heat exchangers. The stability of the energy-pile was a little higher than that of the energy-stab as a heat sink.

Electrochromic 창호 적용시 지역별 건물 냉난방 에너지 소비량 절감성능 (Performance Evaluation of Electrochromic Window System by Different Orientations and Locations in Korea)

  • 신재윤;채영태
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.75-84
    • /
    • 2018
  • The most crucial point of reducing building energy is application of high performance envelope. The amount of heat exchange through window is highest in comparison of other envelopes so that heat exchange through window influence directly with building energy consumption. The window energy performance can be define with thermal, leakage and optical performance. In previous study we can confirmed that not only thermal performance but also optical performance are considered, 11% to 15% of building energy consumption can be reduced. Smart window system has potential of energy saving so that many industry field use smart window system including architectural area and these aspect causes smart window market continuous growth year by year. In this study, building energy consumption has been analyzed which consist of smart window that dynamically control optical states. The consideration of standard commercial building model for research, the reference medium size commercial building model of DOE (Department Of Energy, USA) has been used. The building energy simulation result of 4 axis in 8 regions in Korea shows 8% to 22% reduction of building energy consumption by application of smart window system.

고층 빌딩에 적용되는 빌딩통합형 태양광패널 효율성 개선방안 (Efficiency Improvement for Building Integrated Photovoltaic Applied to High-rise Building)

  • 이도현;안인석
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2022
  • With the advent of cutting-edge technology, renewable energy is significantly considered as alternative resources to supply electric power. However, many barriers such as energy intermittency, high initial installation cost, and low-efficiency generation challenged building new infrastructure with clean energy. Efforts reducing greenhouse gas emissions and reliance on fossil fuels resulted in the decentralization of power generation like distributed energy resource (DER). This paper is to introduce and evaluate the feasibility of building-integrated photovoltaics (BIPV) in a high-rise building in Ulsan. To optimize BIPV, a variety of methods to minimize efficiency decrease and maximize electric power generation after installing BIPV on the building's facade are suggested. The variables causing power losses are analyzed. By utilizing System Advisor Model (SAM), actual power generated from solar panels is measured by Thin-film PV, Mono-crystalline PV, and Poly-crystalline PV.

기존 건축물의 온실가스 감축을 위한 리모델링 기술 개발 (Remodeling Techniques for Reducing Greenhouse Gases Emissions in Existing Buildings)

  • 권철환;박종섭
    • 복합신소재구조학회 논문집
    • /
    • 제7권1호
    • /
    • pp.45-52
    • /
    • 2016
  • There are only 10 projects of the domestic greenhouse gas(GHG) emissions trading scheme in building sector (i.e., 1.5% of 652 registered projects) because the certified methodologies to reduce GHG emissions can not be applied to building sector. This study presents remodeling techniques to reduce GHG emissions in existing buildings. First of all, preconditions and related regulations were reviewed. And then, a pool of factors for GHG reduction are selected and evaluated with respect to factors for reducing energy consumption. This study also investigates the criteria and the decision making process for remodeling techniques to reduce GHG emissions. Finally, the remodeling techniques using the decision making process were grouped based on redundancy of each effect. If reducing methodologies for GHG offset program can be developed using the analyzed remodeling techniques in this study, registered projects in building sector would be increase.

Application of Energy Dissipation Technology in High-Rise Buildings

  • Hu, Da-Zhu;Zhang, Xiao-Xuan;Li, Guo-Qiang;Sun, Fei-Fei;Jin, Hua-Jian
    • 국제초고층학회논문집
    • /
    • 제10권2호
    • /
    • pp.137-147
    • /
    • 2021
  • The principle of energy dissipation technology is to dissipate or absorb the seismic energy input through the deformation or velocity change of dampers installed in the main structure of high-rise buildings, so as to reduce the seismic response of the buildings. With the development of energy dissipation technology, recognized as an effective and new measurement for reducing seismic effects, its application in high-rise buildings has become more and more popular. The appropriate energy dissipation devices suitable for high-rise buildings are introduced in this paper. The effectiveness of energy-dissipation technology for reducing the seismic response of high-rise buildings with various structural forms is demonstrated with a number of actual examples of high-rise buildings equipped with various energy dissipation devices.

VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구 (A Study of applying VAV and VWV System to reduce Energy Consumption of Office building)

  • 송지용;홍원화;김지연;박효순
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.