• 제목/요약/키워드: Recycled Coarse Aggregate (RCA)

검색결과 52건 처리시간 0.018초

Characterization of Recycled Coarse Aggregate (RCA) via a Surface Coating Method

  • Ryou, J.S.;Lee, Y.S.
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권2호
    • /
    • pp.165-172
    • /
    • 2014
  • Recycled coarse aggregate (RCA) made from waste concrete is not a suitable structural material as it has high absorption of cement mortar, which adheres on the aggregate surface and on the tiny cracks thereon. Therefore, when using RCA made from waste concrete, much water must be added with the concrete, and slump loss occurs when transporting. Hence, its workability is significantly worse than that of other materials. In this study, surface of RCA was coated with water-soluble polycarboxylate (PC) dispersant so that its characteristics improved. Each possibility was evaluated: whether its slump loss can be controlled, by measuring its workability based on the elapsed time; and whether it can be used as a structural material, by measuring its strength. Moreover, the carbonation due to cement mortar adhesion was measured through a carbonation test. As a result, RCA coated with PC dispersant was found to be better than crushed coarse aggregate and RCA when the physical properties of the fresh concrete and the mechanical, durability of the hardened concrete were tested.

Effect of using recycled coarse aggregate and recycled asphalt pavement on the properties of pervious concrete

  • Shatarat, Nasim K.;Katkhuda, Hasan N.;Hyari, Khaled H.;Asi, Ibrahim
    • Structural Engineering and Mechanics
    • /
    • 제67권3호
    • /
    • pp.283-290
    • /
    • 2018
  • This paper presents the results of a study that investigated the influence of using recycled coarse aggregate (RCA) and recycled asphalt pavement (RAP) on the properties of pervious concrete (PC). The natural aggregate (NA) was replaced by RCA and RAP in the PC with replacement levels of 0%, 20%, 40%, 60% and 80% by the total weight of NA, respectively. In addition to incorporating RAP and RCA in the same mixes with replacement levels of: (1) 20% RAP and 80% RCA; (2) 60% RAP and 40% RCA; and (3) 80% RAP and 20% RCA. Water permeability, thermal conductivity, density, porosity, void content, and compressive, splitting tensile and flexural strengths were studied in this paper. The results showed that using RCA, RAP, and (RAP-RCA) enhanced the properties of PC in general and improved the mechanical properties significantly in particular. The optimum mix was reported to be the 60% RAP and 40% RCA. Accordingly, the RAP has the potential to be used in PC in order to reduce the negative impact of RAP on the human health and environment.

5~13mm 입도분급 순환 굵은 골재 혼합사용에 따른 콘크리트의 특성평가 (Property Evaluation of the Concrete Replacing 5-13mm Recycled Coarse Aggregates)

  • 한민철;송영우
    • 한국건축시공학회지
    • /
    • 제17권1호
    • /
    • pp.55-61
    • /
    • 2017
  • 본 연구는 국내 레디믹스트 콘크리트 제조 시 57골재(5~25mm)의 경우 7번 입자(5~13mm)가 갭그레이딩되어 문제시 되는 것을 13mm 이하 RCA로 보충 해결하고자 하는 것이다. 실험 결과, 기존 레디믹스트 콘크리트용 57골재에 13mm 이하 RCA를 30%정도 혼합하여 30MPa급 콘크리트에 사용할 경우 연속입도 구현에 따른 유동성의 향상, 배합상 단위수량과 잔골재율의 감소가 가능해 압축강도를 향상시키며 건조수축을 저감시킬 수 있을 것으로 판단된다.

Assessment of reliability-based FRP reinforcement ratio for concrete structures with recycled coarse aggregate

  • Ju, Minkwan;Park, Kyoungsoo;Lee, Kihong;Ahn, Ki Yong;Sim, Jongsung
    • Structural Engineering and Mechanics
    • /
    • 제69권4호
    • /
    • pp.399-405
    • /
    • 2019
  • The present study assessed the reliability-based reinforcement ratio of FRP reinforced concrete structure applying recycled coarse aggregate (RCA) concrete. The statistical characteristics of FRP bars and RCA concrete were investigated from the previous literatures and the mean value and standard deviation were employed for the reliability analysis. The statistics can be regarded as the material uncertainty for configuring the probability distribution model. The target bridge structure is the railway bridge with double T-beam section. The replacement ratios of RCA were 0%, 30%, 50%, and 100%. From the probability distribution analysis, the reliability-based reinforcement ratios of FRP bars were assessed with four cases according to the replacement ratio of RCA. The reinforcement ratio of FRP bars at RCA 100% showed about 17.3% higher than the RCA 0%, where the compressive strength at RCA 100% decreased up to 27.5% than RCA 0%. It was found that the decreased effect of the compressive strength of RCA concrete could be compensated with increase of the reinforcement ratio of FRP bars. This relationship obtained by the reliability analysis can be utilized as a useful information in structural design for FRP bar reinforced concrete structures applying RCA concrete.

Effects of Replacement Ratio of Recycled Coarse Aggregate on the Shear Performance of Reinforced Concrete Beams without Shear Reinforcement

  • Yun, Hyun-Do;You, Young-Chan;Lee, Do-Heon
    • 토지주택연구
    • /
    • 제2권4호
    • /
    • pp.471-477
    • /
    • 2011
  • This paper will describe the experimental results on the shear behaviors of reinforced concrete (RC) beam with recycled coarse aggregate (RCA). The primary objective of this research is to evaluate the influences of different RCA replacement percentage (i.e, 0%, 30%, 60%, and 100%) on the shear performance of reinforced concrete beams without shear reinforcement. Eight large-scale RC beams without shear reinforcement were manufactured and tested to shear failure. All had a rectangular cross-section with 400mm width ${\times}$ 600mm depth and 6000mm length, and were tested with a shear span-to-depth of 5.1. The results showed that the deflection and shear strength were little affected by the different RCA replacement percentage. Actual shear strength of each RCA beam was compared with the shear strength predicted using the provisions of ACI 318 code and Zsutty'e equation for shear design of RC beams. ACI 318 code predicted the shear strength of RCA reinforced concrete beams well.

Compressive and flexural behaviour of recycled aggregate concrete filled steel tubes (RACFST) under short-term loadings

  • Yang, You-Fu;Han, Lin-Hai
    • Steel and Composite Structures
    • /
    • 제6권3호
    • /
    • pp.257-284
    • /
    • 2006
  • The behaviour of hollow structural steel (HSS) stub columns and beams filled with normal concrete and recycled aggregate concrete (RAC) under instantaneous loading was investigated experimentally. A total of 40 specimens, including 30 stub columns and 10 beams, were tested. The main parameters varied in the tests were: (1) recycled coarse aggregate (RCA) replacement ratio, from 0 to 50%, (2) sectional type, circular and square. The main objectives of these tests were threefold: first, to describe a series of tests on new composite columns; second, to analyze the influence of RCA replacement ratio on the compressive and flexural behaviour of recycled aggregate concrete filled steel tubes (RACFST), and finally, to compare the accuracy of the predicted ultimate strength, bending moment capacity and flexural stiffness of the composite specimens by using the recommendations of ACI318-99 (1999), AIJ (1997), AISC-LRFD (1999), BS5400 (1979), DBJ13-51-2003 (2003) and EC4 (1994).

순환굵은골재를 사용한 철근콘크리트 보의 휨강도 (Flexural Strength of Reinforced Concrete Beams Containing Recycled Coarse Aggregate)

  • 양인환;안슬기;황철성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권1호
    • /
    • pp.30-39
    • /
    • 2017
  • 이 연구에서는 순환굵은골재를 사용하여 31~38 MPa 범주의 압축강도를 갖는 콘크리트의 보의 휨강도 실험연구를 수행하였다. 천연굵은골재에 대한 순환굵은골재의 치환률과 철근비를 실험변수로 고려하였다. 순환굵은골재의 치환률로써 0, 30, 50 및 100%를 고려하였으며, 주철근의 철근비로써 0.50, 0.79 및 1.14%를 고려하였다. 4점 하중재하 시험방법을 통하여 순환골재 콘크리트 보의 균열 및 파괴거동, 하중-처짐 관계 특성을 파악하였다. 천연굵은골재 보와 순환굵은골재 보의 휨균열 형상은 거의 유사하며, 전반적으로 순환굵은골재 보의 균열간격이 천연굵은골재 보의 균열간격보다 작다. 순환골재치환률에 따른 균열폭 크기는 뚜렷한 차이를 나타내지 않는다. 또한, 설계기준에 의한 예측식을 이용하여 실험 부재의 휨강도를 산정하였다.현행 설계기준에 의한 순환골재 콘크리트 보의 휨강도 예측결과는 실제의 휨강도를 과소평가하여 보수적인 설계를 제공하는 것으로 나타난다.

복합이론에 의한 순환골재 콘크리트의 탄성계수 평가에 관한 기초적 연구 (A Basic Study for evaluation on the Elastic Modulus of Recycled Aggregate Concrete by using Composite Model)

  • 김현욱;김지윤;김완기;박원준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.73-74
    • /
    • 2012
  • The elastic modulus of recycled aggregate concrete (RAC) can be evaluated by using composite models with experiment. In this study, Hashin's composite model was adapted to evaluate elastic modulus considering physical properties of recycled coarse aggregate (RCA) that mortar is attached. Elastic modulus testes for cement paste, mortar and recycled coarse aggregate concrete were carried out considering W/C and recycled coarse aggregate content rate. As a result, the elastic modulus of RAC was evaluated comparing with both experiment results and the existing estimation formula. Those can be used for further studies as a preliminary data.

  • PDF

재생골재를 함유한 콘크리트의 열팽창계수 측정 (Measurement for Coefficient of Thermal Expansion of Concretes Made with Recycled Concrete Aggregates)

  • 양성철;이활웅;김남호
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.7-16
    • /
    • 2015
  • PURPOSES : This study was performed to determine a systematic approach for measuring the coefficient of thermal expansion (COTE) of concrete specimens. This approach includes the initial calibration of measurement equipment. Test variables include coarse aggregate types such as natural aggregate, job-site produced recycled concrete aggregate, and recycled aggregate processed from an intermediate waste treatment company. METHODS : First, two cylindrical SUS-304 specimens with a known COTE value of $17.3{\times}10^{-6}m/m/^{\circ}C$. were used as reference specimens for the calibration of each measurement system. The well-known AASHTO TP-60 COTE apparatus for concrete measurement was utilized in this study. Four different measurement apparatuses were used with each LVDT installed and a calibration value was determined using each measurement apparatus. RESULTS : In the initial experimental stage, calibration values for each measurement apparatus were assumed to be almost identical. However, using the SUS-304 samples as a reference, the calibration values for the four different measurement apparatuses were found to range from 3.49 to $8.86{\times}10^{-6}m/m/^{\circ}C$. Using different adjusted values for each measurement apparatuses, COTE values for the three different concrete specimens were obtained. The COTE value of concrete made with natural coarse aggregate was $9.91{\times}10^{-6}m/m/^{\circ}C$, that of job-site produced recycled coarse aggregate was $10.45{\times}10^{-6}m/m/^{\circ}C$, and that of recycled aggregate processed from the intermediate waste treatment company was $10.82{\times}10^{-6}m/m/^{\circ}C$. CONCLUSIONS : We observed that the COTE value of concrete made from recycled concrete aggregates (RCA) was higher than that of concrete made from natural coarse aggregate. This difference is due to the fact that the total volumetric mortar proportion in the RCA mix is higher than that in the concrete mix made with natural coarse aggregate.

순환골재를 사용한 SFRC 보의 전단성능 (Shear Performance on SFRC Beam Using Recycled Coarse Aggregate)

  • 김성은;정재원;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.189-196
    • /
    • 2018
  • 순환골재를 사용한 철근콘크리트 부재에서 휨강도에 비하여 전단성능 저하가 문제점으로 제기되고 있다. 이를 해결하기 위한 방법으로 강섬유를 콘크리트 보강재로 사용할 수 있다. 본 연구에서는 순환골재를 사용한 SFRC 보의 전단실험을 통하여 강도 및 변형 특성을 파악하고자 하였다. 주요 실험변수는 강섬유 혼입률(0, 0.5%, 1%), 순환골재 치환율(0%, 100%), 전단경간비(a/d = 1, 2) 등이다. 실험결과 실험에 의한 전단강도는 강섬유의 혼입률이 증가할수록 전단경간비가 작아질수록 증가하였다. 강섬유 1% 혼입한 순환골재의 경우 일반 골재에 비해 최대전단내력이 1.77~6.25% 증가한 반면에 강섬유 0~0.5% 혼입한 실험체에서는 일반골재에 비해 순환골재가 24.2%~49.2%의 전단강도가 저하되었다. 이를 볼 때 1% 강섬유 보강에 의하여 순환골재 사용에 따른 강도 저하를 방지하는데 크게 기여하는 것을 알 수 있다.