재폐로방식이 전력용 변압기에 미치는 영향 평가 (Evaluation of Damage from Reclosing Scheme for Power Transfromer)

  • 오정환;윤상윤;임성정;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.177-183
    • /
    • 1999
  • This paper presents how to evaluate the transformer damage caused by reclosing scheme at the distribution substation. We describe a quantitative relationship between the reclosing scheme and the number of fault current flowing through transformer wsing the probability of a reclosing success/failure. The transformer damage from reclosing scheme is presented using a weight function and a damage function. A weight function is associated with the number of reclosing attempts and the reclosing deadtime to consider cumulative stress caused by reclosing scheme. A damage function is associated with a transformer impact ratio and a transformer functional life. In the case study, the transformer damage is simulated for the probability of a reclosing success. And the evaluation of transformer damage using KEPCO's operation data is performed.

  • PDF

사고 패턴 분류에 기초한 배전계통의 적응 재폐로방식 (An Adaptive Reclosing Scheme Based on the Classification of Fault Patterns in Power distribution System)

  • 오정환;김재철;윤상윤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.112-119
    • /
    • 2001
  • This paper proposes an adaptive reclosing scheme which is based on the classification of fault patterns. In case that the first reclosing is unsuccessful in distribution system employing with two-shot reclosing scheme, the proposed method can determine whether the second reclosing will be attempted of not. If the first reclosing is unsuccessful two fault currents can be measured before the second reclosing is attempted, where these two fault currents are utilized for an adaptive reclosing scheme. Total harmonic distortion and RMS are used for extracting the characteristics of two fault currents. And the pattern of two fault currents is respectively classified using a mountain clustering method a minimum-distance classifier. Mountain clustering method searches the cluster centers using the acquired past data. And minimum-distance classifier is used for classifying the measured two currents into one of the searched centers respectively. If two currents have the different pattern it is interpreted as temporary fault. But in case of the same pattern, the occurred fault is interpreted as permanent. The proposed method was tested for the fault data which had been measured in KEPCO's distribution system, and the test results can demonstrate the effectiveness of the adaptive reclosing scheme.

  • PDF

배전시스템센서의 순간전압강하 분석 (Analysis of Voltage Sag on Power Distribution System)

  • 오정환;임성정;윤상윤;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.954-957
    • /
    • 1997
  • In this paper, we analyze the voltage sag caused by reclosing on electric power distribution system. When a fault is on the electric system, a reclosing operation brings a voltage sag on the feeders which is supplied with a common substation transformer. By analyzing the fault wave-form measured in the field, it is showed that a voltage sag is in proportion to a fault current. Also, we propose an adaptive reclosing scheme. This scheme changes the number of reclosing as a function of the magnitude of a fault voltage and the fault type. As the proposed scheme is compared with conventional scheme in the side of voltage sag and permanent fault, it is verified that the proposed scheme is more effective than conventional scheme.

  • PDF

배전시스템에서 적응재폐로방식의 적용에 관한 연구 (Applications of an Adaptive Reclosing in Power Distribution Systems)

  • 임성정;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.955-957
    • /
    • 1998
  • This paper presents an adaptive reclosing scheme to improve the reliability in power distribution systems. For an originated faults, this scheme can determine the number of reclosing attempts, so that minimizes the affect of electric facility and customers' load. To verify the effectiveness of the proposed scheme. numerical simulation which calculates a various indices to consider the reliability and the effect of electric facility, is carried out with actual field data. Results show that the proposed scheme can be applicable to field operation.

  • PDF

송전계통 과도 안정도 향상을 위한 최적 순차 재폐로에 관한 연구 (A Study on Optimal Sequential Reclosing to Improve Transient Stability in Transmission System)

  • 권기현;오윤식;박지경;조규정;손승현;김철환
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1354-1360
    • /
    • 2013
  • In transmission system, reclosing scheme is very useful method to improve continuity of power supply and reliability of system. Especially, high speed reclosing which is used generally in transmission systems has a benefit improving transient stability. However, the reclosing can jeopardize the stability under the condition having high difference of voltage phase angle between both ends. Thus, this paper proposes optimal sequential reclosing scheme to improve transient stability due to reclosing operation. The optimal sequential reclosing is that each phase is closed sequentially considering transient energy. In this paper, 345kV and 154kV transmission system is modeled using EMTP (ElectroMagnetic Transient Program) to verify the performance and effectiveness of optimal sequential reclosing on transient stability. Also, Integral Square Error(ISE) method is used to assess the transient stability.

Development of a Reclosing Scheme for Reduction of Turbine Generator Shaft Torsional Torques: A Decision Method to Achieve Optimal Reactor Capacity

  • Oh, Yun-Sik;Seo, Hun-Chul;Yang, Jeong-Jae;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1145-1153
    • /
    • 2014
  • It is well known that line switching operations like reclosing are able to cause transient power oscillations which can stress or damage turbine generators. This paper presents a reclosing scheme to reduce the shaft torsional torques of turbine generators by inserting an additional reactor. A novel method to determine optimal reactor capacity to minimize the torsional torque generated in a turbine generator is also proposed. In this paper, the turbine generator shaft is represented by a multi-mass model to measure torsional torques generated in the shaft between the turbine and the generator. Transmission systems based on actual data from Korea are modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. The simulation results clearly show the effectiveness of the proposed scheme and torsional torque can be minimized by applying the proposed scheme.

최적 재폐로방식 선정에 관한 연구 (A Study on the Determination of Optimal Auto-reclosing)

  • 김일동;한경남;임성정;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.861-863
    • /
    • 1997
  • This paper presents a reliability and power quality taken account of the reclosing scheme on the power distribution system. To determine the optimal reclosing scheme, the simple radial distribution system is modelled, and analyzes quantitatively the effect of customer's load to the number of reclosing. The result of the analysis shows that the determined reclosing scheme can satisfy both the reliability and the power quality in the power distribution system.

  • PDF

전력품질을 고려한 배전시스템에서의 개선된 재폐로방식에 관한 연구 (Advanced Reclosing Schemes in Power Distribution Systems Considering Power Quality)

  • 임성정;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권1호
    • /
    • pp.1-6
    • /
    • 2002
  • This paper proposes an advanced reclosing scheme to improve power quality in power distribution systems. When a fault occurs in distribution system, the proposed schema determines the number of reclosing shots and its intervals according to the magnitude of fault current. Thus, an advanced reclosing scheme takes account of the power quality problem in customer\`s and the damage in electric facilities. To verify the effectiveness of the proposed scheme, a numerical simulation that calculates various indices to consider the reliability and the other effects on electric facility, in carried out with actual field data.

전력설비 피해 감소를 위한 지능형 재폐로방식에 관한 연구 (Intelligent Reclosing Scheme to reduce a Damage of Power Equipments)

  • 임성정;김재철
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.112-117
    • /
    • 2001
  • 본 논문은 전력설비 피해 감소를 위한 배전시스템의 지능형 재폐로방식을 제안하였다. 재폐로 시도횟수를 늘릴수록 공급신뢰도는 향상될 수 있지만, 전력설비에는 사고전류에 의한 충격이 누적된다. 제안된 방식은 사고전류의 크기에 따라 재폐로 시도횟수와 무전압시간을 결정하여 배전시스템 공급신뢰도를 유지하면서 전력설비의 피해를 감소시킬 수 있다. 사례연구에서는 현장 운전 데이터를 사용하여 제안된 지능형 재폐로방식에 대한 효율성을 입증하였다.

  • PDF

765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책 (The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection)

  • 안상필;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.