• Title/Summary/Keyword: Recirculating water system

Search Result 98, Processing Time 0.027 seconds

Numerical Analysis of A Vortex Cyclone in A Recirculating Aquaculture System (순환여과 양식장에서 와류형 분리기에 대한 수치적 검토)

  • Jeong, S.K.;Kim, E.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2005
  • This study investigated the performance of a vortex hydrocyclone for solid removal in a recirculating aquaculture system. In a fish-breeding industry, effluent water is mainly disposed by gravity sedimentation. Thus, a large settling tank and a lot of water are needed to purify effluent water. However, this typical method does not show consistent efficiency. In case of low efficiency, discharged water contains a lot of feeding sediments. This causes environmental problems. Instead of this typical method a hydrocylone is tested to discharge water which contains a lot of feeding sediments. In this paper, a hydrocyclone with low velocity and pressure drop in a recirculating aquaculture system is investigated.

  • PDF

Removal of Suspended Solids Using a Flexible Fiber Filter in a Recirculating Aquaculture System (유연성 섬유사 여과기를 이용한 순환여과식 양식장의 부유고형물 제거)

  • Choi, Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2007
  • The suitability of a flexible fiber filter for removing suspended solid (SS) in a recirculating aquaculture system was evaluated. This study focused on variation in the performance with a change in filtering time, influent water quality, and filtering mode duration. The particle distribution diagram of the filter effluent showed that the number of particles bigger than $5-8{\mu}m$ decreased dramatically, and the removal efficiency exceeded 80%. Although the removal efficiencies of SS and chemical oxygen demand (COD) were dependent on the quality of the influent, the SS and COD concentrations of the effluent were not affected by the influent concentrations. This was despite the deterioration if water quality after feeding in the rearing tank. The performance of the filter was not affected by the filtering mode duration, feeding conditions, or filtering time. The SS concentration and turbidity of the recirculating-type rearing tank were 30% and 50% lower, respectively, than of the a non-recirculating-type rearing tank under the same operating conditions. The flexible fiber filter was applicable to a recirculating aquaculture system that uses plenty of seawater, based on its low filtering resistance $(2kg_f/cm^2)$, high flux $(330m^3/m^2/hr)$, and high fine particle removal efficiency (80%, $5-8{\mu}m$).

Design and Performance of a Laboratory Scale Closed Seawater Recirculating System for Korean Rockfish Sebastes schlegeli Culture Part 1. Design of the Closed Seawater Recirculating System

  • Lei Peng;Oh, Sung-Yong;Jo, Jae-Yoon
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.125-125
    • /
    • 2003
  • Recirculating aquaculture systems consist of different treatment compartments that maintain water quality within the ranges of commonly recommended for fish culture. This paper presents the common considerations in designing different treatment compartments as well as the engineering criteria in designing closed recirculating aquaculture system including a circular tank for fish culture, a sedimentation basin and a foam fractionator for solids removal, two styrofoam bead filters for TAN removal, a sand filter for nitrate removal, and aerators. The main purpose is to outline a common procedure in designing of closed recirculating aquaculture system for marine fish culture.

  • PDF

Inorganic Nutrient Removal Efficiency of Aquatic Plants from Recirculating Aquaculture System (수생식물을 이용한 담수 순환여과식 양식용수내의 무기영양염 처리 효율)

  • 마진석;오승용;조재윤
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.171-178
    • /
    • 2003
  • Inorganic nutrients such as nitrogen and phosphate compounds accumulate in recirculating aquaculture systems. These nutrients must be removed from the system before they affect pH and fish health. For this purpose, aquatic plants are a simple and inexpensive method of removal. There are four commonly used aquatic plants: Eichhornia crassipes (water hyacinth), Pistia stratiotes (water lettuce), Hygrophila angustifolia, and Hydrocotyle leucocephala in freshwater recirculating aquaculture systems in Korea, but their efficiencies are not known. Therefore, removal efficiencies of inorganic nutrients from a freshwater recirculating aquaculture water with four commonly used aquatic plants were tested. Removing efficiencies of TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N of the plants in 210 L aquaria for 48-hour period were tested. The removing efficiencies of TAN, N $O_3$$^{[-10]}$ -N, and P $O_4$$^{3-}$-P of the two most effective plants, water hyacinth and water lettuce, were also tested in 690 L (surface area of 1.55 $m^2$) tanks under 2 different initial stocking densities, 4 kg and 6 kg, for 22 days. Proximate analysis major nutrients and N and P contents of the all plants were analyzed for calculating net removal weight of N and P by the plants. Water lettuce was the most effective for removing TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N from the water for 48-hour period tested followed by water hyacinth and Hygrophila angustifolia. Water lettuce reduced TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N concentration from 2.3 mg/L, 0.197 mg/L, and 21.4 mg/L to 0.4 mg/L, 0.024 mg/L and 17.4 mg/L, respectively while water hyacinth reduced them down to 0.6 mg/L, 0.029 mg/L and 17.9 mg/L, respectively. The concentrations of TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N in Hydrocotyle leucocephala group were rather increased up to 3.7 mg/L, 5.7 mg/L and 48.2 mg/L, respectively. This is because the creeping stem of Hydrocotyle leucocephala had to be cut to meet stocking weight resulting in decaying of the stem in the aquaria during experiment. The net growth in weight of water hycinth and water lettuce of 4 kg each in the 1.55 $m^2$ tanks for 22 days were 9.768 kg and 10.803 kg respectively, and those at initial weight of 6 kg each were 8.393 kg and 9.433 kg, respectively. The reason of lower net growth in the later group was restricted growth space. Nitrogen and phosphorus contents in water hyacinth were 2.89% and 0.27%, and those in water lettuce were 3.87% and 0.36%, respectively. Average quantities of removed N and P from 1.55 $m^2$ tanks by water hyacinth for 22 days were 18.9 g and 1.75 g, while those by water lettuce were 36.8 g and 3.5 g, respectively. Therefore water lettuce showed much higher efficiencies for removing both N and P from recirculating aquaculture water than water hyacinth.

Recirculating Aquaculture System Design and Water Treatment Analysis based on CFD Simulation

  • Juhyoung Sung;Sungyoon Cho;Wongi Jeon;Yangseob Kim;Kiwon Kwon;Deuk-young Jeong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.3083-3098
    • /
    • 2023
  • As demands for efficient and echo-friendly production of marine products increase, smart aquaculture based on information and communication technology (ICT) has become a promising trend. The smart aquaculture is expected to control fundamental farm environment variables including water temperature and dissolved oxygen (DO) levels with less human intervention. A recirculating aquaculture system (RAS) is required for the smart aquaculture which utilizes a purification tank to reuse water drained from the water tank while blocking the external environment. Elaborate water treatment should be considered to properly operate RAS. However, analyzing the water treatment performance is a challenging issue because fish farm circumstance continuously changes and recursively affects water fluidity. To handle this issue, we introduce computational fluid dynamics (CFD) aided water treatment analysis including water fluidity and the solid particles removal efficiency. We adopt RAS parameters widely used in the real aquaculture field to better reflect the real situation. The simulation results provide several indicators for users to check performance metrics when planning to select appropriate RAS without actually using it which costs a lot to operate.

Effective Trapping of Suspended Solids by Biofilter of Intensive Bioproduction Korean System

  • Kim, In-Bae;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.21 no.3
    • /
    • pp.181-183
    • /
    • 2008
  • It has been a very hard problem to reduce solids especially suspended solids (SS) in recirculating aquaculture systems. Present description is based on the performance of trapping SS by the biofilter of Intensive Bio-production Korean (IBK) system which is originally developed for nitrification. We found out that this filter has an excellent capability to remove SS in addition to nitrification. Filter element used here is corrugated plastic roofing plates readily available in the market, and cheaper than specially developed and patented products. It is easy to maintain the system, and requires low power consumption to operate for the treatment of a large amount of water. With 2 pumps of 5 hp each, about 500 $m^3$ of water is treated per hour. Flow speed in the filter was 2.6 mm/sec on average. This low flow speed and very large amount of water treated are the reasons for very effective trapping of fine SS. Upon single pass through this filter, 74.5% of total SS and 40% of non-settleable SS were removed. Wherever this filter is employed in recirculating fish farms water keeps high clarity, this having also been empirically ascertained.

Evaluation of Pollutant Load Unit Factor for Calculating Pollutants Emission in Aquacultural Farms (양식계 오염원 배출량 산정을 위한 원단위 설정)

  • Park, Jae Hong;Park, Bae Kyoung;Rhew, Doug Hee;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.656-665
    • /
    • 2013
  • This research was conducted to investigate pollutant load unit factor from aquacultural farms. Pollutant load unit factors were investigated on the 13 kinds of fish type, i.e., Trout, Leather Carp, Eel, Carp, Cartfish, Freshwater Eel, Crucian Carp, Colored Carp, Sturgeon, Marsh Snail, Sweetfish, Pond Snail, Eriocheir Sinensis. Water qualities in aquacultural farms were investigated wide range of values by fish type and pollutant items. High BOD and COD values were observed at the Leather Carp (Ponded water system), Cartfish (Ponded water system) and Freshwater Eel (Recirculating System). TOC and DOC values were relatively high at the Freshwater Eel (Recirculating System) and Eriocheir Sinensis (Extensive). Eel (Ponded water system) and Freshwater Eel (Recirculating System) produced high concentrated nutrient pollutants, i.e., T-N, T-P. Pollutant load unit factors are dependent on fish type, aquacultural type, water quality items, etc. If some fishes have similar basic unit values, those could be applied for TMDLs as a group of fish having same pollutant load unit. The water quality concentrations of post treatment facilities' (mainly reservoir tank) effluent were higher than those of fish raising bath because of extracting pollutant from sediment in the reservoir tank. Therefore, it needs to the management and regulations about post treatment facilities.

Serial Particle Size Fractionation and Water Quality in a Recirculating Aquaculture System for Eel

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.133-139
    • /
    • 2010
  • The effects of suspended solids size on culture water quality were determined in a commercial recirculating aquaculture system (RAS) for Japanese eel, Anguilla japonica. The particulate phase of the culture water was serially divided into six size fractions using 300, 200, 100, 75, 45, and 26 ${\mu}m$ pore size stainless sieves. The total, dissolved, and particulate nitrogen and phosphorus, and suspended solids for each fraction were determined. The concentration ranges in the fractions were: total nitrogen, 164-148 mg $L^{-1}$; total phosphorus, 20.4-15.5 mg $L^{-1}$; and total suspended solids, 8.1-6.1 mg $L^{-1}$. The concentration of total nitrogen and total phosphorus decreased significantly (P<0.05) with a 26 ${\mu}m$ and 200 ${\mu}m$ filter pore size, respectively. Nutrients from dissolved organic substances were much higher than from particulates. Analysis of particle size fractionation and its effects on water quality is useful to estimate removal efficiencies of a commercial effluent screening device for solid management and development of solid removal systems.

Design and Performance of a Laboratory Scale Closed Seawater Recirculating System for Korean Rockfish Sebastes schlegeli Culture Part 2. Performance of the Seawater Recirculating System

  • Lei Peng;Oh, Sung-Yong;Jo, Jae-Yoon
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.126-126
    • /
    • 2003
  • Performance of a laboratory scale closed seawater recirculating aquaculture system was evaluated. Twenty-kg Korean rockfish (130 fish) with an average body weight of 153.8 g was stocked. Over 107-day culture period, fish reached final density of 51.7 kg/m$^3$ (initial density, 33.3 kg/m$^3$) on the culture tank volume basis. On a daily basis, water addition was 3.4% of the total water volume in the system. Total ammonia nitrogen (TAN)concentrations were below 1 mg/L and nitrite nitrogen (NO$_2$-N) concentrations were within the range of 1-3 mg/L on most sampling days. TAN was removedin bead and sand filters and it was removed or produced in the sedimentation basin. Basically, NO$_2$-N was removed in the bead and sand filters while it was either removed or produced in the sedimentation basin. Nitrate nitrogen (NO$_3$-N) was produced in the bead filters and removed in the sand filter and sedimentation basin. Foam fractionator performed well in the recirculating system. The maximal daily removal values for total suspended solids (TSS) and protein were 10,9 g and 1.4 g, respectively. Whole water quality parameters were within the levels commonly recommendedfor fish culture on most of the sampling days. However, further studies are needed to evaluate the commercial feasibility of this system because of the small-scale system used in present experiment. At least, present study still provides some basic information for further studies of this kind of system.

  • PDF

Performance of a Lab-Scale Closed Seawater Recirculating System for Korean Rockfish Sebastes schlegeli Culture

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • v.25 no.4
    • /
    • pp.493-501
    • /
    • 2003
  • Performance of a laboratory scale closed seawater recirculating aquaculture system was evaluated. Twenty-kg of korean rockfish (130 fish) with an average body weight of 153.8g was stocked. Over a 107-day culture period, fish reached final density of $51.7kg/m^3$ (initial density, $33.3kg/m^3$) on the basis of the culture tank volume. On a daily basis, added water amounted to 3.4% of the total water volume in the system. Total ammonia nitrogen (TAN) concentrations were below 1mg/l and nitrite nitrogen $(NO_2-N)$ concentrations were within the range of 1-3mg/l on most sampling days. TAN was removed from bead and sand filters and it was removed or produced in the sedimentation basin. Basically, $NO_2-N$ was removed in the bead and sand filters, while it was either removed or produced in the sedimentation basin. Nitrate nitrogen $(NO_3-N)$ was produced in the bead filters and removed from the sand filter and sedimentation basin. The foam fractionator performed well in the recirculating system. The maximal daily removal values for total suspended solids (755) and protein were 10.9g and 1.4g, respectively. Whole water quality parameters were within the levels commonly recommended for fish culture on most of the sampling days. However, further studies are needed to evaluate the commercial feasibility of this system because of the smallscale system used in present experiment. At least, the present study still provides some basic information for further studies of this kind of system.