• Title/Summary/Keyword: Rectangular plan

Search Result 80, Processing Time 0.022 seconds

Typomorphological Study on Open-rectangular plan Hanok in the Traditional Urban Housing Neighborhood of Bukchon, Seoul (북촌 튼ㅁ자형한옥의 유형연구)

  • Song, In-Ho
    • Journal of architectural history
    • /
    • v.13 no.4 s.40
    • /
    • pp.125-138
    • /
    • 2004
  • Open-rectangular plan Hanok is one of the major types that compose the urban tissues of Bukchon, a typical traditional residential area in Seoul. Through the comparison of the cadastral map of 1912 and the aerial photograph of 1962, the paper has given the outline of the and the distribution of Open-rectangular plan Hanok at Bukchon. And the paper defines the characteristics of Open-rectangular plan Hanok at Bukchon as followings. First, Open-rectangular plan Hanok at Bukchon is the mutated type of Open-rectangular plan Hanok in Kyong-gi Province. Second, the composition and characteristics of Bakat-chae and outer-courtyard have been changed through the adaptation itself to the compact lots of urban neighborhood. Third, the composition and characteristics of An-chae has not been changed except the inner corner bay, that gives the lights and view to An-bang through the window. And the comparison and observation of four examples, the paper defines the identities of Open-rectangular plan Hanok at Bukchon. The partial transformation comes from the conflicts and adjustments with the structure of alley and the topographical condition of lots.

  • PDF

A Study on the Structure of Combined Architecture of Dang and Sil in the Early Joseon Dynasty -Focusing on the Rectangular Plan and the Gable Roof Meeting at Right Angle- (조선전기 당(堂)·실(室) 결합 건축의 가구특성 분석 -방형 평면의 맞배직교형 지붕 가구를 중심으로-)

  • Kim, Bue-Dyel;Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.26 no.2
    • /
    • pp.31-42
    • /
    • 2017
  • This study investigates how the spatial recognition structure is emerging through the case of rectangular plan combined with a combination of Dang-Sil(堂室) and Gong(工) shape roof, and identifies a type of architecture in the early Joseon Dynasty that has never been revealed. The conclusion of this study is as follows. First, the Dang and the Sil are connected to each other, but the architectural elements such as pillars, frame, and windows are distinguished and appear as separate buildings. Second, the distinction between Dang and Sil is evident by the difference in the number of ridges and the shape of the roof. In addition, the roof and roof framework of the independent rooms and the rooms were common in the right angled architecture where the direction and the expandability of each structure were maintained. Third, the construction of the Dang-Sil combined structure, in which two or more structure frameworks were combined with the rectangular combined flat roof structure, gradually changed into a single structure with a single ridge. Fourth, this change means that people of the early Joseon Dynasty recognized the Dang and Sil as separate architecture, but the strict sense of spatial separation has disappeared over time.

presumption of Earth Resistance by Water Tank Model (수조모델 실험에 의한 접지저항 추정)

  • 고희석;최종규;김주찬;이충식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.125-131
    • /
    • 2002
  • It is very important to assume potential distribution to be generated in electrode environs and grounding resistance by current beforehand, when incoming at grounding electrode to plan efficient grounding facilities In this paper, we analyzed grounding resistance through a simulation experiment by a water tank scaled model electrode of the rectangular earth plate, a theoretical Calculation result of the rectangular earth plate and measurement of grounding resistance buried rectangular earth plate analysing earth surface potential.

  • PDF

An Analytic Study on the Bond Stress between Concrete and Steel Tube in CFT Rectangular Column (충전각형강관기둥에서 콘크리트와 강관의 부착응력에 관한 해석적 연구)

  • Park, Sung-Moo;Kang, Joo-Won;Kim, Won-Ho;Lee, Hyung-Seok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.4 s.6
    • /
    • pp.53-60
    • /
    • 2002
  • An analytic study on the bond stress between steel tube and concrete in concrete filled steel(CFT) rectangular column is presented in this paper. Recently buildings need members which are enhanced durability and ductility. Concrete filled rectangular column system is proposed as alternative plan. In this paper, ABAQUS/Standard Version 5.8 which is identified as usefulness for finite element analysis and has various element library is used. The variables in this study are the location and type of shear-connector. The modeling on contact problem practiced by Contact Pair and Contact Pressure method. In the step of physical bond, it is practiced by Change friction option After yielding of models, analytic results is less than that of experimental results.

  • PDF

A Study on the Changes of the Plan Type of Protestant Church Architecture in Korea - Focused on the distinction between the sexes(男女有別) and the seat position of the sexes - (한국 개신교 교회건축의 평면형태 변천 연구 - '남녀유별' 관념과 회중석의 남녀 위치를 중심으로 -)

  • Lee, Hee-Jun;Yoon, In-Suk
    • Journal of architectural history
    • /
    • v.14 no.3 s.43
    • /
    • pp.129-148
    • /
    • 2005
  • The plan type of Korean protestant church architecture underwent changes as following five stages according to the changes of the distinction between the sexes. First stage - At the beginning of missionary work in Korea, Koreans generally worshiped in missionary houses which were traditional Korean styles. The plan type of these houses was a simple '-' figure. At that time, men and women worshiped separately because of the idea of the distinction between the sexes. They either worshiped in different places at the same time or in the same place at the different time. Second stage - At this stage, men and women started to worship together in the same place. At the beginning of this stage, men sat in the front of the chapel on a rostrum, and women sat behind the men. The plan type of the chapel was a simple '-' or a rectangular figure. Later, they sat separately on the right and left side. There are the visual interceptions which were set up between them. As the number of church members increased rapidly, a new type of church architecture appeared. It was a 'ㄱ' figure. At that time the entrances were separated by the sexes. Third stage - At this stage, the visual interceptions disappeared as the idea of the distinction between the sexes became weak. As new churches had been constructed by the plan type of rectangular figure, the visual interceptions weren't set up anymore. Fourth stage - At this stage, the separated entrances were unified as one. But the arrangement of their seats didn't change because of the old idea of the distinction between the sexes. Fifth stage - In the final stage, the plan type of the church architecture was not determined by the idea of the distinction between the sexes but social, economical, technological facts and the influence of the foreign architecture. At this stage, new and various kinds of the plan type appeared such as the fan, round, squared, or oval figure as well as the rectangular figure. Men and women were not classified anymore. They started to sit and worship together in the same place. Also, when men and women sat separately from side to side because of the Idea of the distinction between the sexes, men sat on the right and women sat on the left side of rostrum. It didn't applied Confucian ideas but the idea of protestant church; protestant churches have the idea that the right side is more important but it does not in Confucianism.

  • PDF

A Study on the Inland Signal-fire in Chosun Dynasty (조선시대 내지봉수에 관한 연구)

  • Yoon, Jae-Woong;Lee, Chul-Young
    • Journal of architectural history
    • /
    • v.18 no.6
    • /
    • pp.47-64
    • /
    • 2009
  • This research was to analyze the inland signal-fire which is the main facility of military protective duty for safety of land in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, oval, rectangular, indeterminate form. The majorities were oval type. 2. Plan configuration of brazier which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of brazier was about 3~4.5m. The diameter of brazier was 1.5~2.5m. Building base that protect ground moisture and infilteration of rainfall was found in 5 inland singal-fire, the height of it was about 0.3m~2.5m. 3. The heigh to protective wall remained until present was about 1m, the depth was about average 1.2m. 4. Entrance was mainly stairs or open type and average width was 1.0~1.2m. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 5. The storage of inland signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the brazier.

  • PDF

Static analysis of singly and doubly curved panels on rectangular plan-form

  • Bahadur, Rajendra;Upadhyay, A.K.;Shukla, K.K.
    • Steel and Composite Structures
    • /
    • v.24 no.6
    • /
    • pp.659-670
    • /
    • 2017
  • In the present work, an analytical solution for the static analysis of laminated composites, functionally graded and sandwich singly and doubly curved panels on the rectangular plan-form, subjected to uniformly distributed transverse loading is presented. Mathematical formulation is based on the higher order shear deformation theory and principle of virtual work is applied to derive the equations of equilibrium subjected to small deformation. A solution methodology based on the fast converging finite double Chebyshev series is used to solve the linear partial differential equations along with the simply supported boundary condition. The effect of span to thickness ratio, radius of curvature to span ratio, stacking sequence, power index are investigated. The accuracy of the solution is checked by the convergence study of non-dimensional central deflection and moments. Present results are compared with those available in the literature.

A Study on the Feature of Plan Type and Space Composition of the Siheyuan Housing in China (중국 사합원의 평면유형과 공간구성의 특징에 관한 개괄적 연구)

  • 최장순
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.19-26
    • /
    • 2003
  • The purpose of this paper is to examine and analyse the features of plan type and space composition of the Siheyuan(courtyard house) which is one of the most remarkable types of the traditional dwellings in China. With the passage of time this house developed into one of the chinese house style. The technique of Siheyuan's spatial composition goes so far back in the New Stone Age. The relics of this are the colony layout, the system of four sides, the layout type of a palace, the picture of lacquered ware, the pictured brick, the earthenware of house type, the cave painting, the paintings of painters and others. The fundamental spatial conception of it arranges one or more courtyards to compose, sometimes in a very complex way, a general walled compound. The main longitudinal axis is mainly north-south, but the chief buildings, or halls are always placed transversely to it. These rectangular buildings mayor may not connect, by means of open galleries variously planned, with rows of smaller buildings flanking the courtyards on both sides. On this system, enlargement is never carried out by adding to height, but by continual duplication of existing units, and growth in breadth or preferably depth. The need for family security is thought to have led to the development of this rectangular houses with walls mainly blank on the outside, defensible entrances, and public service facilities in the center of the houses.

Efficient models for analysis of a multistory structure with flexible wings

  • Moon, Seong-Kwon;Lee, Dong-Guen
    • Structural Engineering and Mechanics
    • /
    • v.13 no.5
    • /
    • pp.465-478
    • /
    • 2002
  • This study lays emphasis on the development of efficient analytical models for a multistory structure with wings, including the in-plane deformation of floor slabs. For this purpose, a multistory structure with wings is regarded as the combination of multistory structures with rectangular plan and their junctions. In addition, a multistory structure with a rectangular plan is considered to be an assemblage of two-dimensional frames and floor slabs connecting two adjacent frames at each floor level. This modeling, concept can be easily applied to multistory structures with plans in the shape of L, T, Y, U, H, etc. To represent the in-plane deformation of floor slabs efficiently, a two-dimensional frame and the floor slab connecting two adjacent frames at each floor level are modeled as a stick model with two degrees of freedom per floor and a stiff beam with shear deformations, respectively. Three models are used to investigate the effect of in-plane deformation of the floor slab at the junction of wings on the seismic behavior of structures. Based on the comparison of dynamic analysis results obtained using the proposed models and three-dimensional finite element models, it could be concluded that the proposed models can be used as an efficient tool for an approximate analysis of a multistory structure with wings.

A Study on the Border Signal-fire In Eastern Sea (조선시대 동해안지역 연변봉수에 관한 연구)

  • Lee, Chul-Young;Kim, Seong-Chul
    • Journal of architectural history
    • /
    • v.17 no.2
    • /
    • pp.47-66
    • /
    • 2008
  • This research was to analyze the border signal-fire which is the main facility of military protective duty for safety of sea side in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, half-circle, oval, round-rectangular. The majorities were circle type in eastern area. 2. Plan configuration of signal-fire stand which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of signal-fire stand was about $2{\sim}3m$. The diameter of signal-fire stand was $8{\sim}10m$. Building base that protect ground moisture and infilteration of rainfall was found in 9 border singal-fire, the height of it was about $0.3m{\sim}2.5m$. 3. Trench was mainly circle type and average width was $3{\sim}4m$. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 4. The height of protective wall remained until present was about 1m, the depth was about average 2.5m. 5. The storage of border signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the signal-fire stand.

  • PDF