• Title/Summary/Keyword: Recirculation region

Search Result 226, Processing Time 0.024 seconds

Numerical Simulation of Spray Behavior and Its Interaction with Air Flow in Oil Burner (오일 버너에 있어서 분무거동과 공기유동의 상호작용에 관한 수치해석)

  • 나가지마
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.320-330
    • /
    • 1999
  • A numerical study was performed to investigate spray behavior and its interaction with air flow in a flame holding region of an oil burner(0.1MW) using the KIVA3 code. The numerical results in shape of the recirculating flow and size of the recirculation zone under different conditions were compared to those experimental results. The numerical results in fuel droplet trajectory show that a droplet under 30${\mu}m$ can follow the air flow but a droplet over 50${\mu}m$ penetrates the recirculation zone due to large momentum and a droplet of 30-50${\mu}m$ can follow the recirculating flow or pene-trates the recirculation zone.

  • PDF

A Study for the Performance Improvement of the Main Lubrication Oil Pump (선박용 주 윤활유 펌프의 성능 개선에 대한 연구)

  • Kim, Jin-Young;Chung, Kyung-Nam;Kim, Ju-Baek;Yang, Han-Jo;Lim, Shin-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.660-664
    • /
    • 2004
  • The flow fields of a lubrication oil pump has been simulated by using CFD in order to improve performance of the pump. The grid for the one flow passage is applied for estimating pump performance. The calculation result shows that there are unfavorable flow characteristics of flow recirculation in the casing part by the guide vane. Thus, the guide vane is modified to reduce the recirculation region. Performance test shows that the modified model pump efficiency is increased by $6\%$ at the rated point compared to that of the original model.

  • PDF

Combustion Characteristics of Flameless Combustion by Reactants Injection Conditions (반응물 분사조건에 따른 무화염 연소특성 연구)

  • Hong, Seong Weon;Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.8-16
    • /
    • 2013
  • The flameless combustion has been considered as one of the promising combustion technology for high thermal efficiency, reducing NOx and CO emissions. In this paper, the effect of air and fuel injection condition on formation of flameless combustion was analyzed using three dimensional numerical simulation. The results show that the high temperature region and the average temperature was decreased due to increase of recirculation ratio when air velocity is increased. The average temperature was also affected by entrainment length. Generally mixing effect was enhanced at low entrainment length and dilution was dominated at high entrainment length. This entrainment length was greatly affected by air and fuel injection velocity and distance between air and fuel. It is also found that the recirculation ratio and dilution effect were generally increased by entrainment length and the recirculation ratio, mixing and dilution effect are the significant factor for design of flameless combustion system.

The Effect of Fire Plume on the Characteristics of Air Flow and $CO_2$Extinguishant Transfer (화재화염이 유동 및 $CO_2$소화제 전달특성에 미치는 영향)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.33-43
    • /
    • 2002
  • To analyze the effect of fire plume on the characteristics of air flow and $CO_2$, extinguishant transfer when extinguishant is injected into a closed space similar to a marine engine room with fire plume, a numerical simulation on a space was performed. Flow fields and $CO_2$, concentration fields are calculated according with the variation of the location of nozzles. In all cases excepting the case of all nozzles located in the right side of ceiling, an counterclockwise & clockwise recirculation flow was found in the region of the right and left side of the nozzle on the second floor and such a recirculation flow greatly affected mass transfer and the diffusion process of $CO_2$, extinguishant. In the region of the first floor with fire plume, the diffusion process of $CO_2$, extinguishant was in agreement with the extension process of recirculation flow. It is considered that the result of this study can be useful to designing the arrangement of nozzles for the $CO_2$ fire fighting equipments in a marine engine room.

Flow comparison between Stenosed Coronary and Abdominal Arteries (협착된 관상동맥과 복부 대동맥의 유동 특성 비교)

  • Kim, M.C.;Lee, C.S.;Kim, C.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.585-590
    • /
    • 2001
  • The hemodynamic characteristics were compared using commercial CFD code for the stenosed coronary and abdominal arteries. Numerical calculations were carried out in the axisymmetric arteries over the stenotic diameter ratios ranging from 0.25 to 0.875 (6 cases) employing the typical physiological flow conditions. In case of the coronary artery, there was only one recirculation zone observed distal to the stenosis throat during the major portion of the period. However, in case of the abdominal aorta, there were complex recirculation regions found proximal and distal to stenosis throat. For both models, the wall shear stresses(WSS) increased sharply in the converging stenosis, reaching a peak just upstream of the throat, and became negative or low values in the post-stenotic recirculation region. As the results, the oscillatory shear index(OSI) was abruptly increased at the stenosis throat. For the coronary stenosis model, the second peak in the OSI was observed distal to the stenosis. The distance between the first peak and the second peak was increased as the degree of the stenosis was raised. On the orther hand, the abdominal stenosis model showed a complex oscillatory behavior in the OSI index and did not showed such a strong second peak. As the degree of stenosis was increased, recirculation regions of the both arteries were extended much longer and flow pattern became more complex.

  • PDF

Buoyancy-Affected Separated Laminar Flow over a Vertically Located, Two-Dimensional Backward-Facing Step (수직으로 놓인 후향계단위를 흐르는 유체유동에 미치는 부력의 영향에 관한 연구)

  • 백병준;박복춘;김진택
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1253-1261
    • /
    • 1993
  • Numerical analysis and measurements of the velocity and temperature distributions in buoyancy assisting laminar mixed convection flow over a vertically located, two-dimensional backward-facing step are reported. Laser-Doppler Velocimeter and Constant Temperature Anemometer operated in constant current were used to measure simultaneously the velocity and temperature distributions in the recirculation region downstream of the step. The reattachment length was measured by using flow visualization technique for different inlet velocities, wall temperatures and step heights. While the reattachment length $X_r$ increases as the inlet velocity or step height increase, it decreases as the buoyancy force increases, causing the size of the recirculation region to decrease. For the experimental range of $Gr_s$/$Re_{s}^{2}$$\times$$10^3$<17, a correlation equation for the reattachment length can be given by $X_{r}=1.05(2.13+0.021 Re_{s})exp$ $(-33.7_s^{-0.186}/Gr_{s}/Re_{s}^2).$ The Nusselt number is found to increase and the location of its maximum value moves closer to the step as the buoyancy force increases. The location of the maximum Nusselt number occurs downstream of the reattachment point, and distance between the reattachment point and the location of the maximum Nusselt mumber increases as the buoyancy force increases. Computational prediction agrees favorably well with measured results.

Analysis on the Heat Exchange Efficiency of Kraft Recovery Boiler by Nose Arch Structure Using CFD (CFD를 활용한 크래프트 회수보일러 내부 노즈 아치 구조에 따른 열교환 효율 분석)

  • Jang, Yongho;Park, Hyundo;Lim, Kyung pil;Park, Hansin;Kim, Junghwan;Cho, Hyungtae
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.149-156
    • /
    • 2021
  • A kraft recovery boiler produces steam for power generation by the combustion of black liquor from the kraft pulping process. Since saturated steam became superheated in a superheater above the furnace, it is important to increase the heat exchange efficiency for the superheated steam production and power generation. A nose arch at the bottom of the superheater is important for blocking radiation from the furnace which causes corrosion of the superheater. But the nose arch is the main reason for creating a recirculation region and then decreasing the heat exchange efficiency by holding cold flue gas after the heat transfer to saturated steam. In this study, the size of recirculation region and the temperature of flue gas at the outlet were analyzed by the nose arch structure using computational fluid dynamics (CFD). As a result, when the nose arch angle changed from 106.5° (case 1) to 150° (case4), the recirculation region of flue gas decreased and the heat exchange efficiency between the flue gas and the steam increased by 10.3%.

Experimental Investigation of Two Parallel Plane Jets (두 개의 평행한 평면 제트의 실험적 연구)

  • Kim Dong-Keon;Yoon Soon-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.214-223
    • /
    • 2005
  • The characteristics of flow on two parallel plane jets was experimentally investigated. The two nozzles each with an aspect ratio of 20 were separated by 6 nozzle widths. Reynolds number based on nozzle width was set to 5,000 by nozzle exit velocity. The particle image velocimetry and pressure transducer were employed to measure turbulent velocity components and mean static pressure, respectively. In case of unventilated parallel plane jets, it was shown that a recirculation zone with sub-atmospheric static pressure was bounded by the inner shear layers of the individual jets and the nozzles plated. There was no recirculation zone in the ventilated parallel plane jets. It was found that the spanwise turbulent intensities of unventilated jets were higher than those of ventilated jets because of the interaction of jets, and the streamwise turbulent intensities of ventilated jets were higher than those of unventilated jets because of the effect of entrainment.

Junction Flow Analyses by Twp-Dimensional Numerical Model (2차원 수치모형에 의한 합류흐름 해석)

  • Yoon, Tae-Hoon;Jung, Eui-Taek;Park, Jong-Suk
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.5
    • /
    • pp.529-538
    • /
    • 1998
  • The flow configurations at open channel junctions are analyzed by 2-D depth averaged mathematical model. The governing factors of the flow at the junction are found to be discharge ratio between tributary flow and the post confluence combined flow, and confluence angle. Analyzed by these two factors are flow patterns and flow depth variation at the confluence, discharge ratio above which the flow upstresm from the junction is affected by the tributary flow and the geometries of a recirculation region. Further, the flow contraction in the downstream region and the deflection of the tributary flow in the main channel were investigated. The numerical results are compared with the existing experimental data fairly well.

  • PDF

A COMPUTATIONAL ANALYSIS FOR OUTLET SHAPE DESIGN TO SUPPRESS FLOW RECIRCULATION IN A ROTATING-DISK CVD REACTOR (회전원판형 CVD 장치의 유동 재순환을 억제하는 출구부 형상 설계를 위한 전산해석)

  • Park, J.J.;Kim, K.;Kwak, H.S.
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.74-81
    • /
    • 2013
  • A numerical design analysis is conducted to search for an optimal shape of outlet in a rotating-disk CVD reactor. The goal is to suppress flow recirculation that has been found in a reactor having a sudden expansion of flow passage outside of the rotating disk. In order to streamline gas flow, the sidewall at which the flow in the Ekman layer is impinged, is tilted. The axisymmetric laminar flow and heat transfer in the reactor are simulated using the incompressible ideal gas model. For the conventional vertical sidewall, the flow recirculation forming in the corner region could be expanded into the interior to distort the upstream flow. The numerical results show that this unfavorable phenomenon inducing back flow could be dramatically suppressed by tilting the sidewall at a certain range of angle. The assessment of deviation in deposition rate based on the characteristic isotherm illustrates that the sidewall tilting may expand the domain of stable plug-like flow regime toward higher pressure. A physical interpretation is attempted to explain the mechanism to suppress flow recirculation.