• Title/Summary/Keyword: Rectangular Coil

Search Result 66, Processing Time 0.026 seconds

A CASE OF PALATALLY IMPACTED INCISOR TREATED BY ONLAY TECHNIQUE WITH SURGICAL EXPOSURE (Onlay technique에 의한 매복중절치의 교정적 치험예)

  • Kim, Kwang-Hyun;Choie, Mok-Kyun;Bae, Chang
    • The korean journal of orthodontics
    • /
    • v.4 no.1
    • /
    • pp.57-61
    • /
    • 1974
  • The patient, a girl of 19 years in good health, had a class I malocclusion. The maxillary left centra1 incisors and both lateral incisors had already erupted. But the space for the right central incisor was partially closed by the mesial drifting of the neighboring teeth. The caused a shift in the midline and a cross-bite relation on the incisors. X-ray examination revealed the presence of the right central incisor in the alveolar bone and odontoma just above the crown of the right central incisor. After enough space for the impacted incisor was created in the dental arch with a open-coil spring the rectangular incision was made. Removing the odontoma uncovered the flat surface of the labial aspect of the incisor. During the tooth had erupted of its own accord, any unnecessary force had been imposed on the tooth. When it was decided that the tooth should be brought out by the mechanical device, the gold cast onlay with hook was used and run a light elastic between this hook and the main arch wire. Finally the tooth was brought down to the arch level. The result was excellent. Fortunately the esthetic problem and any detrimental effects on the psychological make-up could be avoided.

  • PDF

Development of Electronic Compass Using 2-Axis Micro Fluxgate Sensor (2축 마이크로 플럭스게이트 센서 제작을 통한 전자 나침반 개발)

  • 박해석;심동식;나경원;황준식;최상언
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.418-423
    • /
    • 2003
  • This paper describes an electronic compass using micromachined X- and Y-axis micro fluxgate sensors which were perpendicularly aligned each other to measure X- and Y-axis magnetic fields respectively. The fluxgate sensor was composed of rectangular-ring shaped magnetic core and solenoid excitation(49 turns) and pick-up(46 turns) coils. Excitation and pick-up coil patterns which were formed opposite to each other wound the magnetic core alternatively to improve the sensitivity and to excite the magnetic core in an optimal condition with reduced excitation current. The magnetic core has DC effective permeability of ~1000 and coercive field of ~0.1 Oe. The magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. To decrease the difference of induced second harmonic voltages from X- and Y-axis, excitation condition of 2.8 $V_{P-P}$ and 1.2 MHz square wave was selected. Excellent linear response over the range of -100 $\mu$T to +100 $\mu$T was obtained with 210 V/T sensitivity. The size of each micro fluxgate sensor excluding pad region was about 2.6${\times}$1.7 $mm^2$ and the power consumption was estimated to be 14 mW.W.

Fabrication of Planar Type Inductor Using FeTaN Magnetic thin Films

  • Kim, Chung-Sik;Seok Bae;Jeong, Jong-Han;Nam, Seoung-Eui;Kim, Hyoung-June
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.532-538
    • /
    • 2000
  • A double rectangular spiral inductor is fabricated using FeTaN films. The inductor is composed of internal coils sandwiched by magnetic layers. Characteristics of inductor performance are investigated with an emphasis on planarization of magnetic films. In the absence of the planarization process, the grating topology of upper magnetic films over coil arrays degrades the soft magnetic properties and the inductor performance. It also induces a longitudinal magnetic anisotropy with the easy axis aligned to the magnetic flux direction. This alignment prevents the upper magnetic films from contributing to the total induction. Glass bonding is a viable method for achieving a completely planar inductor structure. The planar inductor with glass bonding shows excellent performance : inductance of 1.1 H, Q factor of 7 (at 5 MHz), and the dc current capability up to 100 mA.

  • PDF

Study on the Air Bearings with Actively Controllable Magnetic Preloads for an Ultra-precision Linear Stage (초정밀 직선 이송계용 능동 자기예압 공기베어링에 관한 연구)

  • Ro, Seung-Kook;Kim, Soo-Hyun;Kwak, Yoon-Keun;Park, Chun-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.134-142
    • /
    • 2008
  • In this paper, we propose a precise linear motion stage supported by magnetically preloaded air bearings. The eight aerostatic bearings with rectangular carbon porous pads were located only one side of vertical direction under the platen where four bearings are in both sides of horizontal direction as wrap-around-design, and this gives simpler configuration than which constrained by air bearings for all direction. Each of the magnetic actuators has a permanent magnet generating static magnetic flux far required preload and a coil to perturb the magnetic farce resulting adjustment of air- bearing clearance. The characteristics of porous aerostatic bearing are analyzed by numerical analysis, and analytic magnetic circuit model is driven for magnetic actuator to calculate preload and variation of force due to current. A 1-axis linear stage motorized with a coreless linear motor and a linear encoder was designed and built to verify this design concept. The load capacity, stiffness and preload force were examined and compared with analysis. With the active magnetic preloading actuators controlled with DSP board and PWM power amplifiers, the active on-line adjusting tests about the vertical, pitching and rolling motion were performed. It was shown that motion control far three DOF motions were linear and independent after calibration of the control gains.

A Study on the Characteristic Evaluation of An HTS Coil with respect to the Winding Methods

  • Jo, Hyun-Chul;Choi, Suk-Jin;Jang, Jae-Young;Hwang, Young-Jin;Lee, Chang-Young;Ahn, Min-Cheol;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.31-35
    • /
    • 2010
  • In superconducting magnet applications, winding methods of the superconducting magnet can be classified into a layer winding and a pancake winding. The superconducting magnet using high temperature superconductor (HTS) with rectangular shape is generally fabricated using the pancake winding method. On the other hand, low temperature superconducting (LTS) magnet may be wound by either a pancake winding or a layer winding. Compared with the layer winding, the pancake winding method has a merit of easy replacement of a damaged pancake module, but it also has a demerit of requirement of splicing between each double pancake modules. In this paper, we investigated characteristics of the layer and pancake winding methods using HTS. Six samples were wound out of BSCCO and Coated Conductors (CCs) by two winding methods and their characteristics were experimentally observed.

Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement (저전도율 유체 측정에서 소형 전자기유량계의 신호 특성)

  • Lim, Ki Won;Jung, Sung Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.613-620
    • /
    • 2016
  • In order to scrutinize the fluid conductivity effects on the electromagnetic flowmeter(EMF) characteristics, a small scale EMF was designed and fabricated. The measuring tube has a $3mm{\times}4mm$ rectangular cross-section, 9 mm length, and a $2mm{\times}3mm$ plate electrode and a ${\Phi}1.5mm$ point electrode. The design parameters, such as the magnetizing frequency and the number of coil turns, and the diameter were optimized. The EMF was tested with a gravimetric calibrator and showed good linearity in the range of 0 to $1.17{\times}10^{-5}m^3/s$. The fluid conductivity was varied between 3 and $11{\mu}S/cm$, and the magnitude of the flow signal was proportional to the fluid conductivity and the wetted area of the electrode. The design information and the test results provide flow measurement techniques for very low flowrate.