• Title/Summary/Keyword: Recovery Heat Exchanger

Search Result 181, Processing Time 0.024 seconds

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facility

  • Park, Byung-Kyu;Kim, Moo-Geun;Kim, Geun-Oh
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.17-26
    • /
    • 2001
  • Simulation was conducted using TRNSYS to evaluate the thermal performance of a facility. This facility has a condensing-type heat exchanger which is able to recover the latent energy for the purpose of reducing the heating energy in winter. The boiler and chiller are selected based on the annual peak loads and controlled to maintain the facility at the set temperature of 14~$17^\circ{C}$. Supplied energy by the boiler and recovered energy by the heat exchanger were calculated as a function of number of pass through heat exchanger, kind of fuel and hot water velocity. Simulation results show that about 20% of the total heating load can be recovered by the heat exchanger and the amount of latent heat is increasing with the number of pass. This means that the efficiency of the waste energy recovery system can be increased by using a condensing-type heat exchanger rather than a traditional sensible heat exchanger.

  • PDF

Experimental Study on Naphthalene Heat Pipe Heat Exchanger for Middle-high Temperature Heat Recovery (중고온 범위 폐열회수용 나프탈렌 히트파이프 열교환기에 대한 실험적 연구)

  • Chung, Won-Bok;Park, Soo-Yong;Hwang, Seon-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.64-69
    • /
    • 2007
  • This study is to develop heat recovery system using high performance heat pipe heat exchanger for Middle-high temperature range industrial exhaust gas. The naphthalene is used as working fluid of heat pipe in this study. Single naphthalene heat pipe could transport over 2,000 watts with $0.05^{\circ}C/W$. The heat pipe heat exchanger consist of 50 naphthalene heat pipes recovered 62 kW when over $400^{\circ}C$ gas exhausted and the maximum recovered heat rate was 173 kW in this study.

  • PDF

The Development and Performance Evaluation of the Air-preheating Heat Exchanger for Ultra-high Temperature Applications (초고온융 공기예열식 열교환기의 개발 및 성능 평가)

  • 박용환
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.78-84
    • /
    • 1999
  • A compact air-preheating type heat exchanger was developed and tested for the ultra-high temperature heat recovery applications. For the direct use of exhaust gases up to $1200^{\circ}C$, the heat exchanger adopted a ceramic core with high strength and low thermal expansion coefficient less than $1{\times}10^{-6}^{\circ}C^{-1}$. The ceramic core was fabricated by special extrusion and bonding techniques. To minimize thermal stresses in the core, spring-loaded sealing mechanism was designed and successfully installed. 1-pass air flow scheme was adopted for the compactness and cost-savings. The pressure test for the ceramic core showed no failure under 35 kPa and less than 3% leak under 7 kPa. Flue gas simulation system was developed to investigate the performance of the heat exchanger. The test results showed normal operations of the heat exchanger up to $1200^{\circ}C$ of exhaust gases and relatively high heat recovery efficiencies of 31~39% depending upon exhaust gas temperatures..

  • PDF

Technology of Waste Heat Recovery Using Heat Pipe Heat Exchanger for Industrial Practice (중고온 히트파이프를 이용한 열회수기술에 관한 연구)

  • Lee Young-Soo;Kim Jong-Ryul;Chang Ki-Chang;Baik Young-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1044-1050
    • /
    • 2004
  • The present study has been conducted to develop a heat pipe heat exchanger for middle-high temperature ranged from 300 to $600^{\circ}C$. Heat transfer rate, overall heat transfer coefficient and temperature effectiveness were investigated using a heat pipe heat exchanger with Dowtherm A as working fluid. Theoretical analysis was also conducted, and the followings were obtained: (1) Heat exchange rate increased as waste gas temperature supplied to evaporator and frontal velocity in condenser increased, (2) Overall heat transfer coefficient increased by $3{\sim}7\%$ as frontal velocity in evaporator and condenser increased, (3) Temperature effectiveness was about $30\%$ in evaporator and was about $40\%$ in condenser, (4) Heat recovery rate was about $38\%$, (5) Pressure drop did not exceed $8\;mmH_{2}O$ under the running condition of $1{\sim}3Nm/s$, (6) Simulation results were corresponded with experimental results.

An Experimental Study on Performance of Paper Heat Exchangers for Exhaust Heat Recovery Ventilation System (폐열회수 환기시스템에 사용된 종이 열교환기의 성능에 관한 실험적 연구)

  • Chung, Min-Ho;Oh, Byung-Kil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.240-246
    • /
    • 2012
  • The supply and use of exhaust heat recovery ventilation system as effective energy saving equipment has been increasing steadily. The exhaust heat recovery ventilation system can be installed at ceiling of balcony or emergency space. However, ventilation system can not be installed at emergency space because where have to remain as empty space by law. Therefore, the proper installation space of ventilation system is needed. In this study, to install heat recovery ventilation system in the light weight wall, thickness of heat exchanger was assembled below 140 mm. One or two paper heat exchangers were installed in the ventilation system. The efficiency of heat recovery was analyzed through performance experiment on case of cooling and heating mode.

Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery (연도가스 열회수용 순환유동층 열교환기의 오염저감특성)

  • 이금배;전용두
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator

  • Han, Hwa-Taik;Kim, Min-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • This study investigates the air leakage and heat transfer characteristics of a commercially available rotary-type air-to-air heat exchanger with a fiber polyester matrix. Crossover leakage between the exhaust and supply air is measured using a tracer gas method for various ventilation rates and rotational speeds of the wheel. A correlation equation for the leakage is obtained by summing up pressure leakage and carryover leakage. The pressure leakage is observed to be a function of ventilation rate only, and the carryover leakage is found to be a linear function of wheel speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiency by taking into account the leakage ratio. The heat recovery efficiency decreases, as the ventilation rate increases. As the wheel speed increases, however, the efficiency increases initially but reaches a constant value for the speeds over 10rpm.

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator (회전식 폐열회수 환기유닛의 공기누설 및 전열특성에 관한 실험적 연구)

  • Han Hwataik;Kim Min-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1197-1203
    • /
    • 2004
  • This study investigates the air leakage and heat transfer characteristics of a rotary-type air-to-air heat exchanger with a fiber polyester matrix. The leakage airflow rate is measured using a tracer gas method for various ventilation rates and rotational speeds of the matrix wheel. A correlation equation for air leakage is obtained by combining the pressure leakage and the carryover leakage. The pressure leakage is observed to be a function of ventilation airflow rate only, and the carryover leakage is found to be a linear function of rotational speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiencies by taking into account the air leakage ratio. As the ventilation rate increases, the heat recovery efficiency decreases. As the rotational speed of the matrix increases, the efficiency increases initially but reaches a constant value for the rotational speeds over 10 rpm.

An Experimental Study on the Possibility of Biogas Reforming using the Waste Heat of a Small-Sized Gas Engine Generator (소형 가스엔진 발전기의 배기가스 폐열을 이용한 바이오가스 개질 가능성에 관한 실험적 연구)

  • Cha, Hyo-Seok;Kim, Tae-Soo;Eom, Tae-Jun;Jung, Choong-Soo;Chun, Kwang-Min;Song, Soon-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.3
    • /
    • pp.236-242
    • /
    • 2012
  • This study has been carried out the experiment for the possibility of biogas reforming using waste heat. The source of this waste heat is the exhaust gas from a small-sized gas engine generator. For recovering the waste heat, Two-stage heat exchanger is manufactured. The two-stage heat exchanger is composed of a heat exchanger for the exhaust gas and a heat exchanger for the water. This two-stage heat exchanger is used for reforming the biogas by means of on-site hydrogen production at the small-sized gas engine generator. The two-stage heat exchanger is coupled with the biogas reformer which is a kind of catalytic reformer. To confirm a heat recovery efficiency of the two-stage heat exchanger, temperature differences of inlet and outlet locations are measured. Also, the variations of syngas concentrations with various biogas flow rates are investigated. As a result using manufactured two-stage heat exchanger, the biogas can be reformed from waste heat recovery. This experiment suggests that the exhaust gas heat exchanger is available for reforming the biogas.

Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery (저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성)

  • 이욱현;임용빈;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF