• 제목/요약/키워드: Rectifying control

검색결과 38건 처리시간 0.02초

The Characteristics on the Change of Cerebral Cortex using Alternating Current Power Application for Transcranial Magnetic Stimulation

  • Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.197-204
    • /
    • 2014
  • A transcranial magnetic stimulation device is a complicated appliance that employs a switching power device designed for discharging and charging a capacitor to more than 1 kV. For a simple transcranial magnetic stimulation device, this study used commercial power and controlled the firing angle using a Triac power device. AC 220V 60 Hz, the power device was used directly on the tanscranial magnetic stimulation device. The power supply device does not require a current limiting resistance in the rectifying device, energy storage capacitor or discharge circuit. To control the output power of the tanscranial magnetic stimulation device, the pulse repetition rate was regulated at 60 Hz. The change trigger of the Triac gate could be varied from $45^{\circ}$ to $135^{\circ}$. The AVR 182 (Zero Cross Detector) Chip and AVR one chip microprocessor could control the gate signal of the Triac precisely. The stimulation frequency of 50 Hz could be implemented when the initial charging voltage Vi was 1,000 V. The amplitude, pulse duration, frequency stimulation, train duration and power consumption was 0.1-2.2T, $250{\sim}300{\mu}s$, 0.1-60 Hz, 1-100 Sec and < 1 kW, respectively. Based on the results of this study, TMS can be an effective method of treating dysfunction and improving function of brain cells in brain damage caused by ischemia.

3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구 (The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response)

  • 박현수
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.117-122
    • /
    • 2018
  • 대용량 3상 시스템 에어컨은 최근 들어 소비 전력 저감을 위해 인버터 회로를 포함하고 있다. 인버터 회로는 교류를 다이오드를 통해 정류하고 DC-link 전원부 콘덴서에 의해 평활된 직류를 사용한다. 이 때 평활에 사용되는 DC-link 전원부 콘덴서는 전압 리플, 전류 리플 조건을 만족하기 위해 전해 콘덴서가 일반적으로 사용된다. 콘덴서의 용량을 줄이게 되면 회로부의 크기 및 무게, 비용을 줄일 수 있게 된다. 본 논문에서는 최소점 추정 PPL(Phase Locked Loop) 위상 제어와 평균 전압 d축 전류제어 기법을 조합하여 입력 리플 전류를 약 90% 저감하는 알고리즘을 제안한다. 입력 리플 전류의 감소로 인해 DC-link 콘덴서의 전류 리플도 감소하므로 콘덴서의 용량을 줄일 수 있지만 전해 콘덴서의 경우 등가 직렬 저항(ESR : Equivalent Series Resistance)이 크기 때문에 발열로 인한 수명이 한계를 가진다. 본 논문에서는 전해 콘덴서 대신 DC-link 단에 전류 리플을 고려한 필름 콘덴서를 선정하는 방법을 제안한다. 필름 콘데서의 정전 용량 선정, 내압 선정, RMS(Root Mean Square) 전류 용량, RMS 전류 주파수 해석을 고려해 콘덴서의 용량을 선정할 경우 1680uF의 전해 콘덴서를 20uF로 용량을 낮추어 설계함으로써 전원부 콘덴서의 크기 및 무게, 비용을 줄였으며 전동기 구동을 통해 동작을 확인하였다.

전기추진선박의 추진용으로 사용되는 브러시리스 직류전동기의 제 어방법에 따른 성능향상에 관한 연구 (Control Method for Performance Improvement of BLDC Motor used for Propulsion of Electric Propulsion Ship)

  • 전현민;허재정;윤경국
    • 해양환경안전학회지
    • /
    • 제25권6호
    • /
    • pp.802-808
    • /
    • 2019
  • 직류전동기는 속도제어가 간단하고, 출력 토크특성이 우수한 장점으로 윈치나 카고 펌프 모터 등으로 선박에서 많이 사용되었으며, 전기추진선박이 도입된 초기에는 선박용 추진전동기로도 적용되었다. 하지만 브러시와 정류기와 같은 기계적 정류장치의 단점으로 인해 최근에는 직류전동기와 전기적인 특성은 매우 유사하지만 기계적인 정류장치를 설치하지 않고 반도체 소자를 이용한 전자적인 정류장치를 사용하는 브러시리스 직류전동기의 사용이 증가하고 있다. 기존의 브러시리스 직류전동기를 구동하기 위한 인버터 시스템은 2상여자방식을 사용하므로 역기전력파형이 사다리꼴모양으로 되며, 이로인해 전류가 흐르는 권선이 바뀌는 상전류 전환 구간에서 고조파와 토크리플이 발생하게 된다. 이러한 고조파와 토크리플을 저감하기 위한 다양한 방안이 연구되어 발표되었으며, 본 연구에서는 전력분석프로그램을 이용하여 브러시리스 직류전동기의 구동회로에 비례적분 속도전류제어기 알고리즘을 구현한 Cascaded H-Bridge 멀티레벨 인버터를 적용하였다. 모델링한 브러시리스 직류전동기의 시뮬레이션을 통해 제안하는 전동기의 구동방식을 적용하는 경우에 기존의 구동방식에 비해 전동기 입력측 전압파형 개선과 고조파 및 토크리플이 현저히 저감되는 결과를 확인할 수 있었다.

Achievements, Problems, and Future Direction of the Quality Control Program for Special Periodic Health Examination Agencies in Republic of Korea

  • Won, Yong Lim;Ko, Kyung Sun;Park, Jae Oh;Choi, Yoon jung;Lee, Hyeji;Sung, Jung-min;Lee, Mi-young
    • Safety and Health at Work
    • /
    • 제10권1호
    • /
    • pp.125-129
    • /
    • 2019
  • The ultimate goal of the quality control program for special periodic health examination agencies is to diagnose the health condition of a worker correctly, based on accurate examination and analysis skills, leading to protect the worker's health. The quality control program on three areas, chemical analysis for biological monitoring since 1995, and pneumoconiosis, audiometric testing since 1996, has contributed to improve the reliability of occupational health screenings by improving the issues including standardization of testing methods, tools, diagnostic opinions, and reliability of analysis for biological monitoring. It has contributed to improving the reliability of occupational health monitoring by rectifying the following issues associated with previous monitoring: absence of standardized testing methods, testing tools that are not upgraded, mismatching diagnostic opinions, and unreliable results of biological specimen analysis. Nevertheless, there are issues in need of further improvement such as lack of expertise or the use of inappropriate method for health examination, and passive and unwilling participation in the quality control. We suggested solutions to these problems for each area of quality control program. Above all, it is essential to provide active support for health examiners to develop their expertise, while encouraging all the health screening agencies, employers, and workers to develop the desire to improve the system and to maintain the relevance.

Si 기판에서의 광소자 응용을 위한 Ge 박막의 Transfer 기술개발 (Ge thin layer transfer on Si substrate for the photovoltaic applications)

  • 안창근;조원주;임기주;오지훈;양종헌;백인복;이성재
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.743-746
    • /
    • 2003
  • We have successfully used hydrophobic direct-wafer bonding, along with H-induced layer splitting of Ge, to transfer 700nm think, single-crystal Ge films to Si substrates. Optical and electrical properties have been also observed on these samples. Triple-junction solar cell structures gown on these Ge/Si heterostructure templates show comparable photoluminescence intensity and minority carrier lifetime to a control structure grown on bulk Ge. When heavily doped p$^{+}$Ge/p$^{+}$Si wafer bonded heterostructures were bonded, ohmic interfacial properties with less than 0.3Ω$\textrm{cm}^2$ specific resistance were observed indicating low loss thermal emission and tunneling processes over and through the potential barrier. Current-voltage (I-V) characteristics in p$^{+}$Ge/pSi structures show rectifying properties for room temperature bonded structures. After annealing at 40$0^{\circ}C$, the potential barrier was reduced and the barrier height no longer blocks current flow under bias. From these observations, interfacial atomic bonding structures of hydrophobically wafer bonded Ge/Si heterostructures are suggested.ested.

  • PDF

Supporter to Rectifying the Asymmetric Sitting Posture of Post Stroke

  • Lee, In-Hee;Choi, Jin-Ho;Park, Sang-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제23권3호
    • /
    • pp.43-47
    • /
    • 2011
  • Purpose: This study determined the best adjustable height supporter for stroke patients in wheelchairs for the maintenance of a symmetric sitting posture. Methods: Thirty-one stroke participants and 20 age-matched control participants were recruited. The enrolled participants were evaluated by the Force Sensitive Application (FSA) System that was used to assess weight shift and symmetry in wheelchair sitting and assess the symmetric index (SI) of subjects according to 1, 2 and 3 cm height supporters. Results: When a 1 cm height supporter was applied to the paretic side of stroke survivors, sitting postures of stroke patients were significantly more symmetrical (p<0.01). Cross tabulation between the SI of wheelchair sitting and that of the paretic side of stroke patients caused? by a 1 cm supporter showed that 21 SIs of 26 stroke patients were improved by a 1 cm supporter to the paretic side (k=0.26, p<0.01). Conclusion: The findings of the present study demonstrate that stroke patients can maintain a more symmetrical sitting posture (than is possible when simply sitting in a wheelchair seat) if a 1 cm supporter is applied to the paretic side of stroke patients.

200-MW 모듈레이터의 동작 특성 및 고조파 해석 (Operation Characteristic and Harmonic Analysis of 200-MW Modulator)

  • 박성수;오종석;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Neonatal Diabetes Mellitus Due to KCNJ11 (KIR6.2) Mutation Successfully Treated with Sulfonylurea

  • Jang, Sehun;Yang, Misun;Ahn, So Yoon;Sung, Se In;Chang, Yun Sil;Park, Won Soon
    • Neonatal Medicine
    • /
    • 제28권2호
    • /
    • pp.94-98
    • /
    • 2021
  • Neonatal diabetes mellitus (NDM) is a rare disease that occurs at less than 6 months of age and is presumably caused by a mutation in the gene that affects pancreatic beta-cell function. Approximately 80% of NDM cases reveal a known genetic mutation, and mutations in potassium inwardly rectifying channel subfamily J member 11 (KCNJ11) and ABCC8 affecting the pancreatic beta-cell adenosine triphosphate-sensitive potassium channel may be treated with oral sulfonylurea. Early recognition of mutations in KCNJ11 and ABCC8 is important because early administration of sulfonylurea can not only control blood glucose levels but also improve neurodevelopmental outcomes. In the present study, we report a case of NDM that initially presented as diabetic ketoacidosis at the age of 1 month, accompanied by seizures during hospitalization. After confirmation of the KCNJ11 gene mutation (c.989A>C), we started administering oral sulfonylurea (glimepiride) at the age of 2 months. After gradually increasing the dosage of glimepiride, insulin was discontinued at the age of 3 months. To date, the infant's blood glucose levels have been well controlled without significant hypoglycemic events. No further episodes of seizures have occurred, and his developmental status is favorable.

전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터 (Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor)

  • 천창근;김철우
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.105-112
    • /
    • 2003
  • AC/DC 전력변환장치로서 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기는 역률저하 및 저차고조파 발생의 문제점을 가진다. 본 논문에서는 역률개선 및 고조파 감소의 문제점을 극복하기 위하여 3상 PWM AC/DC Boost 컨버터에 대해 연구하였다. 제안한 컨버터의 특성은 입력 단에 전류 센서 없이 전압 센서만을 사용하여 입력전류의 위상을 조정하는 비교적 간단한 알고리즘으로 단위역률을 구현하였으며, 일정 주파수로 스위칭 소자를 구동시키는 정현 PWM 방식을 채용하여 불규칙한 스위칭 주파수 방식에서 나타나는 입력필터의 설계 및 스위칭 소자 선정에 대한 어려움을 극복하였다. 본 논문에서 제안한 제어알고리즘을 시뮬레이션 한 결과 부하영역 및 발전영역에서도 단위역률이 잘 이루어졌으며 DC link 단의 출력전압이 거의 리플 없이 다이나믹한 응답특성을 보였다. 또 시뮬레이션으로 얻어진 회로정수를 바탕으로 인덕터 및 커패시터의 용량을 적절한 크기로 산정하여 실험 에 적용한 결과 같은 부하조건에서 다이오드 정류기와 비교하여 역률 및 저차 고조파가 현저하게 개선되었음을 알 수 있었다.

[$Ca^{2+}$ Signalling in Endothelial Cells: Role of Ion Channels

  • Nilius, Bernd;Viana, Felix;Kamouchi, Masahiro;Fasolato, Cristina;Eggermont, Jan;Droogmans, Guy
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권2호
    • /
    • pp.133-145
    • /
    • 1998
  • $Ca^{2+}-signals$ in endothelial cells are determined by release from intracellular stores and entry through the plasma membrane. In this review, the nature of $Ca^{2+}$ entry and mechanisms of its control are reviewed. The following ion channels play a pivotal role in regulation of the driving force for $Ca^{2+}$ entry: an inwardly rectifying $K^+$ channel, identified as Kir2.1, a big-conductance, $Ca^{2+}-activated$ $K^+$ channel (hslo) and at least two $Cl^-$ channels (a volume regulated $Cl^-$ channel, VRAC, and a $Ca^{2+}$ activated $Cl^-$ channel, CaCC). At least two different types of $Ca^{2+}$-entry channels exist: 1. A typical CRAC-like, highly selective $Ca^{2+}$ channel is described. Current density for this $Ca^{2+}$ entry is approximately 0.1pA/pF at 0 mV and thus 10 times smaller than in Jurkat or mast cells. 2. Another entry pathway for $Ca^{2+}$ entry is a more non-selective channel, which might be regulated by intracellular $Ca^{2+}$. Although detected in endothelial cells, the functional role of trp1,3,4 as possible channel proteins is unclear. Expression of trp3 in macrovascular endothelial cells from bovine pulmonary artery induced non-selective cation channels which are probably not store operated or failed to induce any current. Several features as well as a characterisation of $Ca^{2+}$-oscillations in endothelial cells is also presented.

  • PDF