• 제목/요약/키워드: Reduced mechanism

검색결과 2,190건 처리시간 0.034초

RCCI/SCCI 조건하에서 희박 PRF/공기 혼합물의 점화에 관한 직접수치모사를 이용한 비교 연구 (DNSs of the Ignition of a Lean PRF/Air Mixture under RCCI/SCCI Conditions: A Comparative Study)

  • ;유광현;유춘상
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.179-182
    • /
    • 2014
  • A comparative DNS study of the ignition characteristics of dual-fueled reactivity controlled compression ignition (RCCI) and stratification charge compression ignition (SCCI) is investigated using a 116-species reduced primary reference fuel (PRF) mechanism. In the RCCI combustion, two PRF fuels (n-heptane and iso-octane) with opposite autoignition characteristics are separatedly supplied and in-cylinder blended such that spatial variations in fuel reactivity, fuel concentration and temperature are achieved. In the SCCI combustion, however, just a single fuel (PRF50) is used such that only fuel concentration and temperature inhomoginieties are obtained. Because three factors, rather than only two as in SCCI combustion, govern the overall RCCI combustion, combustion timing and combustion duration or heat release rate of RCCI combustion are flexibly and effectively controlled. It is found that the overall RCCI combustion occurs much earlier and its combustion duration is longer compared to SCC combustionI. Moreover, the negative temperature coefficient (NTC) has a positive effect on enhancing RCCI combustion by inducing a shorter combustion timing and a longer combustion duration as a result of the occurrence of a predominant low-speed deflagration-combustion mode.

  • PDF

Molybdenum이 납 중독 랫드의 말초신경내 myo-inositol uptake 시스템에 미치는 영향 (Effects of molybdenum on myo-inositol uptake system in peripheral nerve isolated from lead-intoxicated rat.)

  • 송진호;정명규
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.60-66
    • /
    • 2003
  • This study was carried out to elucidate the preventive mechanism of molybdenum on lead-induced neuropathy, An animal model of lead neuropathy was induced by feeding diet containing lead to Sprague-Dawley rat for three weeks. Four weeks aged Sprague-Dawley rats were divided into four groups : normal control group, 10ppm-lead treated group, 1mg/kg-molybdenum treated group, 10ppm-lead and 1mg/kg-molybdenum treated group. The parameters on neuropathy were examined by measuring concentration of myo-inositol and myo-inosito uptake in sciatic nerve. In the lead-treated rats, myo-inositol concentration and myo-inositol uptake rate were reduced by from 54% to 33% respectively. This deficit results from that myo-inositol uptake system which is carrier mediated and sodium-potassium dependent was inhibited by the lead treatment. However, the molybdenum administration significantly eliminated the impairment and maintained myo-inositol concentration to about 82% of normal level. These results suggest that lead-induced neurotoxicity was significantly reduced by administration of molybdenum and the mechanism might be partly normalization of myo-inositol uptake system in sciatic nerve.

와동과 상호작용하는 대향류 비예혼합화염의 비정상 응답특성 (Unsteady Response of Counterflow Nonpremixed Flames Interacting with a Votex)

  • 오창보;박정;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.52-60
    • /
    • 2002
  • A two-dimensional direct numerical simulation is performed to investigate the flame structure of $CH_4/N_2-Air$ counterflow nonpremixed flame interacting with a single vortex. The detailed transport properties and a modified 16-step augmented reduced mechanism based on Miller and Bowman's detailed reaction mechanism are adopted in this calculation. To quantify the strain on flame induced by a vortex, a scalar dissipation rate (SDR) is introduced. Results show that the fuel and air-side vortex cause an unsteady extinction. In this case, the flame interacting with a vortex is extinguished at much larger SDR than steady flame. It is also found that air-side vortex extinguishes a flame more rapidly than fuel-side vortex. The unsteady effect induced by flame-vortex interaction does not lead to a transient OH overshoot of the maximum steady concentration observed in experiment, while $HO_2$ radical increases more than the maximum steady concentration with increasing SDR. In addition, it is seen that NO and $NO_2$ are not sensitive to the unsteady variation of SDR.

  • PDF

High operating temperature stable OLEDs with reduced reflectivity cathodes

  • Popovic, Zoran D.;Aziz, Hany;Vamvounis, George;Hu, Nan-Xing;Paine, Tony
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.21-24
    • /
    • 2003
  • The understanding of the mechanism of device degradation has been accomplished recently, for devices using $AlQ_3$ electron transport and emitter molecule. In this presentation the experimental evidence for the degradation mechanism of $AlQ_3$ based devices will be reviewed, showing that the hypothesis of an unstable $AlQ_3^+$ cation explains a large amount of experimental data. This hypothesis, however, explains not only the room temperature device degradation in time but also sheds light on temperature stability of OLEDs. Dependence of half-life of a series of devices with an emitter layer composed of a mixture of $AlQ_3$ and different hole transport molecules (mixed emitter layer) will be discussed when they are operated at elevated temperatures. These results can also be explained in the framework of an unstable $AlQ_3^+$ species. An OLED structure containing a doped mixed emitter layer will be described, which shows extraordinary stability, half-life of 1200 hours at operating temperature of 70 C and initial luminance of 1650 $cd/m^2$. We will also discuss a novel Black $Cathode^{TM}$ OLED with reduced optical reflectivity, which is also stable at elevated temperatures. The new cathode utilizes a conductive light-absorbing layer made of a mixture of metals and organic materials.

  • PDF

기저핵 운동회로와 파킨슨 증상의 신경생리 (Basal Ganglia Motor Circuit and Physiology of Parkinsonism)

  • 손영호
    • Annals of Clinical Neurophysiology
    • /
    • 제8권2호
    • /
    • pp.107-124
    • /
    • 2006
  • The basal ganglia are a group of nuclei located in the deep portion of the brain. Along with the cerebellum, the basal ganglia have a major role in controlling human voluntary movements, and their dysfunction is apparently responsible for various involuntary movements. Although the exact mechanism of how the basal ganglia control movements has yet to be clarified, the model of focused selection (through the direct pathway) and tonic inhibition (via the indirect pathway) is proposed to be a principal functional model of the basal ganglia. Parkinson's disease (PD) is classically characterized by bradykinesia, rigidity and tremor-at-rest. All features seem to be associated with dopamine depletion resulting from the degeneration of the nigrostriatal pathway, which produces reduced activity of the direct pathway and a concurrent enhancement of excitatory output from STN. This change may result in increased tonic background inhibition and reduced focused selection via the direct pathway, causing difficulties in performing voluntary movements selectively. However, it has not been possible to define a single underlying pathophysiologic mechanism that explains all parkinsonian symptoms. Here the data that give separate understanding to each of the three classic features are discussed.

  • PDF

UMTS-WLAN간 핸드오버를 위한 USIM 기반의 인증 테스트베드에 관한 연구 (A Study on USIM-based Authentication Testbed for UMTS-WLAN Handover)

  • 노광현;권혜연
    • 융합신호처리학회논문지
    • /
    • 제10권1호
    • /
    • pp.66-71
    • /
    • 2009
  • 3GPP에서는 넓은 서비스 영역과 높은 이동성의 장점을 가지는 3G 이동통신과 높은 데이터 전송률의 장점을 가지는 WLAN간 인터워킹 시스템에 대한 표준화 및 기술 개발이 진행되고 있다. 3GPP와 WLAN 이종망간의 서비스 연속성을 지원하기 위해서는 seamless handover를 지원해야하며 이를 위해서는 핸드오버시 발생하는 지연을 최소화해야 한다. 본 논문에서는 행드오버 과정에서 발생하는 지연 시간의 많은 부분을 차지하는 인증 메커니즘을 실제 USIM 기반의 인증 테스트베드에 구현하여 분석하였다. EAP-AKA 완전 인증 방법과 빠른 재인증 방법에 대해 단말과 AAA 서버에서 발생하는 지연 시간을 구체적으로 분석하였고, 실험 결과 빠른 재인증 방법이 인증에 소요되는 시간을 48.6% 단축시킬 수 있는 것으로 측정되었다.

  • PDF

케로신을 연료로 하는 10톤급 액체로켓엔진의 냉각 기구에 관한 연구 (A Study on the Cooling Mechanism in Liquid Rocket Engine of 10tf-Thrust Level using Kerosene as a Fuel)

  • 한풍규;남궁혁준;조원국
    • 한국항공우주학회지
    • /
    • 제31권10호
    • /
    • pp.66-72
    • /
    • 2003
  • 우주발사체의 2단용 엔진으로 10톤급 케로신 액체로켓엔진에 대한 냉각 기구로서, 재생냉각과 막냉각을 고려한 냉각특성에 대한 해석전 연구를 수행하였다. 연소기 내에서 연소 가스의 유동이 축방향으로 층류화되어 있다는 개념하에, 엔진 단면을 서로 독립적인 중심부와 외곽부로 나누며, 외곽부에는 여분의 연료를 분무시킴으로써 연소가스 온도를 낮추어 냉각채널로 전달되는 열유속량과 벽면 온도를 감소시킬 수 있었으며, 엔진의 열적 안정성을 향상시킬 수 있었다.

알루미늄 합금의 소실모형주조 중 기포 형성 기구에 관한 연구 (The Study on the Formation Mechanism of Gas Pore During Lost Foam Casting of Al alloys)

  • 신승렬;한상원;이경환;이진형
    • 한국주조공학회지
    • /
    • 제23권5호
    • /
    • pp.268-275
    • /
    • 2003
  • The mechanism of the hydrogen gas pore formation was investigated in Lost Foam Casting of Al-alloy by reduced pressure test and real casting. The hydrogen gas pick-up was affected by the formed gas during the decomposition of polystyrene in addition to the liquid product. It depended on pouring temperature and a proper temperature of metal front gave the minimum hydrogen pick-up. At a low pouring temperature, the hydrogen went into the melt mainly from entrapped liquid product of polystyrene but pores were formed from the gas as well as the liquid product at a high pouring temperature. The mold flask evacuation down to 710torr decreased the gas porosity down by around 0.4% vol%. The entrapped decomposition product of polystyrene in the melt was observed through the visualization of filling behavior of Al alloy-melt with the high speed camera.

Improvement of the behaviour of composite slabs: A new type of end anchorage

  • Fonseca, Alexandre;Marques, Bruno;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1381-1402
    • /
    • 2015
  • The application of composite steel-concrete slabs with profiled steel sheeting has increased, due to the various advantages in relation to reinforced concrete slabs such as, the reduced thickness, the reduced amount of lost formwork needed, as well as the speed of execution. The loss of longitudinal shear resistance is, generally, the governing design mode for simply supported spans of common lengths. For common distributed loadings, the composite behaviour is influenced by the partial shear connection between the concrete and the steel sheeting. The present research work is intended to contribute to improving the ultimate limit state behaviour of composite slabs using end anchorage. Eurocode 4, Part 1.1 (EN 1994-1-1) provides an analytical methodology for predicting the increase of longitudinal resistance, achieved by using shear studs welded through the steel sheeting as the end anchorage mechanism. The code does not supply an analytical methodology for other kinds of end anchorage so, additional tests or studies are needed to prove the effectiveness of these types of anchorage. The influence of end anchorage mechanisms provided by transverse rebars at the ends of simply supported composite slabs is analysed in this paper. Two experimental programmes were carried out, the first to determine the resistance provided by the new end anchorage mechanism and the second to analyse its influence on the behaviour of simply supported composite slabs.

Removal of hexavalent chromium using modified pistachio shell

  • Parlayici-Karatas, S.;Pehlivan, E.
    • Advances in environmental research
    • /
    • 제1권2호
    • /
    • pp.167-179
    • /
    • 2012
  • Pistachio shell (Pistacia vera) (PS), a low-cost material, has been utilized for the removal of the Cr(VI) ions after treatment with citric acid. Batch experimental steps were applied to obtain Cr(VI) ion adsorption details for the equilibrium between Cr(VI) and modified pistachio shell (MPS). The influences of contact time, pH, adsorbent dose and initial chromium concentration on the adsorption performance of MPS was investigated in detail. The results displayed that adsorption of Cr(VI) by MPS reached to equilibrium after 2 h and after that a little change of Cr(VI) removal efficiency was observed. The sorption percent is higher at lower pH and lower chromium concentration. Two possible mechanisms for reduction of Cr(VI) to Cr(III) can be suggested in Cr(VI) removal. In the first mechanism, Cr(VI) is reduced to Cr(III) by surface electron-donor groups of the adsorbent and the reduced Cr(III) forms complexes with adsorbent or remains in the solution. This Cr(III) is not adsorbed by adsorbent at pH 1.8. But in second mechanism, the adsorption-coupled reduction of Cr(VI) to Cr(III) occurred on the adsorbent sites. The equilibrium sorption capacity of Cr(VI) ion after 2 h was 64.35 mg/g for MPS.