• 제목/요약/키워드: Recovery technology

검색결과 3,155건 처리시간 0.037초

Energy Management of a Grid-connected High Power Energy Recovery Battery Testing System

  • Zhang, Ke;Long, Bo;Yoo, Cheol-Jung;Noh, Hye-Min;Chang, Young-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.839-847
    • /
    • 2016
  • Energy recovery battery testing systems (ERBTS) have been widely used in battery manufactures. All the ERBTS are connected in parallel which forms a special and complicated micro-grid system, which has the shortcomings of low energy recovery efficiency, complex grid-connected control algorithms issues for islanded detection, and complicated power circuit topology issues. To solve those shortcomings, a DC micro-grid system is proposed, the released testing energy has the priority to be reutilized between various testing system within the local grid, Compared to conventional scheme, the proposed system has the merits of a simplified power circuit topology, no needs for synchronous control, and much higher testing efficiency. The testing energy can be cycle-used inside the local micro-grid. The additional energy can be recovered to AC-grid. Numerous experimental comparison results between conventional and proposed scheme are provided to demonstrate the validity and effectiveness of the proposed technique.

Mucosal mast cell responses in the small intestine of rats infected with Echinostoma hortense

  • Kim, In-sik;Im, Jae-Aee;Lee, Kyu-Je;Ryang, Yong-Suk
    • Parasites, Hosts and Diseases
    • /
    • 제38권3호
    • /
    • pp.139-143
    • /
    • 2000
  • Mucosal mast cell (MMC) responses and worm recovery rates in rats infected with Echinostona hortense were investigated from day 3 to day 56 post-infection (p.i.). Experimental infected group showed apparently higher number of MMC in each part of the small intestine than that of the control group. The number of MMC in the duodenum increased gradually after the infection and reached a peak on day 35 p.i. Thereafter, the number of MMC continued to decrease at a slow pace. The kinetics of MMC responses in the upper and lower jejunum were similar to that of the duodenum, but the number of MMC in the jejunum was lower. The worm recovery rate decreased with respect to time of which it was markedly reduced on day 49 and 56 p.i. The duration in which a high number of MMC appeared was similar to that in which a low rate in worm recovery was recorded . These results indicate dlat intestinal mastocytosis may play an important role in the expulsion of 5. hortense.

  • PDF

Deep Learning based Loss Recovery Mechanism for Video Streaming over Mobile Information-Centric Network

  • Han, Longzhe;Maksymyuk, Taras;Bao, Xuecai;Zhao, Jia;Liu, Yan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권9호
    • /
    • pp.4572-4586
    • /
    • 2019
  • Mobile Edge Computing (MEC) and Information-Centric Networking (ICN) are essential network architectures for the future Internet. The advantages of MEC and ICN such as computation and storage capabilities at the edge of the network, in-network caching and named-data communication paradigm can greatly improve the quality of video streaming applications. However, the packet loss in wireless network environments still affects the video streaming performance and the existing loss recovery approaches in ICN does not exploit the capabilities of MEC. This paper proposes a Deep Learning based Loss Recovery Mechanism (DL-LRM) for video streaming over MEC based ICN. Different with existing approaches, the Forward Error Correction (FEC) packets are generated at the edge of the network, which dramatically reduces the workload of core network and backhaul. By monitoring network states, our proposed DL-LRM controls the FEC request rate by deep reinforcement learning algorithm. Considering the characteristics of video streaming and MEC, in this paper we develop content caching detection and fast retransmission algorithm to effectively utilize resources of MEC. Experimental results demonstrate that the DL-LRM is able to adaptively adjust and control the FEC request rate and achieve better video quality than the existing approaches.

Comparative study on one and two-path single energy recovery circuit for plasma display panel (PDP)

  • Yi, Kang-Hyun;Choi, Seong-Wook;Moon, Gun-Woo;Park, Jung-Pil;Jung, Nam-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.256-259
    • /
    • 2006
  • Comparison of one two-path single energy recovery circuit for plasma display panel (PDP) is shown in this paper. A single energy recovery circuit (SERC) is proposed to reduce cost for manufacturing PDP and there are two ways, one and two-path, in driving this circuit. Compared with one-path SERC, there are low power consumption, low surge current and high performance in two-path SERC. The results will be shown with 42-inch HD panel.

  • PDF

Alkaline Protease of a Genetically-Engineered Aspergillus oryzae for the Use as a Silver Recovery Agent from Used X-Ray Film

  • Samarntarn, Warin;Morakot Tanticharoen
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권5호
    • /
    • pp.568-571
    • /
    • 1999
  • Aspergillus oryzae U1521, which was a genetically engineered strain, produced 1,000,600 U per g . glucose of extracellular alkaline protease within 72 h in a submerged fermentation. However, the alkaline protease was not detected during the first 24 h. Northern blot analysis indicated that the enzyme synthesis was repressed at the transcriptional level during the lag period. Both catabolite repression and pH of the growth medium significantly affected the enzyme production. Use of this enzyme as a silver recovery agent from used X-ray film was confirmed by experiments in the shake-flask scale.

  • PDF

An Improved Soft Switching Bi-directional PSPWM FB DC/DC Converter

  • Kim, Eun-Soo;Joe, Kee-Yeon;Kim, Yoon-Ho;Cho, Yong-Hyun;Choi, Won-Beom
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1042-1046
    • /
    • 1998
  • A new soft switching isolated bi-directional phase shifted pulse width modulation (PSPWM) dc/dc converter is presented. Due to the use of the energy recovery snubber, the isolated bi-directional PSPWM dc/dc converter has a significant reduction of switching losses in the switching devices of the primary and secondary side bridge, respectively. The proposed soft switching bi-directional PSPWM FB dc/dc converter provides an energy recovery snubber which consists of two fast recovery diodes, a resonant capacitor and a resonant inductor. The complete operating principles and simulation results will be presented.

  • PDF

Dual 컨버터로 동작하는 새로운 ZCS PWM Boost Converter (A New ZCS PWM Boost Converter with operating Dual Converter)

  • 김태우;진기호;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.525-528
    • /
    • 2002
  • A Novel Zero Current Switching(ZCS) Pulse Width Modulation(PWM) boost converter for reducing two rectifiers reverse recovery related losses Is proposed. The switches of the proposed converter are operating to work alternatively turn-on and turn-off with soft switching(ZVS, ZCS) condition. The reverse recovery related switching losses and EMI problems of the proposed converter eliminates the reverse recovery current of the freewheeling diode(D, Dl) by adding the resonant inductor Lr, in series with the switch S2. The voltage and current stresses of the components are similar to those in its conventional hard switching counterpats. As mentioned above, the characteristics are verified through experimental results.

  • PDF

Regeneration of solid phase filter by chemical cleaning

  • Byung-Dae Lee
    • 한국응용과학기술학회지
    • /
    • 제41권1호
    • /
    • pp.19-26
    • /
    • 2024
  • Recently, separation membranes have been applied to fields such as water supply, sewage treatment, gray water reuse, and air pollution control. Chemical cleaning technology is attracting attention among the methods of reusing these expensive separation membranes. It was found that the separation membrane could be regenerated using chemical cleaning. Specifically, it was found that the use time of the separation membranes regenerated by chemical cleaning was sustainable for more than 1,700 hours. Additionally, it was found that the flux recovery ratio after chemical cleaning was maintained at least 60%. In addition, the flux recovery ratio of HYDREX 4710, an organic membrane cleaner, and 4703, an inorganic membrane cleaner, was 76% and 62%, respectively, showing the highest flux recovery ratio among the chemicals used. Considering that the target raw water of this study is biological secondary treatment water, it was suggested that chemical cleaning could be actively used to regenerate separation membranes in future water treatment.

반응표면 분석법을 이용한 Papaya 유액추출물에서 Crude Protein 회수 조건의 최적화 (Optimization of Crude Protein Recovery from Papaya Latex Extract Using Response Surface Methodology)

  • 오훈일;오상준;김정미
    • 한국식품과학회지
    • /
    • 제29권4호
    • /
    • pp.752-757
    • /
    • 1997
  • Papaya 유액 추출물에서 protein을 정제 회수하기 위해 papaya 유액으로부터 추출한 추출액을 경제적이고도 처리가 비교적 간단한 ethanol 침전방법을 사용하였다. 실험계획법에 의하여 설정된 3수준의 부분요인 실험법에 의하여 실시된 각 처리구의 실험 결과를 다중 회귀분석 방법에 의해 다음과 같은 모델식 $Y=7.4554+1.2657X_{2}+1.0552X_{3}-1.7407X_{4}-0.01666X_{2}\;^{2}-0.1134X_{4}^{2}$을 산출하였으며 pH는 다중 회귀분석에 의해 제거되었다. 반응표면 분석법(RSM)을 이용한 결과 protein을 회수하기 위한 최적 조건으로는 protein 농도가 38.2 mg/ml, 40%의 ethanol 농도, 침전 온도는 $-8^{\circ}C$였다. 이러한 최적 조건에 의한 회수율의 실험치는 68.97%로 예측치인 77.28%에 근접한 결과였다. 또한 유의 수준을 검정하는 자유도와 F-value도 양호한 값(p<0.001)을 나타내어 종속변수와 독립변수와의 상관관계가 뛰어남을 알 수 있으며 따라서 다중 회귀분석에 얻어진 모델식의 각 변수들 사이에는 유의성이 높음을 알 수 있었다.

  • PDF

Profiling of Recovery Efficiencies for Three Standard Protocols (FDA-BAM, ISO-11290, and Modified USDA) on Temperature-Injured Listeria monocytogenes

  • Lee, Hai Yen;Chai, Lay Ching;Pui, Chai Fung;Wong, Woan Chwen;Mustafa, Shuhaimi;Cheah, Yoke Kqueen;Issa, Zuraini Mat;Nishibuchi, Mitsuaki;Radu, Son
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권9호
    • /
    • pp.954-959
    • /
    • 2011
  • There have been a number of studies conducted in order to compare the efficiencies of recovery rates, utilizing different protocols, for the isolation of L. monocytogenes. However, the severity of multiple cell injury has not been included in these studies. In the current study, L. monocytogenes ATCC 19112 was injured by exposure to extreme temperatures ($60^{\circ}C$ and $-20^{\circ}C$) for a one-step injury, and for a two-step injury the cells were transferred directly from a heat treatment to frozen state to induce a severe cell injury (up to 100% injury). The injured cells were then subjected to the US Food and Drug Administration (FDA), the ISO-11290, and the modified United States Department of Agriculture (mUSDA) protocols, and plated on TSAyeast (0.6% yeast), PALCAM agar, and CHROMAgar Listeria for 24 h or 48 h. The evaluation of the total recovery of injured cells was also calculated based on the costs involved in the preparation of media for each protocol. Results indicate that the mUSDA method is best able to aid the recovery of heat-injured, freeze-injured, and heat-freeze-injured cells and was shown to be the most cost effective for heat-freeze-injured cells.