• 제목/요약/키워드: Recess length

검색결과 64건 처리시간 0.016초

모악산도립공원 등산로의 환경훼손 실태 및 이용영향에 관한 조사연구 (Study on Environmental Deteriorations of Trail and Use Impacts in Moaksan Provincial Park)

  • 김세천;박종민
    • 한국조경학회지
    • /
    • 제25권4호
    • /
    • pp.39-50
    • /
    • 1998
  • The object of this study was to examine and analyze the environmental deterioration of three major trails and around peak area of Moaksan Provincial park in 1996. Trails are mostly made up at ridgeline and the slope of them is gentle. Mean trail width is 3.6m, and total length of branch trails is 982m in survey area. The environmental deterioration is derived from trail extension. Maximum eroded depth and cross-section area loss are 89cm and 14,050cm2 respectively, and gully erosion type appears at many sites. The environmental deterioration of trails is very heavy at the sections from Khui to Moaksan peak and from Moakchong to ascent part around the peak. The entire width, branch trail, maximum depth, cross-sectional area loss and surface roughness, as the indexes of trail conditions, are significantly greater at the more heavily used trails. Amount of erosion is influenced by eroded depth, longitudinal slope, runoff influence and entire width in descending order as well as the amount of use. Safety and protection facilities on the trail such as stone and soil stairs, rope handrail, stone channel and soil ditch work are built, but they are very deficient. Bared lands about 4,900m2 and fill slopes are caused and formed by recreation activities and constructions around peak area. It is required to carry the recess system and to conserve and rehabilitate the destroyed trail sites and bare fill slopes as soon as possible, before the environmental deterioration becomes critical because of increased used amount in consequence of construction of recreation parks.

  • PDF

Experimental Studies on Self-Oscillation of a Swirl Coaxial Injector

  • Kim, Dongjun;Wonho Jeong;Jihyuk Im;Youngbin Yoon
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.228-233
    • /
    • 2004
  • The spray and acoustic characteristics by the self-oscillation of a swirl coaxial injector were experimentally studied. The self-oscillation of a swirl coaxial injector is defined as pressure and flowrate oscillations by a time-delayed feedback between liquid and gas phase and has strong influences on atomization and mixing processes. Hence the occurrence and effect of the self-oscillation are measured using shadow photography technique, acoustic test and PDPA. The occurrence of self-oscillation largely depends on the injection conditions, such as pressure drop of liquid phase and relative momentum ratio. From the experimental results, self-oscillation occurs when the momentum of gas phase is enough large and the smaller the pressure drop of liquid phase is, the better self-oscillation occurs at the same momentum ratio. The self-oscillation is also affected by injector geometries, increasing the recess length results in the expansion of self-oscillation region and the increase of sound pressure level. The self-oscillation of a swirl coaxial injector accompanies a high intensity scream and this scream may provide harmful disturbances to combustion processes. Self-oscillation leads to strong changes in the drop size distribution and smoothly varies the slope of radial SMD distribution.

  • PDF

연소실 설계에 따른 실물형 가스발생기의 연소 안정성 특성 (Effect of Combustion Chamber Design on Combustion Stability Characteristics of a Full-scale Gas Generator)

  • 이광진;서성현;한영민;최환석;안규복
    • 한국추진공학회지
    • /
    • 제11권1호
    • /
    • pp.11-17
    • /
    • 2007
  • 연소실 설계에 따른 실물형 가스발생기의 연소 안정성 특성에 대한 실험적 연구가 수행되었다. 연소성능에 주요한 영향을 미치는 분사기 헤드에는 1.5의 리세스 수를 갖는 내부 혼합형 이중 스월 분사기 37개가 배치되었다. 본 논문에서는 연소실 길이, 직경, 그리고 교반링 등 연소실 설계 변경에 따른 연소 안정성 특성에 대하여 살펴보았다. 연소시험 결과 연소실의 유효 길이가 줄어듦에 따라 불안정 주파수는 고주파 영역에서 발생되며, 압력의 강도는 전반적으로 줄어들어 유해하지 않은 수준으로 감소가 가능하였다. 하지만 축방향 공진주파수에 해당하는 압력 섭동을 완전히 제거시키지는 못하는 것으로 판단된다.

강제교란 방법을 이용한 액체로켓엔진 연소기의 연소안정성 시험 (Combustion Stability Test of LRE Thrust Chamber using Artificial Perturbation Method)

  • 이광진;서성현;한영민;최환석;고영성
    • 한국추진공학회지
    • /
    • 제14권3호
    • /
    • pp.52-60
    • /
    • 2010
  • 이중와류 동축형 분사기가 사용된 추력 30톤급 액체로켓엔진 연소기의 연소안정성시험을 강제교란방법을 이용하여 국내 지상연소시험설비에서 수행하였다. 시험에는 분사기 리세스 수, 배플 길이, 막냉각 및 연소실 직경과 같은 설계 요소가 변경된 연소기가 사용되었으며 시험결과는 이 변수들이 액체로켓엔진 연소기의 고주파 연소안정성과 깊은 관계가 있음을 보여주었다. 강제교란에 의한 액체로켓엔진 연소기의 연소안정성 분석에 있어서 감쇠시간 대신 진동 감분을 사용한 결과로부터 감쇠인자의 증가는 액체로켓엔진 연소기의 고주파 연소안정성 향상에 영향을 미침을 확인하였다.