• 제목/요약/키워드: Recommended system

검색결과 2,647건 처리시간 0.026초

컨테이너 터미널 장비의 RAM 향상을 위한 관리 시스템 (Management System for Improving RAM of Equipment in Container Terminals)

  • 윤원영;김귀래;하영주;손범신;김혜정
    • 산업공학
    • /
    • 제19권3호
    • /
    • pp.245-254
    • /
    • 2006
  • Equipments in container terminal have a lot of parts, and an equipment breakdown affects the productivity of terminal. In this paper, we develop a maintenance management system for improving reliability, availability and maintainability of equipments in container terminals. The developed system consists of five modules : equipment structure module, equipment operation management module, maintenance control module, spare part control module and data analysis module. The system supports reliability engineers to manage and improve RAM of equipments in container terminals. For example, FMEA, failure state analysis and life distribution parameters estimation are easily or automatically done by the system. This system also provides optimal preventive maintenance intervals by simulation and optimal yearly PM schedules for equipments in container terminal are recommended.

100 kW급 용융탄산염 연료전지 시스템 개발 II(스택 및 시스템 설계) (System Development of a 100 kW Molten Carbonate Fuel Cell II (Design of Stack and System))

  • 임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1322-1324
    • /
    • 2002
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately 170 cells are required to generate 100 kW at a current density of 125 mA/$cm^2$ with 6000 $cm^2$ cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at 125 mA/$cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. Also system efficiency was calculated at various type of system and operation conditions.

  • PDF

The Strategy for Intelligent Integrated Instrumentation and Control System Development

  • Kwon, Kee-Choon;Ham, Chang-Shik
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.153-158
    • /
    • 1995
  • All of the nuclear power plants in Korea we operating with analog instrumentation and control (I&C) equipment which are increasingly faced with frequent troubles, obsolescence and high maintenance expenses. Electrical and computer technology has improved rapidly in recent years and has been applied to other industries. So it is strongly recommended we adopt modern digital and computer technology to improve plant safety and availability. The advanced I&C system, namely, Integrated Intelligent Instrumentation and Control System (I$^3$CS) will be developed for beyond the next generation nuclear power plant. I$^3$CS consists of three major parts, the advanced compact workstation, distributed digital control and protection system including Automatic Start-up/shutdown Intelligent Control System (ASICS) and the computer-based alarm processing and operator support system, namely, Diagnosis, Response, and operator Aid Management System (DREAMS).

  • PDF

100 kW급 용융탄산염 연료전지 시스템 개발 I (시스템 및 스택 설계) (System Development of a 100 kW Molten Carbonate Fuel Cell I (Design concept of Stack and System))

  • 임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1300-1302
    • /
    • 2001
  • For developing a 100 kW MCFC power generation system. Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately 170 cells are required to generate 100 kW at a current density of $125mA/cm^2$ with $6000cm^2$ cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. Also system efficiency was calculated at various type of system and operation conditions.

  • PDF

대공간 연성 구조시스템의 종류와 발달과정 (The Type and Development for Structure System with Non-rigid Member)

  • 이주나;박선우;박찬수
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.148-157
    • /
    • 2004
  • The structure systems with non-rigid member were classified by the composition type of line and surface members. As a result of the classification, there are 1-way cable structure, cable net and radial cable net structure in the line member system. And there are pneumatic structure and suspension membrane structure in surface member system. In addition, when the line and surface members are composed together, there is the hybrid membrane system which are divided into hanging type and supported type. In this paper, the Korean terms of structure systems with non-rigid member are recommended through this classification. In each the structure systems with non-rigid member, the examples were also investigated considering their historical developments. It present that the light weight structure system and the openness of space have pursued with the developments. So largely, cable net structure with membrane, membrane structure and hybrid structure have used in these days.

  • PDF

프로펠러 가공 전용 CAD/CAM 시스템 개발 (Development of a CAD/CAM System for Marine Propeller)

  • 전용태;윤재웅;박세형
    • 한국정밀공학회지
    • /
    • 제17권9호
    • /
    • pp.53-61
    • /
    • 2000
  • The manufacture of a marine propeller typically requires long lead time to generate 5-axis tool path. Hence it may take several weeks to manufacture a satisfactory propeller with a general purpose CAD/CAM system. In this research a dedicated 5-axis CAD/CAM system for machining marine propellers has been developed, The system employs various methods to enhance the productivity : interference-free tool path generation employing check vectors and optimum cutter size determinants. In addition an iterative NURBS modeling technique is used to improve the accuracy of the modeled surface and effective cutting conditions are determined and recommended empirically to increase the productivity. The proposed CAD/CAM system has been implemented with C++ and OpenGL graphic library on the Windows system. The system validation and sample results are also given and discussed.

  • PDF

내국신용장(Local L/C) 개설 및 결제에서의 에스크로 시스템 적용에 관한 고찰 (A Review on the Adaptation of Escrow System in Local L/C Opening and Payment)

  • 이제홍
    • 통상정보연구
    • /
    • 제7권3호
    • /
    • pp.97-111
    • /
    • 2005
  • This paper object is application of electronic Customers Relationship Management(e-CRM) for buyer This paper focuses on the possibility of the adaption of Escrow system in Local L/C opening and payment. The purposes of this study are to obtain efficiency and stability of Local L/C and to provide opportunity to accept trust of the transaction parties. The results of the study show that Escrow system is recommended when Local L/C opened, because Escrow system has the following merits: (1) Open system of internet can be used to Local L/C process. (2) Transaction process of Escrow system is very simple. (3) One stop transaction can be applied to all the process of local L/C.

  • PDF

순동예비력을 고려한 계통의 최적운용방식에 관한 연구 (Study on the optimum system operation by considering the spinning reserve power)

  • 송길영
    • 전기의세계
    • /
    • 제24권5호
    • /
    • pp.97-102
    • /
    • 1975
  • This paper describes the result of a Study for the Optimum Operating method with Spinning reserve in case of outage of large generator unit to improve the system stability and prevent the system frequency drop. This is usually done by governor free operation, so we focused our attention to the operating Char acteristics of spinning reserve. Nexy, a study was made to mesure the upper limit of Spinning reserve and when this upper limit cannot match the required power, a relationship between the amount of spinning reserve and that of the load shedding requirement was searched with regard to several system operating conditions to use it in our future system operation. By this study, the optimum system operating method was recommended for reliable operation of power system.

  • PDF

대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량 (A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate)

  • 박외철
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

데이터센터 냉방시스템 고효율화를 위한 국내 수열에너지 보급 제도 개선에 관한 연구 (A Study on the Improvement of the Water Source Energy Distribution Regulation for High Efficient Data Center Cooling System in Korea)

  • 조용;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, the current regulation of the water source energy, one of the renewable energy, was analyzed, and the improvement plan for the high efficient data center cooling system was suggested. In the improvement plan, the design and construction guidelines of the water source energy system permit to adopt the cooling and heating system with or without heat pump. In addition, it should also include the system operated in the cooling mode only all year-round. The domestic test standards to consider the water source operating conditions should be developed. Especially, it is highly recommended that the test standards to include the system with forced cooling and free cooling modes related with the enhanced data center cooling system adopting the water source energy.