• Title/Summary/Keyword: Recharge volume

Search Result 21, Processing Time 0.026 seconds

Variation of Groundwater Level and Recharge Volume in Jeju Island (제주도 지하수위의 변화와 지하수 함양부피)

  • Park, Won-Bea;Kim, Gee-Pyo;Lee, Joon-Ho;Moon, Duk-Chul;Kim, Soo-Jeong;Koh, Gi-Won;Pang, Sung-Jun;Pang, Ig-Chan
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.857-872
    • /
    • 2011
  • The variation of groundwater level in Jeju Island is analyzed with the data of precipitation observed from 48 monitoring post and groundwater level observed from 84 monitoring wells during 2001 to 2009. The groundwater level rises in summer and falls in winter. The rise of groundwater level by precipitation is fast and small in the eastern region and slow and large in the western region. However, the speed of fall during the period of no rain is slower in the eastern region than in the western region. It tells that permeability is greater in the eastern region than in the western region. In this paper, we set up the base level of groundwater and calculate recharge volume between the base level and groundwater surface. During the period, the average recharge volume was $9.83{\times}10^9m^3$ and the maximum recharge volume was $2.667{\times}10^{10}m^3$ after the typhoon Nari. With these volume and the recharge masses obtained by applying the recharge ratio of 46.1%, estimated by Jeju Province (2003), the porous ratio over the whole Jeju Island is 16.8% in average and 4.6% in the case of maximum recharge volume just after typhoon Nari. A large difference in the two ratios is because that it takes time for groundwater permeated through the ground just after rain fall to fill up the empty porous part. Although the porous ratios over the whole Jeju Island obtained in this way has a large error, they give us the advantage to roughly estimate the amount of recharged groundwater mass directly from observing the groundwater level.

Study on the Determination of the Maximum Injection Pressure for Groundwater Rechargement (지하수 함양시 최대 주입압력 결정을 위한 연구)

  • Choi, Jin O;Jeong, Hyeon Cheol;Chung, Choong Ki;Kim, Chang Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.501-508
    • /
    • 2022
  • Required essential technique is to determine the maximum recharge pressure in the well with condition of non-ground failure for the recovery of the groundwater. Based on the classical soil mechanics, the maximum recharge pressure was estimated with the numerical anlaysis and laboratory triaxial test. In the numerical analysis, the maximum recharge pressure is defined as the ground failure stress. The ground failure of the sand was defined as the piping and the one of the caly was to the undrained failure by the confined pressure increment. In the triaxial test, the recharge pressure in the ground was modified by the back pressure in the specimen. In case of sand, the volume strain was dramatically increased at the 93 % of the maximum back pressure, same meaning of the 0 effective stress state. In case of clay, the only radial volume strain was to reached 1.5 % without failure. Therefore, The maximum recharge pressure could be determined with the numerical analysis and triaxial test.

Quantitative Assessment of Coastal Groundwater Vulnerability to Seawater Intrusion using Density-dependent Groundwater Flow Model (분산형 해수침투 모델을 이용한 양적 지표 기반의 해안지하수 취약성 평가연구)

  • Chang, Sun Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.95-105
    • /
    • 2021
  • Extensive groundwater abstraction has been recognized as one of the major challenges in management of coastal groundwater. The purpose of this study was to assess potential changes of groundwater distribution of northeastern Jeju Island over 10-year duration, where brackish water have been actively developed. To quantitatively estimate the coastal groundwater resources, numerical simulations using three-dimensional finite-difference density-dependent flow models were performed to describe spatial distribution of the groundwater in the aquifer under various pumping and recharge scenarios. The simulation results showed different spatial distribution of freshwater, brackish, and saline groundwater at varying seawater concentration from 10 to 90%. Volumetric analysis was also performed using three-dimensional concentration distribution of groundwater to calculate the volume of fresh, brackish, and saline groundwater below sea level. Based on the volumetric analysis, a quantitative analysis of future seawater intrusion vulnerability was performed using the volume-based vulnerability index adopted from the existing analytical approaches. The result showed that decrease in recharge can exacerbate vulnerability of coastal groundwater resources by inducing broader saline area as well as increasing brackish water volume of unconfined aquifers.

Assessing the impact of urbanization on runoff and non-point source pollution using the GIS L-THIA (GIS L-THIA를 이용한 도시화에 따른 유출과 비점원오염 영향 평가)

  • Yun, La-Young;Kim, Dong-Hui;Gwon, Hyeok-Hyeon;Sin, Seung-Cheol;Son, Kwang-Ik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1802-1806
    • /
    • 2006
  • It is important to consider the effects of land-use changes on surface runoff, stream flow, and groundwater recharge. Expansion of urban areas significantly impacts the environment in terms of ground water recharge, water pollution, and storm water drainage. Increase of impervious area due to urbanization leads to an increase in surface runoff volume, contributes to downstream flooding and a net loss in groundwater recharge. Assessment of the hydrologic impacts or urban land-use change traditionally includes models that evaluate how land use change alters peak runoff rates, and these results are then used in the design of drainage systems. Such methods however do not address the long-term hydrologic impacts of urban land use change and often do not consider how pollutants that wash off from different land uses affect water quality. L-THIA (Long-Term Hydrologic Impact Assessment) is an analysis tool that provides site-specific estimates of changes in runoff, recharge and non point source pollution resulting from past or proposed land-use changes. It gives long-term average annual runoff for a land use configuration, based on climate data for that area. In this study, the environmental and hydrological impact from the urbanized basin had been examined with GIS L-THIA in Korea.

  • PDF

A Note on Estimating and Managing Groundwater Reserves (지하수 부존량 평가와 관리에 대한 소고)

  • Lee, Byung Sun;Park, Jong Hwan;Myoung, Wooho;Son, Joohyeong;Lee, Sanghaw;Shim, Gyuseong;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • This study was conducted to estimate groundwater reserves within a designated depth. Three methods were applied to one representative county in southern Gyeongsang province, South Korea, to estimate the groundwater reserves in the aquifers. Estimated amounts of groundwater reserves in the region ranged from $20.2{\times}10^9m^3$ to $68.7{\times}10^9m^3$ (average $37.9{\times}10^9m^3$). Groundwater recharge obtained with a recharge ratio of 16.6% was $1.1{\times}10^9m^3/year$. Exploitable groundwater with an assumption of decadal-cycle minimal rainfall of 977.0 mm/year was approximated as 72% ($0.8{\times}10^9m^3/year$) of the total replenished water by recharge. The volume of recharge and exploitable water accounted for only 1.1% and 0.8% of groundwater reserves, respectively, which indicates substantial capacity of the reservoir to supply groundwater in an event of unexpected droughts. Nonetheless, each groundwater well should strictly comply with its allocated pumping rate to avoid alluvial groundwater depletion.

Preliminary Evaluation of the Optimal Injection Rate and Injection Efficiency of Groundwater Artificial Recharge Site Using Numerical Model (수치모델을 활용한 지하수 인공함양 대상지의 적정 주입량 및 주입효율 예비 평가)

  • Cha, Jang-Hwan;Kim, Gyoo-Bum;Lee, Jae Young
    • The Journal of Engineering Geology
    • /
    • v.31 no.1
    • /
    • pp.19-30
    • /
    • 2021
  • This study evaluated the injection rate and the injection efficiency of the artificial recharge in the upper drought-prone watershed region, where the remaining water was used for injection, by using a numerical model to secure water during a drought. As a result of a numerical model under the condition of diverse injection rates per a well and hydraulic characteristics of the aquifer, the optimal injection rate per a well was estimated as 50.0 ㎥/day, and the injection efficiency was simulated as 33.2% to 81.2% of the total injection volume. As the injection time was shorter, the injection efficiency tented to increase non-linearly. As the injection rate increased, the residual storage in aquifer increased and available groundwater amount also increased, which could be advantageous for drought relief. For a more accurate assessment of injection efficiency, the model will be validated using the field injection data and optimum scenarios will enable the efficient operation of the artificial recharge system in the study area.

A Study of the Variation of Runoff Characteristics Depending upon Installation of the Groundwater Recharge Facilities (인공함양시설 설치에 따른 유출특성 변화에 관한 연구)

  • Choi, Gye-Woon;Kim, Young-Kyu;Jeoung, Kee-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.27-34
    • /
    • 2004
  • In this paper, in order to analyse the variation of runoff characteristics depending upon installation of the groundwater recharge facilities, the experiment basin was prepared and the ratio of infiltration and runoff volume were observed in the rainfall events. For the rainfall analysis, 4 types of rainfall events were examined during July 11${\sim}$July 17, 2004. The results show that the mean ratio of infiltration was 89.39% and the mean ratio of runoff was 10.61%. For the artificial rainfall events, which are in the range of rainfall intensities between 60mm/hr and 100mm/hr, all the rainfall volume was infiltrated through the groundwater recharging basin. However, it is necessary to be careful for the long term rainfall, the runoff can be occurred based on the groundwater table.

Artifical Groundwater Recharge Using Underground Piping Method

  • Ahn, Sang-Jin;Lee, Jong-Hyong
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.11-29
    • /
    • 1992
  • Recently, rapid industrialization, urbanization and higher living standards accelerate to increase groundwater consumption resulting in continuously dropping groundwater elevations. To maintain enough groundwater volume without dropping groundwater elevations, the proper groundwater rechatge is necessary. The groundwater rechatge can be classified into two categories which are natural rechatge and artiticial rechatge. Even though the natural rechatge through by dired infiltration from the rainfall is desirable, the artificial groundwater rechatge is necessaty when the increment of groundwater consumption exceeds natural recharge rate. Well method and scattering method are utilized as artificial rechatging method, a severe disadvantage, which is the reduction of the void of soil surface, is indicated in the well method. Recently, the underground piping method, which is a scattering method, is receiving increasing attention as a proper recharging method. The method is indirectly to supply water to the underground using an underground piping system. Therefore, the void of soil surface is not severely reduced and better infiltration rate can be achieved. In this paper, the artificial groundwater rechatge using underground piping method is investigated through experiments and numerical analysis. The influence of the groundwater by underground piping method is evaluated through comparing recharging heights. Good agreements between experiments and numerical analysis are obtained and the artificial groundwater recharge by underground piping method is well tested and verified.

  • PDF

Sustainability of freshwater lens in small islands under climate change and increasing population

  • Babu, Roshina;Park, Namsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.145-145
    • /
    • 2019
  • Groundwater and rainwater are the only sources of freshwater in small islands as many islands lack surface water sources. Groundwater occurring in the form of freshwater lens floating on denser seawater is highly dependent on natural recharge from rainfall. A sharp interface numerical model for regional and well scale modeling is selected to assess the sustainability of freshwater lens in the island of Tongatapu. In this study, 29 downscaled General Circulation Model(GCM) predictions are input to the recharge model based on water balance modelling. Three GCM predictions which represent wet, dry and medium conditions are selected for use in the groundwater flow model. Total freshwater volume and number of saltwater intruded wells are simulated under various climate scenarios with GCM predicted rainfall pattern, sea level rise and pumping. Simulations indicate that the sustainability of the freshwater lens is threatened by the frequent droughts which are predicted under all scenarios of recharge. The natural depletion of the lens during droughts and increase in water demands, leads to saltwater upconing under the pumping wells. Implementation of drought management measures is of utmost importance to ensure sustainability of freshwater lens in future.

  • PDF

Rainwater Infiltration Characteristics in the Unsaturated Soil : Comparison of Finite Element Model with Experimental Results (불포화 토양에서 빗물의 침투특성 : 유한요소 모델과 실험결과 비교)

  • Yoo, Kun-Sun;Kim, Sang-Rae;Kim, Tschung-Il;Yoon, Hyun-Sik;Han, Moo-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.27-33
    • /
    • 2011
  • Infiltration plays an important role in the urban water cycle. Infiltration has a potential to contribute to groundwater recharge in addition to runoff reduction. However, infiltration in urban areas has been considered only as a means of runoff reduction. Conventional design methods for infiltration facilities assume soils to be fully-saturated for the sake of simplicity. The amount of groundwater recharge can not be estimated properly with this scheme. Hence, the characteristics of the unsaturated soil condition need to be considered. The finite element model using SEEP/W to estimate infiltration under the unsaturated condition is presented. Infiltration tests for Joomonjin sand are performed and the infiltration behavior of Joomoonjin sand under the unsaturated condition is measured experimentally to verify the validity of the finite element model. The results from comparing infiltrated volume between the saturated and the unsaturated conditions under the same soil and rainfall conditions show that the infiltrated volume in the unsaturated condition is two times bigger than that in the saturated condition.