• Title/Summary/Keyword: Record base

Search Result 250, Processing Time 0.029 seconds

JAW RELATION WITH PERMANENT RECORD BASES IN THE EDENTULOUS PATIENTS (총의치 환자에 있어 Permanent record base를 이용한 악간관계 기록)

  • Heo, Yun-Seok;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.231-239
    • /
    • 1995
  • When the complete denture is made, the record base for jaw relation is divided into temporary record base and permanent record base. However, The temporary record base include some disadvantages such as, the lackness of intimate contact between model and base, the lackness of retention during the jaw relation registration, When we obtained jaw relation the permanent record bases made from heat curing resin were utilized. We could get several advantages as follows : 1. The permanent record base provided intimate contact between the model and record base. 2. In fabricating occlusal rim on record base, the dimensional change of record base was little because the permanent record base was lesser influenced to thermal change of occlusal rim than the temporary record base. 3. At the stage of jaw relation, the retention of final denture could be early checked. 4. It could be able to get more accurate registration of jaw relation because all procedure were done on the same base during the jaw relation, artificial teeth arrangement, try-in, and final denture construction. 5. Although there was an inconvenience due to double curing procedure, the shrinkage rate in resin polimerization was relatively reduced so that more dimensional stability could be taken.

  • PDF

A STUDY ON THE FITNESS OF THE RESIN RECORD BASE (레진기초상의 적합도에 관한 연구)

  • Ji, Jae-Seon;Han, Sang-Hoon;Oh, Sang-Chun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.611-619
    • /
    • 1996
  • The purpose of this study was to evaluate the fitness of 4 kinds of resin record base materials. The record base materials used on the edentulous cast in this study were Triad VLC resin (Dentsply International Inc., U.S.A.), custom tray resin (Kerr Ltd., U.S.A.), heat-cure resin (Dentimex Co., Holland), and self-cure resin (Dentimex Co., Holland). The gap width between record base and cast were measured in the ridge crest and midpalatal area with microhardness tester. The results obtained were as follows : 1. Among the 4 kinds of record base, heat-cure Vertex fitted best on the cast. Triad and Fomatray fitted better than self-cure Vertex. Self-cure Vertex had the poorest fit. 2. The quality of the fit of the record base varied at different locations on the cast. The record base fit better in the ridge crest than midpalatal area. 3. In the midpalatal area, there's no significant difference in the fit of Fomatray, Triad and heat-cure Vertex. They all fit better than self-cure Vertex. 4. In the ridge crest, heat-cure Vertex fit better than any other record base.

  • PDF

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF

Development of a Knowledge-Based Job Shop Scheduler Applying the Attribute-Oriented Induction Method and Simulation (속성지향추론법과 시뮬레이션을 이용한 지식기반형 Job Shop 스케쥴러의 개발)

  • 한성식;신현표
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.48
    • /
    • pp.213-222
    • /
    • 1998
  • The objective of this study is to develop a knowledge-based scheduler applying simulation and knowledge base. This study utilizes a machine induction to build knowledge base which enables knowledge acquisition without domain expert. In this study, the best job dispatching rule for each order is selected according to the specifications of the order information. And these results are built to the fact base and knowledge base using the attribute-oriented induction method and simulation. When a new order enters in the developed system, the scheduler retrieves the knowledge base in order to find a matching record. If there is a matching record, the scheduling will be carried out by using the job dispatching rule saved in the knowledge base. Otherwise the best rule will be added to the knowledge base as a new record after scheduling to all the rules. When all these above steps finished the system will furnish a learning function.

  • PDF

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

  • Huh, Jung-Bo;Kang, Min-Goo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.102-105
    • /
    • 2010
  • PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed ($\alpha$ = 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

Design and Implementation of Electronic Medical Record System Based on HL7-CDA for the Exchange of Clinical Information (임상 정보교환을 위한 HL7-CDA 기반의 전자의무기록 시스템의 설계 및 구현)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.5B
    • /
    • pp.379-385
    • /
    • 2008
  • For the sharing and exchange of information between medical clinics, the clinical document has to be built on a standardized protocol such as a HL7-CDA. But it is difficult to exchange information between medical clinics because clinical document such as electronic medical record that include text and image, have different structure of document and type of expression. In this paper, we propose the electronic medical record system based on HL7-CDA that can share and exchange clinical information between medical institute. For this purpose, we have to design the schema of the clinical document architecture after we select the essential items of medical record and define templates. The proposed system can minimize integrating process and save parsing time when clinical information exchange and refer, by converting electronic medical record to base64 encoding scheme and integrate it in a XML document.

A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report

  • Choi, Hyunsuk;Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.4
    • /
    • pp.341-343
    • /
    • 2022
  • To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening of the impression coping. Here, we report a useful and novel method for interocclusal records using the healing abutments in implant overdentures. Our case demonstrates that this method is easier and simpler and prevents gingival collapse.

Analysis of the Relationship between a Batter's Performance and Discomfort Index using Big Data: focusing on the Number of Pitches and On Base Percentage (빅데이터를 활용한 타자의 출루 관련 경기력과 불쾌지수의 관계 분석 : 투구 수 유도와 출루율을 중심으로)

  • Kim, Semin;You, Kangsoo
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.61-66
    • /
    • 2020
  • Recently, attempts have been made to use data to operate games, seasons, and teams in professional baseball. Therefore, in this study, we collected baseball game records and analyzed the relationship between on-base rate and pitching count induction, and this was defined as the third record for non-game factors such as discomfort index, which includes the weather application data. When the discomfort index was over 75, the pitcher's induction of pitching was high, and when the discomfort index was less than 69.9, the on-base rate was high, but when the discomfort index was 70 or more and less than 75, the batter's on-base performance was the lowest. Through the results of the study, it could be inferred that the discomfort index, the batter's on-base rate, and the number of induction pitches are related, and that it is highly likely to be related to the pitcher's performance. Through this study, we could see the possibility of defining a cumulative/ratio record defined as the primary record and a saver metric defined as the secondary record, and a third, tertiary record linking data outside the game.

A Predictive Preventive Maintenance Data Base System Design for Safety (안전성 확보를 위한 예측.예방설비보전 데이터베이스 시스템 설계)

  • Yang, Sung-Hwan;Park, Peom
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.123-128
    • /
    • 1997
  • A data base design framework for predictive a preventive-maintenance system is presented in this paper in order to effectively control machines and reduce accident rates in the workplace. The data base is designed to meet general management requirements to evaluate different maintenance strategies. There are seven data files: the equipment list maintenace pesonnel, maintenance history, maintenance specification, spare part, maintenance equipment, and maintenance schedules. Each data base file has several record based upon data acquisition.

  • PDF