• Title/Summary/Keyword: Reduce Noise

Search Result 3,218, Processing Time 0.029 seconds

IIR Structure Secondary Path Estimation Algorithms for Active Noise Control Systems (능동소음제어를 위한 IIR 구조 2차경로 추정 알고리즘)

  • Choi, Young-Hun;Ahn, Dong-Jun;Nam, Hyun-Do
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.143-149
    • /
    • 2011
  • In this paper, IIR structures are proposed to reduce the computation complexity of the secondary-pass estimation in active noise control(ANC) systems. However, there are stability problems of using IIR models to reduce the computation complexity in ANC systems. To overcome these problems, we propose a stabilizing procedure of recursive least mean squares (RLMS) algorithms for eatimating the parameters of IIR models of the secondary path transfer functions. The multichannel ANC systems are implemented by using the TMS320C6713 DSP board to test the performance of computation complexity and stability of the proposed methods. Comparing the IIR filters with the FIR filters, the IIR filters can reduce 50[%] of the computation and obtain similar noise reduction result.

Low-cost Method for Preventing Noise from Urban Excavation Construction (도심 굴착공사에서의 소음 저감방안)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.90-95
    • /
    • 2002
  • Den have been many construction projects in urban n We have a lot of problems which have to be solved especially against residence complaints existing building damage due to construction worts. We sometimes have to pay a certain amount of cost to solve the above problem, not in planning. In addition to, we have to suffer from work delay due to confronting problem. Almost all of these are due to blasting work to break solid rock to be excavated. Therefore, this study is focused on finding out how to reduce noise more cheaply. Four cases(4) as cheaper but more effective way have been tested to find out which way of local fence will have better moise reduce function in a field site. Where five(5) large breakers are being operated. It is concluded that more form and shape of local movable panel than the site of panel can be influenced on noise reduce.

Development of a Silencer to Reduce an Interior Dailylife Noise of Apartment House (공동주택의 실내 생활소음 저감을 위한 소음기 개발)

  • Lee, Kyu-Hyung;Lee, Jang-Hyun;Kwon, Byoung-Ha;Oh, Jin-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.951-956
    • /
    • 2008
  • Development of a silencer to Reduce Noise of Cross Talking in Apartment & Stores and air conditioning to fan Composite silencer application a specific of resonant type and expansion type, design possibility at reduction frequency. This silencer test result develop reduce 20dB of specification frequency. Pressure loss 2mmAq. This silencer is special of brief structure and possibility disjoint and joint, simple installation and maintenance.

  • PDF

Narrowband Active Control of noise in thermal Power Plants using adjoint LMS algorithm (Adjoint LMS 알고리즘을 사용한 화력발전소 소음의 협대역 능동제어)

  • Hwang, Jung-Hyun;Seo, Sung-Dae;Kim, Jun-Lae;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3195-3197
    • /
    • 2000
  • Narrowband active noise control (ANC) techniques to reduce the noise in thermal power plant are considered. To reduce the computational burden of the ANC system, an adjoint LMS algorithm instead of a filteredx LMS algorithm is used for adaptive filters. The square wave signal is used for the reference signal of adaptive filters to reduce the higher order harmonics as well as the fundamental frequency of noise. A computer simulation has done to show the effectiveness of a proposed algorithm.

  • PDF

Adaptive Image Restoration of Median Filter Using Local Statistics (국부 통계를 이용한 메디안 필터의 적응 영상 복원)

  • 김남철;윤장홍;황찬식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.5
    • /
    • pp.863-867
    • /
    • 1987
  • When digital image signals are transmitted or stored, they may be usually degraded by impulsive noise such as BSC noise. Though median filtering is a very effective method to reduce the impulsive noise, it brings non-negligible distortion after filtering. Several algorithms have been proposed to reduce such a distortion, but their reconstructed image quality are inadequate in some cases and they have a difficulty in real-time processing. In this paper, an effective filtering algorithm which can not only reduce the noise effectively but also preserve the edges well and lessen the distortion greatly, is presented. The proposed algorithm is an adaptive algorithm of median filter using local statistics, based on the characteristics of human eyes. The adaptive algorithm results shwo performance improvement of up to 3-4 dB over the nonadaptive one.

  • PDF

Developing noise prediction software for Improvement of the construction noise management (공사장 소음 관리 효율화를 위한 소음예측프로그램 개발)

  • An, Jang-Ho;Lee, Jun-Seo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.155-156
    • /
    • 2009
  • Construction companies can easily understand present noise condition of their construction site via C-Noise. C-Noise is noise simulation software that simple to use. Construction companies spend time and cost for public complaints about construction noise. Construction site noise management using noise simulation software like C-Noise can reduce public complaint. achieve cost reduction to treat it.

  • PDF

Basic Study on the Performance Improvement of HD Diesel Engine (대형 디젤엔진의 소음 개선에 대한 기초 연구)

  • 김규철;이삼구;주봉철;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2001
  • The evaluation of the noise for the an existing engine was carried out to improve the current noise level. The applied techniques were 1m air-borne noise, combustion noise analysis, torsional analysis at the front pulley and sound pressure intensity. In addition, the evaluation of the possibility to the noise reduction by means of wrapping the parts was performed to propose the detailed information in engine design. In view of the obtained results, the following countermeasures were recommended to reduce the current noise level through the above methods. Furthermore, in order to assess the influence of combustion noise on the overall engine noise, the noise test was also performed by the change of intake air temperature up to 5$0^{\circ}C$ in steps of 1$0^{\circ}C$. Finally, the fixed design specifications to reduce the engine noise will be decided in consideration of the test data for proto type engine.

  • PDF

Compressor BPF noise reduction for an automotive turbocharger (차량용 터보차져의 컴프레서 BPF 소음 저감)

  • Park, Ho-Il;Eom, Sang-Bong;Seo, Ju-Bong;Lee, Seung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.851-856
    • /
    • 2012
  • Automotive turbochargers have become common in gasoline engines as well as diesel engines. They are excellent devices to effectively increase fuel efficiency and power of the engines, but they unfortunately cause several noise problems. The noises are classified into mechanical noises induced from movement of a rotating shaft and aerodynamic noises by air flow in turbochargers. The mechanical noises are whine and howling noises, and the aerodynamic noises are BPF (blade-passing frequency), pulsation, surge, some special frequency noises. These noises are bothering passengers because their levels are higher or their frequencies are clearly separated from engine or vehicle noises. The noise investigated in this paper is a BPF noise induced by compressor wheels, whose frequency is the multiplication of the number of compressor wheel blades and its rotational speed. The noise is strongly dependent upon the geometry of wheels and the number of blades. This study tried to apply a groove close to the inlet side of compressor wheels in order to reduce the BPF noise. The groove has successfully reduced the noise of narrow band frequency of a turbocharger. It shows that the groove could reduce the wide band frequency noise, the compressor BPF noise with a best shape of the groove.

  • PDF

Analysis of Noise Special Medical Examination and Work Environment Monitoring results (소음에 대한 특수건강진단 및 작업환경측정 결과 분석)

  • Kim, Kab Bae;Park, Hae Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.698-698
    • /
    • 2014
  • According to the analysis of special medical examination and work environment monitoring data, the rate of C1 and D1 on noise hazard exceeded 90% among those of total hazardous factors. The rate of company exceeding noise exposure limit was also more than 90%. The analysis result shows that main ages diagnosed with C1 and D1 was age of 50s. The majority scale company having workers diagnosed with C1 and D1 was the companies employing 5~49 workers. Types of industries which have a large number of companies exceeding noise exposure limit were automobile and trailer manufacturing, metal processing industry and primary metal manufacturing. A large number of work processes exceeding noise exposure limit were forming and processing work, cutting and bending work and grinding. To reduce the number of company exceeding noise exposure limit, the reduction counterplan should be focused on the type of industry and the work process which exceeded noise exposure limit frequently. However, the reduction counterplan is preemptively necessary to the type of industry and the work process which exceeded noise exposure limit consecutively if the purpose of reduction counterplan is not to merely reduce the number of company exceeding noise exposure limit but to abate workers' suffering from noise.

  • PDF

Floor Impact Noise Reduction Performance of Double-Floor System in Apartments (공동주택 이중바닥구조의 바닥충격음 저감성능)

  • Baek, Gil-Ok;Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.197-202
    • /
    • 2014
  • Floor Impact Noise is a structure-borne noise which is mainly caused by vibration of concrete slabs. The majority of previous studies have focused on investigating performance of absorbing sheets on the reduction of floor impact noise. But absorbing sheets do not efficiently reduce heavy-weight floor impact noise level because it cannot absorb slab vibration, which is the fundamental noise source. In this study, double-floor system was developed in order to reduce floor impact noise level in residual buildings. This floor system reduces heavy-weight impact noise level by reducing vibration response at the center of slab, which has maximum amplitude in the 1st vibration mode. In order to identify the performance of the double-floor system, experiments were planned. Primary test parameters are span of double floor, arrangement and types of absorbing sheets.

  • PDF